腹主动脉瘤治疗中传统血管内器械的特性研究

Characterization of Conventional Endovascular Devices in Treatment of Abdominal Aortic Aneurysms

Yara Alawneh, James J. Zhou, Alykhan Sewani, Andrew Dueck, M. Ali Tavallaei

AI总结:

本研究利用患者CT图像构建AAA模型,在X射线透视下对比了传统不可操纵与可操纵导管在EVAR手术中的可达工作空间和接口插管表现,发现可操纵导管在复杂解剖中心区域更具优势,而不可操纵导管更适用于外围区域,为器械选择与设计提供了系统量化依据。

摘要:

腹主动脉瘤(AAA)通常通过一种被称为EVAR的血管内介入方法进行修复。这些复杂手术的成功与否及持续时间,主要取决于导航相应介入器械的准确性和可靠性。本研究调查了传统不可操纵和可操纵导管在血管内动脉瘤修复(EVAR)手术中的表现,重点关注两个主要指标:可达工作空间和接口插管成功率。我们利用患者CT图像开发了两个腹主动脉瘤(AAA)模型用于实验。在X射线透视引导下,我们量化了可达工作空间,并记录了不可操纵和可操纵导管的接口插管成功率、插管时间和透视时间,随后进行了比较。我们未能观察到两种导管在总体插管成功率或透视时间上存在统计学上的显著差异。然而,在具有挑战性的解剖场景中(特别是更具挑战性的接口位置),可操纵导管在成功率和插管时间上表现出统计学上的显著优势。虽然考虑整个动脉瘤时,不可操纵和可操纵导管在可达工作空间上没有统计学差异,但分段分析表明,可操纵导管在中心区域表现更好,而不可操纵导管在外围区域表现更佳。本研究提供了一种量化血管内器械性能的系统方法。研究结果表明,尽管可操纵导管在复杂解剖条件下可能具有优势,但不可操纵导管更适用于动脉瘤的外围区域。这些见解可为EVAR中的导管选择提供参考,并可能影响器械设计和临床实践。

英文摘要:

Abdominal Aortic Aneurysms (AAA) are often repaired through an Endovascular approach known as EVAR. The success and duration of these challenging procedures are primarily attributable to the accuracy and reliability of navigating corresponding interventional devices. This study investigates the performance of conventional non-steerable and steerable catheters in endovascular aneurysm repair (EVAR) procedures, focusing on two primary metrics: reachable workspace and gate cannulation success. We developed two abdominal aortic aneurysm (AAA) phantoms using patient CT images for our experiments. Under X-ray fluoroscopy guidance, the reachable workspace was quantified, and gate cannulation success rates, cannulation time, and fluoroscopy times were recorded for both non-steerable and steerable catheters and were compared. We were unable to observe statistically significant differences between the two catheter types in overall cannulation success rates or fluoroscopy time. However, in challenging anatomical scenarios (particularly a more challenging gate location), the steerable catheter showed statistically significant advantages in success rates and cannulation times. While there were no statistical differences in reachable workspace between non-steerable and steerable catheters when considering the whole aneurysm, segmented analysis showed that the steerable catheter performed better in the central region, and non-steerable catheters performed better in the peripheral region. This study provides a systematic method for quantifying the performance of endovascular devices. The findings suggest that while steerable catheters may offer advantages in complex anatomical conditions, non-steerable catheters are preferable in peripheral areas of the aneurysm. These insights can inform catheter selection in EVAR, potentially influencing device design and clinical practice.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑