评估组织工程血管移植物位移的血流动力学影响:结合术后体内结果和计算建模以改进手术规划

Assessing Hemodynamic Impact of Tissue-Engineered Vascular Graft Displacement: Combining Postoperative in vivo Results and Computational Modeling to Improve Surgical Planning

Johns Hopkins University(约翰斯·霍普金斯大学);Children’s Hospital of Philadelphia(费城儿童医院);University of Wisconsin–Madison(威斯康星大学麦迪逊分校);Baltimore Polytechnic Institute(巴尔的摩理工学院);Children's National Hospital(国家儿童医疗中心);University of Chicago Medical Center(芝加哥大学医学中心);Illinois Institute of Technology(伊利诺伊理工学院);Nanofiber Solutions(纳米纤维解决方案公司)
Seda Aslan, Enze Chen, Miya Mese-Jones, Jacqueline Contento, Hidenori Hayashi, Keigo Kawaji, Joey Huddle, Jed Johnson, Yue-Hin Loke, Mark Fuge, Laura Olivieri, … 展开作者

Seda Aslan, Enze Chen, Miya Mese-Jones, Jacqueline Contento, Hidenori Hayashi, Keigo Kawaji, Joey Huddle, Jed Johnson, Yue-Hin Loke, Mark Fuge, Laura Olivieri, Thao D Nguyen, Narutoshi Hibino, Axel Krieger

AI总结:

本研究通过结合体内结果和计算建模,评估TEVG位移和大小对血流动力学的影响,以改进手术规划。

摘要:

组织工程血管移植物(TEVG)在血管重建中显示出前景。然而,精确的体内植入具有挑战性,不清楚位置和大小的偏差如何影响血流动力学。本研究旨在通过一项体内研究比较术前设计和术后解剖结构,以评估差异并研究移植物位移和大小对血流动力学的影响。通过虚拟模拟植入场景(这些场景由体内术后结果指导),比较了四只猪主动脉的设计和术后几何结构,以测量植入位置和移植物形状的不匹配。这些结果指导了一项虚拟的TEVG植入研究。TEVG的位置、方向和大小被改变,以研究其对最终主动脉形状和血流动力学的影响。使用有限元建模模拟TEVG的吻合。关键血流动力学指标通过虚拟植入和实际术后解剖使用计算流体动力学获得。我们的体内研究显示,TEVG可经历高达6.9毫米的位移和38度的旋转位移,导致压力降(2.5 mmHg,50%)和时间平均壁剪切应力(7.2 Pa,72%)的差异。虚拟吻合模拟将主动脉形状预测改进了27.5%。我们的结果突显了关键血流动力学指标对移植物植入位置和大小不匹配的敏感性。通过量化位移范围及其在手术中的影响,外科医生可以做出明智的决策。

英文摘要:

Tissue-engineered vascular grafts (TEVG) have shown promise in advancing vascular reconstructions. However, precise in vivo implantation is challenging, and it is unclear how deviations in location and size affect hemodynamics. This study aims to compare preoperative designs and postoperative anatomies of TEVG in an in vivo study to evaluate discrepancies and investigate the impact of graft displacement and size on hemodynamics by virtually simulating implantation scenarios that are informed by in vivo postoperative results. Designed and postoperative geometries of four porcine aortas were compared to measure the mismatch in implantation location and graft shape. These results informed a virtual TEVG implantation study. TEVG location, orientation, and size were varied to investigate the effects on the final aorta shape and hemodynamics. Anastomosis of TEVG was simulated using finite element modeling. Key hemodynamic metrics were obtained from virtual implantations and actual postoperative anatomies using computational fluid dynamics. Our in vivo study showed that TEVGs can experience up to 6.9 mm displacement and a 38 degree rotational shift post-implantation, leading to discrepancies in pressure drop (2.5 mmHg, 50%) and time-averaged wall shear stress (7.2 Pa, 72%) compared to predictions. Virtual anastomosis simulations improved aortic shape predictions by 27.5%. Our results highlight the sensitivity of key hemodynamic metrics to graft implantation location and size mismatch. By quantifying displacement ranges and their impacts during surgery, surgeons can make informed decisions.