Blood pressure (BP) changes are linked to individual health status in both clinical and non-clinical settings. This study developed a deep learning model to classify systolic (SBP), diastolic (DBP), and mean (MBP) BP changes using photoplethysmography (PPG) waveforms. Data from the Vital Signs Database (VitalDB) comprising 1,005 ICU patients with synchronized PPG and BP recordings was used. BP changes were categorized into three labels: Spike (increase above a threshold), Stable (change within a plus or minus threshold), and Dip (decrease below a threshold). Four time-series classification models were studied: multi-layer perceptron, convolutional neural network, residual network, and Encoder. A subset of 500 patients was randomly selected for training and validation, ensuring a uniform distribution across BP change labels. Two test datasets were compiled: Test-I (n=500) with a uniform distribution selection process, and Test-II (n=5) without. The study also explored the impact of including second-deviation PPG (sdPPG) waveforms as additional input information. The Encoder model with a Softmax weighting process using both PPG and sdPPG waveforms achieved the highest detection accuracy--exceeding 71.3% and 85.4% in Test-I and Test-II, respectively, with thresholds of 30 mmHg for SBP, 15 mmHg for DBP, and 20 mmHg for MBP. Corresponding F1-scores were over 71.8% and 88.5%. These findings confirm that PPG waveforms are effective for real-time monitoring of BP changes in ICU settings and suggest potential for broader applications.
Synergistic Blood Pressure Estimation via Contactless mmWave Radar and Imaging Photoplethysmography: A Feasibility Study
Glasgow College, University of Electronic Science and Technology of China(格拉斯哥学院,电子科技大学);School of Life Science and Technology, University of Electronic Science and Technology of China(生命科学与技术学院,电子科技大学);Graduate School of Informatics and Engineering, The University of Electro-Communications(信息工程研究生院,电气通信大学);Yangtze Delta Region Institute (Huzhou), University of Electronic Science and Technology of China(长三角研究院(湖州),电子科技大学)
Smartwatch Photoplethysmography-Derived Heart Age via ECG-Guided Cross-Modal Pretraining as a Digital Biomarker of Vascular Aging
National Institute of Health Data Science, Peking University(北京大学健康医疗大数据科学国家研究院);Institute of Medical Technology, Peking University Health Science Center(北京大学医学部医药技术学院);OPPO Health Lab(OPPO健康实验室);School of Intelligence Science and Technology, Peking University(北京大学智能科学学院);Xidian University(西安电子科技大学);Shenzhen Technology University(深圳职业技术大学)
Generalizable Blood Pressure Estimation from Multi-Wavelength PPG Using Curriculum-Adversarial Learning
Department of Computer Science, University of California, Davis(加州大学戴维斯分校计算机科学系);Department of Electrical and Computer Engineering, University of California, Davis(加州大学戴维斯分校电气与计算机工程系)
Machine-learning for photoplethysmography analysis: Benchmarking feature, image, and signal-based approaches
Carl von Ossietzky Universität Oldenburg(奥尔登堡卡尔·冯·奥西特齐大学);Laboratoire national de métrologie et d’essais(国家计量与测试实验室);Biomedical Engineering Institute, Kaunas University of Technology(克莱萨斯理工大学生物医学工程研究所);Physikalisch-Technische Bundesanstalt(德国物理技术部);National Physical Laboratory(国家物理实验室);King’s College London(伦敦国王学院);University of Surrey(萨里大学);Department of Public Health and Primary Care, University of Cambridge(剑桥大学公共卫生与初级保健系)
Change Point--Aware Evaluation and Re-Calibration of PPG-Based Blood Pressure Estimation
VUNO Inc.(VUNO公司);University of California, Irvine(加州大学欧文分校);Research Institute for Future Medicine, Samsung Medical Center(三星未来医学研究所);Inha University Hospital(仁荷大学医院)
TransfoRhythm: A Transformer Architecture Conductive to Blood Pressure Estimation via Solo PPG Signal Capturing
Faculty of Computer Science(计算机科学学院);Concordia Institute for Information Systems Engineering(康考迪亚信息系统工程学院);University of New Brunswick(新不伦瑞克大学);Concordia University(康考迪亚大学)
Cuffless Blood Pressure Estimation from Six Wearable Sensor Modalities in Multi-Motion-State Scenarios
Faculty of Frontier Sciences, Harbin Institute of Technology, Shenzhen(前沿科学学院,哈尔滨工业大学深圳校区);University of Melbourne(墨尔本大学);University of New South Wales(新南威尔士大学)
Benchmarking and Enhancing PPG-Based Cuffless Blood Pressure Estimation Methods
Department of Engineering Technology, University of Houston, Texas, USA(工程科技系,休斯顿大学,德克萨斯州,美国);Department of Electrical and Computer Engineering, University of Houston, Texas, USA(电气与计算机工程系,休斯顿大学,德克萨斯州,美国);Department of Information Science Technology, University of Houston, Texas, USA(信息科学科技系,休斯顿大学,德克萨斯州,美国);Department of Cardiovascular Surgery, Houston Methodist Hospital, Texas, USA(心血管外科系,休斯顿方法医院,德克萨斯州,美国);Department of Biomedical Engineering, University of Houston, Texas, USA(生物医学工程系,休斯顿大学,德克萨斯州,美国)
Rapid Adaptation of SpO2 Estimation to Wearable Devices via Transfer Learning on Low-Sampling-Rate PPG
Department of Computer Science, University of California, Davis(加州大学戴维斯分校计算机科学系);Department of Electrical and Computer Engineering, University of California, Davis(加州大学戴维斯分校电气与计算机工程系)
Unexpected sawtooth artifact in beat-to-beat pulse transit time measured from patient monitor data
Taipei Veteran General Hospital(台北荣民总医院);Chang Gung Memorial Hospital(长庚纪念医院);Chang Gung University(长庚大学);University of Washington(华盛顿大学);Duke University(杜克大学);National Center for Theoretical Sciences(理论科学研究中心)
Deriving Health Metrics from the Photoplethysmogram: Benchmarks and Insights from MIMIC-III-Ext-PPG
AI4Health Department, Oldenburg University(AI4Health部门,旧恩斯特堡大学);Department of Data Science and AI, National Physical Laboratory(数据科学与人工智能系,国家物理实验室);School of Mathematics and Physics, University of Surrey(数学与物理学院,萨里大学);Department of Public Health and Primary Care, University of Cambridge(公共卫生与初级保健系,剑桥大学)