arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2410.19472physics.med-phcs.CE
收藏

患者特异性血管的几何不确定性及其对主动脉血流动力学的影响

Geometric Uncertainty of Patient-Specific Blood Vessels and its Impact on Aortic Hemodynamics

Domagoj Bošnjak, Richard Schussnig, Sascha Ranftl, Gerhard A. Holzapfel, Thomas-Peter Fries

AI总结:

本研究通过高斯随机场扰动患者特异性主动脉网格,结合弹性算子扩展和大量血流模拟,量化了局部几何不确定性对流量和壁面剪切应力等血流动力学指标的影响,发现适度扰动下误差在个位数百分比内,但梯度相关量更敏感。

摘要:

在血管系统数值模拟的背景下,由于模型复杂性和相关的大量数值计算工作量,局部几何不确定性尚未得到足够详细的研究。这些不确定性与由计算机断层扫描成像、分割和网格生成导致的几何建模误差相关。本工作提出了一种系统性地诱导局部修改并执行足够数量的血流模拟的方法,以对最常用的关注量(如流量或壁面剪切应力)得出统计上相关的结论。通过由高斯随机场定义的位移图扰动患者特异性主动脉的结构化六面体网格表面,以随机建模边界的局部不确定性。研究了三种不同情况,平均扰动幅度分别为0.25、0.5和1.0毫米。通过弹性算子将表面扰动扩展到内部,构建有效、局部扰动的网格。否则,在这些网格上求解相同的不可压缩流动问题,考虑生理边界条件和Carreau流体参数。针对三种不同的扰动情况,执行了约300,000次三维非定常血流模拟,以估计关注量的概率分布。收敛性研究证明了所用网格的空间分辨率。总体而言,结果表明适度的几何扰动导致关注量具有合理的工程精度(相对误差在个位数百分比范围内),梯度相关测量具有更高的敏感性,但观察到的误差不可忽略。

英文摘要:

In the context of numerical simulations of the vascular system, local geometric uncertainties have not yet been examined in sufficient detail due to model complexity and the associated large numerical effort. Such uncertainties are related to geometric modeling errors resulting from computed tomography imaging, segmentation and meshing. This work presents a methodology to systematically induce local modifications and perform a sufficient number of blood flow simulations to draw statistically relevant conclusions on the most commonly employed quantities of interest, such as flow rates or wall shear stress. The surface of a structured hexahedral mesh of a patient-specific aorta is perturbed by displacement maps defined via Gaussian random fields to stochastically model the local uncertainty of the boundary. Three different cases are studied, with the mean perturbation magnitude of $0.25$, $0.5$ and $1.0~$mm. Valid, locally perturbed meshes are constructed via an elasticity operator that extends surface perturbations into the interior. Otherwise, identical incompressible flow problems are solved on these meshes, taking physiological boundary conditions and Carreau fluid parameters into account. Roughly $300\,000$ three-dimensional non-stationary blood flow simulations are performed for the three different perturbation cases to estimate the probability distributions of the quantities of interest. Convergence studies justify the spatial resolution of the employed meshes. Overall, the results suggest that moderate geometric perturbations result in reasonable engineering accuracy (relative errors in single-digit percentage range) of the quantities of interest, with higher sensitivity for gradient-related measures, noting that the observed errors are not negligible.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑