arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2512.01653eess.SPcs.LG

无袖带血压估计:基于六种可穿戴传感器模态在多运动状态场景中的应用

Cuffless Blood Pressure Estimation from Six Wearable Sensor Modalities in Multi-Motion-State Scenarios

Faculty of Frontier Sciences, Harbin Institute of Technology, Shenzhen(前沿科学学院,哈尔滨工业大学深圳校区);University of Melbourne(墨尔本大学);University of New South Wales(新南威尔士大学)

Yiqiao Chen, Fazheng Xu, Zijian Huang, Juchi He, Zhenghui Feng

AI总结:

本文提出了一种基于六种可穿戴传感器模态的无袖带血压估计框架,通过联合利用ECG、PPG、压力、温度和运动传感器数据,实现多运动状态下的血压准确估计。

摘要:

心血管疾病(CVD)是全球发病率和死亡率的主要原因,持续性高血压是一种常被忽视的风险因素,因此使用可穿戴设备进行无袖带连续血压(BP)监测对于早期筛查和长期管理至关重要。大多数现有的无袖带血压估计方法仅使用光体积脉搏波形图(PPG)和心电图(ECG)信号,单独或组合使用。这些模型通常是在静止或近静态条件下开发的,并在多运动状态场景中难以保持稳健的准确性。在本研究中,我们提出了一种六种模态的血压估计框架,该框架联合利用ECG、多通道PPG、贴附压力、传感器温度以及三轴加速度计和角速度。每种模态通过轻量级分支编码器处理,对比学习强制跨模态语义对齐,混合专家(MoE)回归头适应性地将融合特征映射到血压上,以适应不同运动状态。在公共脉搏传导时间PPG数据集上进行了全面实验,该数据集包含来自22名受试者的跑步、步行和坐姿数据。实验结果显示,所提出的方法在收缩压(SBP)上的均方误差(MAE)为3.60 mmHg,在舒张压(DBP)上的MAE为3.01 mmHg。从临床角度来看,根据英国高血压协会(BHS)协议,其在SBP、DBP和平均动脉压(MAP)上达到A级,并满足美国医学仪器协会(AAMI)标准中关于平均误差(ME)和误差标准差(SDE)的数值要求。

英文摘要:

Cardiovascular disease (CVD) is a leading cause of morbidity and mortality worldwide, and sustained hypertension is an often silent risk factor, making cuffless continuous blood pressure (BP) monitoring with wearable devices important for early screening and long-term management. Most existing cuffless BP estimation methods use only photoplethysmography (PPG) and electrocardiography (ECG) signals, alone or in combination. These models are typically developed under resting or quasi-static conditions and struggle to maintain robust accuracy in multi-motion-state scenarios. In this study, we propose a six-modal BP estimation framework that jointly leverages ECG, multi-channel PPG, attachment pressure, sensor temperature, and triaxial acceleration and angular velocity. Each modality is processed by a lightweight branch encoder, contrastive learning enforces cross-modal semantic alignment, and a mixture-of-experts (MoE) regression head adaptively maps the fused features to BP across motion states. Comprehensive experiments on the public Pulse Transit Time PPG Dataset, which includes running, walking, and sitting data from 22 subjects, show that the proposed method achieves mean absolute errors (MAE) of 3.60 mmHg for systolic BP (SBP) and 3.01 mmHg for diastolic BP (DBP). From a clinical perspective, it attains Grade A for SBP, DBP, and mean arterial pressure (MAP) according to the British Hypertension Society (BHS) protocol and meets the numerical criteria of the Association for the Advancement of Medical Instrumentation (AAMI) standard for mean error (ME) and standard deviation of error (SDE).

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑