arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2407.03274eess.SP
收藏

利用光电容积脉搏波描记法通过免校准深度学习模型检测实时血压变化

Using Photoplethysmography to Detect Real-time Blood Pressure Changes with a Calibration-free Deep Learning Model

Jingyuan Hong, Manasi Nandi, Weiwei Jin, Jordi Alastruey

AI总结:

本研究利用PPG波形和免校准深度学习模型对ICU患者收缩压、舒张压和平均压的实时变化进行分类,Encoder模型结合sdPPG波形在两项测试中准确率分别超过71.3%和85.4%,验证了PPG用于实时血压变化监测的有效性。

摘要:

血压(BP)变化在临床和非临床环境中都与个体健康状况相关。本研究开发了一种深度学习模型,利用光电容积脉搏波描记法(PPG)波形对收缩压(SBP)、舒张压(DBP)和平均压(MBP)的变化进行分类。数据来自生命体征数据库(VitalDB),包含1,005名ICU患者同步采集的PPG和BP记录。血压变化被分为三个标签:Spike(升高超过阈值)、Stable(变化在正负阈值范围内)和Dip(降低超过阈值)。研究了四种时间序列分类模型:多层感知机、卷积神经网络、残差网络和Encoder。随机选取500名患者的子集用于训练和验证,确保各血压变化标签均匀分布。构建了两个测试数据集:Test-I(n=500)采用均匀分布选择过程,Test-II(n=5)不采用。研究还探索了加入二阶差分PPG(sdPPG)波形作为额外输入信息的影响。采用Softmax加权过程的Encoder模型同时使用PPG和sdPPG波形,取得了最高的检测准确率——在Test-I和Test-II中分别超过71.3%和85.4%,所用阈值为SBP 30 mmHg、DBP 15 mmHg、MBP 20 mmHg。相应的F1分数分别超过71.8%和88.5%。这些发现证实PPG波形在ICU环境中对血压变化的实时监测是有效的,并提示其具有更广泛应用的潜力。

英文摘要:

Blood pressure (BP) changes are linked to individual health status in both clinical and non-clinical settings. This study developed a deep learning model to classify systolic (SBP), diastolic (DBP), and mean (MBP) BP changes using photoplethysmography (PPG) waveforms. Data from the Vital Signs Database (VitalDB) comprising 1,005 ICU patients with synchronized PPG and BP recordings was used. BP changes were categorized into three labels: Spike (increase above a threshold), Stable (change within a plus or minus threshold), and Dip (decrease below a threshold). Four time-series classification models were studied: multi-layer perceptron, convolutional neural network, residual network, and Encoder. A subset of 500 patients was randomly selected for training and validation, ensuring a uniform distribution across BP change labels. Two test datasets were compiled: Test-I (n=500) with a uniform distribution selection process, and Test-II (n=5) without. The study also explored the impact of including second-deviation PPG (sdPPG) waveforms as additional input information. The Encoder model with a Softmax weighting process using both PPG and sdPPG waveforms achieved the highest detection accuracy--exceeding 71.3% and 85.4% in Test-I and Test-II, respectively, with thresholds of 30 mmHg for SBP, 15 mmHg for DBP, and 20 mmHg for MBP. Corresponding F1-scores were over 71.8% and 88.5%. These findings confirm that PPG waveforms are effective for real-time monitoring of BP changes in ICU settings and suggest potential for broader applications.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑