耳内血氧饱和度测定:一种检测COVID-19迟发性危及生命的低氧血症的动态工具
In-Ear Measurement of Blood Oxygen Saturation: An Ambulatory Tool Needed To Detect The Delayed Life-Threatening Hypoxaemia in COVID-19
摘要:
血氧饱和度的非侵入性动态估计已成为在COVID-19感染后延迟阶段检测低氧血症的重要临床要求,其中在没有主观呼吸困难的情况下可能发生危险的缺氧。这种直接的临床驱动力,加上对更个性化健康数据的普遍追求,意味着在不久的将来,毛细血管血氧饱和度(SpO 2)的脉搏血氧测量可能会扩展到可穿戴健康技术的临床和消费者市场。在本研究中,我们着手确定从耳道测量SpO 2作为长期监测的便利部位的可行性,并与右手食指-常规临床测量部位进行全面比较。在静息SpO 2估计过程中,我们发现两个测量部位之间的均方根差为1.47%,右耳道中SpO 2的平均差为0.23%。通过在屏气期间同时记录右耳道和食指的脉搏血氧饱和度,我们观察到耳朵和手指之间的反应时间有实质性改善,所有受试者的平均值为12.4秒,范围为4.2 - 24.2秒。影响这种反应时间的因素,称为SpO 2延迟,如受试者的性别也进行了探讨。此外,我们研究了耳道血氧饱和度测量的潜在缺点,即较低的光电容积描记图幅度,并提出了减轻这一缺点的方法。这些结果与之前发现的优点(如对温度的鲁棒性)结合在一起,使得从耳道测量SpO 2的情况既方便又优于传统的手指测量部位,从而在临床和日常生活环境中进行连续的非侵入性长期监测。
英文摘要:
Non-invasive ambulatory estimation of blood oxygen saturation has emerged as an important clinical requirement to detect hypoxemia in the delayed post-infective phase of COVID-19, where dangerous hypoxia may occur in the absence of subjective breathlessness. This immediate clinical driver, combined with the general quest for more personalised health data, means that pulse oximetry measurement of capillary oxygen saturation (SpO2) will likely expand into both the clinical and consumer market of wearable health technology in the near future. In this study, we set out to establish the feasibility of SpO2 measurement from the ear canal as a convenient site for long term monitoring, and perform a comprehensive comparison with the right index finger - the conventional clinical measurement site. During resting SpO2 estimation, we found a root mean square difference of 1.47% between the two measurement sites, with a mean difference of 0.23% higher SpO2 in the right ear canal. Through the simultaneous recording of pulse oximetry from both the right ear canal and index finger during breath holds, we observe a substantial improvement in response time between the ear and finger that has a mean of 12.4 seconds and a range of 4.2 - 24.2 seconds across all subjects. Factors which influence this response time, termed SpO2 delay, such as the sex of a subject are also explored. Furthermore, we examine the potential downsides of ear canal blood oxygen saturation measurement, namely the lower photoplethysmogram amplitude, and suggest ways to mitigate this disadvantage. These results are presented in conjunction with previously discovered benefits such as robustness to temperature, making the case for measurement of SpO2 from the ear canal being both convenient and superior to conventional finger measurement sites for continuous non-intrusive long term monitoring in both clinical and everyday-life settings.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。