arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2402.13838physics.flu-dyn
收藏

中性浮力漏电介质液滴内部的电流体动力学流动

Electrohydrodynamic flows inside a neutrally buoyant leaky dielectric drop

Joel R. Karp, Bertrand Lecordier, Mostafa S. Shadloo

AI总结:

首次实验研究中性浮力漏电介质液滴内部EHD流动,通过PIV和高速成像测量内部环流与速度分布,分析扁平和长椭球构型,提出临界电毛细数0.1,完善小变形下LDM适用性并揭示大变形特性。

摘要:

我们首次对初始半径为2.25 mm的中性浮力液滴内部的电流体动力学(EHD)流动进行了实验研究。利用粒子图像测速(PIV)和高速阴影成像技术,我们测量了液滴内部的环流,并报告了液滴本体和界面处的速度分布。采用两种漏电介质液体(硅油和蓖麻油)分别作为液滴相和外相,可分析扁平和长椭球两种形状构型。施加的均匀电场强度E₀范围为0.125至1.75 kV/cm,覆盖了漏电介质模型(LDM)适用的小变形极限。同时也研究了无解析速度场可用的大变形液滴。我们的测量结果与小变形情况下的LDM理论吻合良好。流动由界面处的电场应力跃变引发,进而在液滴内部形成四个反向旋转的涡旋。在稳态下,解析解能充分预测液滴本体和界面处的径向及切向速度分量。然而,大变形时观察到细微差异,LDM理论低估了内部环流。此外,由于变形增大,界面处的速度呈现非均匀方位角分布。该速度分量的瞬态测量揭示了液滴EHD流动的动态响应。根据现有解析解,动态响应由其变形时间尺度主导。我们提出临界电毛细数约为0.1,低于该值时LDM可充分描述准稳态和瞬态的速度场。

英文摘要:

We present for the first time an experimental investigation of electrohydrodynamic (EHD) flows within a neutrally buoyant drop with initial radius of 2.25 mm. Utilizing particle image velocimetry (PIV) and high-speed shadowgraphy, we measure the internal circulation and reported velocity profiles in the bulk and at the interface of the drop. Two leaky dielectric liquids, Silicone and Castor oils, are employed as the drop and external phase, allowing for the analysis of two shape configurations: oblate and prolate. The strength of the applied uniform electric field, $E_o$, spans from 0.125 to 1.75 kV/cm, enabling the analysis covering the small-deformation limit, where the leaky dielectric model (LDM) is applicable. Drops with larger deformations, for which no analytical velocity field is available, are also investigated. Our measurements show a good agreement with the LDM theory for the small-deformation cases. The flows begin at the interface as a result of jump in the electric stresses, leading then to four counter-rotating vortices inside the drop. At permanent regime, the analytical solutions adequately predicts the radial and tangential velocity components both in the bulk and at the interface of the drop. However, a nuanced behavior is noticed for larger deformations, where the LDM theory underpredicts the internal circulation. Moreover, due to the increased deformation, a non-uniform azimuthal profile is observed for the velocity at the interface. Transient measurements of this velocity component enlighten the dynamic response of the EHD flows of the drop. Following the currently available analytical solutions, the dynamic response is governed by the time-scale of its deformation. We propose a critical value of electric capillary number of roughly 0.1 below which the LDM adequately describes the velocity field in both quasi steady-state and transitory regimes.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑