流体结构相互作用:胸主动脉腔内修复术后覆膜支架的生物力学意义

Fluid structure interaction: Insights into biomechanical implications of endograft after thoracic endovascular aortic repair

Yonghui Qiao, Le Mao, Ying Ding, Ting Zhu, Kun Luo, Jianren Fan

摘要:

胸主动脉腔内修复术(TEVAR)已发展成为主动脉疾病最有效的治疗方法。本研究旨在评价TEVAR后植入覆膜支架的生物力学意义。我们提出了一种新的基于图像的,患者特定的,流体结构的计算框架。基于临床图像重建血液、覆膜支架和主动脉壁的几何形状。收集患者特异性测量数据以确定三要素Windkessel的参数。我们分别设计了刚性壁假设、血液-壁相互作用、血液-覆膜支架-壁相互作用的三种术后场景,其中应用双向流体-结构相互作用(FSI)方法预测复合支架-壁的变形。计算结果与多普勒超声数据进行了验证。结果表明,刚性壁假设不能预测流出血液和能量损失(EL)的波形。FSI方法捕捉到了血流能量储存和释放的全过程,包括四个阶段。覆膜支架植入会削弱主动脉的缓冲功能,使平均EL降低19.1%。室壁压力与主动脉容积的闭合曲线面积可反映血流与室壁变形相互作用所产生的电致应变,占总电致应变的68.8%。FSI和覆膜支架均对壁面剪切应力相关指数产生轻微影响。复合支架壁区域的可变形性明显受到覆膜支架的限制。我们的结果强调了考虑血流、植入的覆膜支架和主动脉壁之间相互作用的重要性,以在TEVAR后计算研究中获得生理学上准确的血流动力学,主动脉壁的变形是血流主要EL的原因。

英文摘要:

Thoracic endovascular aortic repair (TEVAR) has developed to be the most effective treatment for aortic diseases. This study aims to evaluate the biomechanical implications of the implanted endograft after TEVAR. We present a novel image-based, patient-specific, fluid-structure computational framework. The geometries of blood, endograft, and aortic wall were reconstructed based on clinical images. Patient-specific measurement data was collected to determine the parameters of the three-element Windkessel. We designed three postoperative scenarios with rigid wall assumption, blood-wall interaction, blood-endograft-wall interplay, respectively, where a two-way fluid-structure interaction (FSI) method was applied to predict the deformation of the composite stent-wall. Computational results were validated with Doppler ultrasound data. Results show that the rigid wall assumption fails to predict the waveforms of blood outflow and energy loss (EL). The complete storage and release process of blood flow energy, which consists of four phases is captured by the FSI method. The endograft implantation would weaken the buffer function of the aorta and reduce mean EL by 19.1%. The closed curve area of wall pressure and aortic volume could indicate the EL caused by the interaction between blood flow and wall deformation, which accounts for 68.8% of the total EL. Both the FSI and endograft have a slight effect on wall shear stress-related-indices. The deformability of the composite stent-wall region is remarkably limited by the endograft. Our results highlight the importance of considering the interaction between blood flow, the implanted endograft, and the aortic wall to acquire physiologically accurate hemodynamics in post-TEVAR computational studies and the deformation of the aortic wall is responsible for the major EL of the blood flow.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑