胸主动脉腔内修复术中覆膜支架导引鞘的血流动力学效应

Hemodynamic effects of stent-graft introducer sheath during thoracic endovascular aortic repair

Yonghui Qiao, Le Mao, Yan Wang, Jingyang Luan, Yanlu Chen, Ting Zhu, Kun Luo, Jianren Fan

摘要:

胸主动脉腔内修复术(TEVAR)已成为各种主动脉病变的标准治疗方法。本研究旨在评价TEVAR期间覆膜支架导入鞘的血流动力学效应。设计了三个理想化的代表性病变动脉瘤、主动脉缩窄和主动脉夹层。计算流体动力学研究在上述理想化的主动脉几何形状中进行。将临床常规使用的导引鞘虚拟输送到患病动脉中。进行对比分析以评价导引鞘的血流动力学效应。结果表明,由于导引鞘的阻塞,主动脉上分支的血流量将增加9%以上。暴露于高内皮细胞活化电位(ECAP)的区域在主动脉缩窄和主动脉夹层的情况下扩大,这表明TEVAR期间血栓形成的概率可能增加。收缩期峰值压力明显升高,舒张早期无此现象。主动脉弓和降主动脉中的血液粘度被导引鞘显著改变。不均匀的粘度分布证实了使用非牛顿模型的必要性,并且具有高ECAP的高粘度区域进一步促进血栓形成。我们的结果强调了覆膜支架导入鞘在TEVAR期间的血流动力学效应,这可能与围手术期并发症有关。

英文摘要:

Thoracic endovascular aortic repair (TEVAR) has become the standard treatment of a variety of aortic pathologies. The objective of this study is to evaluate the hemodynamic effects of stent-graft introducer sheath during TEVAR. Three idealized representative diseased aortas of aortic aneurysm, coarctation of the aorta, and aortic dissection were designed. Computational fluid dynamics studies were performed in the above idealized aortic geometries. An introducer sheath routinely used in the clinic was virtually-delivered into diseased aortas. Comparative analysis was carried out to evaluate the hemodynamic effects of the introducer sheath. Results show that the blood flow to the supra-aortic branches would increase above 9% due to the obstruction of the introducer sheath. The region exposed to high endothelial cell activation potential (ECAP) expands in the scenarios of coarctation of the aorta and aortic dissection, which indicates that the probability of thrombus formation may increase during TEVAR. The pressure magnitude in peak systole shows an obvious rise and a similar phenomenon is not observed in early diastole. The blood viscosity in the aortic arch and descending aorta is remarkably altered by the introducer sheath. The uneven viscosity distribution confirms the necessity of using non-Newtonian models and high viscosity region with high ECAP further promotes thrombosis. Our results highlight the hemodynamic effects of stent-graft introducer sheath during TEVAR, which may associate with perioperative complications.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑