arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2401.02892physics.med-ph
收藏

黄金角的有理逼近:用于径向MRI的加速重建

Rational Approximation of Golden Angles: Accelerated Reconstructions for Radial MRI

Graz University of Technology(格拉茨工业大学);NYU School of Medicine(纽约大学医学院);German Centre for Cardiovascular Research (DZHK), Partner Site Lower Saxony(德国心血管研究卓越中心(DZHK),下萨克森州合作站点);The University of British Columbia(不列颠哥伦比亚大学);Vilcek Institute of Graduate Biomedical Sciences(维尔贝克生物医学研究生学院);BioTechMed-Graz(BioTechMed格拉茨)

Nick Scholand, Philip Schaten, Christina Graf, Daniel Mackner, H. Christian M. Holme, Moritz Blumenthal, Andrew Mao, Jakob Assländer, Martin Uecker

AI总结:

针对黄金比例径向MRI采样的无理增量问题,提出黄金角有理逼近(RAGA)采样方案,通过推导理论性质、对比旁瓣峰比并验证可行性,实现与黄金比例采样相近的PSF和SPR,简化数据处理且保留原优势。

摘要:

目的:开发一种通用径向采样方案,结合黄金比例采样的优势与等距角度模式的简洁性。基于黄金比例的采样方案中连续辐条间的无理角度,能灵活地回顾性选择时间分辨率,同时为每个独立分箱保留良好的k空间覆盖。然而,无理增量阻碍点扩散函数(PSF)的预计算,可能导致数值问题,并需要更复杂的处理步骤。为避免这些问题,开发了一种基于黄金角有理逼近(RAGA)的新采样方案。方法:通过数学推导得出RAGA采样的理论性质,数值计算旁瓣峰比(SPR)并与对应黄金比例采样方案比较。该采样方案在BART工具箱和径向梯度回波序列中实现,在体模定量成像和健康志愿者心脏扫描中验证可行性。结果:RAGA采样可准确逼近黄金比例采样,具有几乎相同的PSF和SPR;与黄金比例采样不同,每个帧可使用不同采样掩码以相同等距轨迹重建,且每个采集辐条的角度可编码为小索引,简化采集数据的处理。结论:RAGA采样保留黄金比例采样的优势,同时简化数据处理,使其成为动态和定量MRI的宝贵工具。

英文摘要:

Purpose: To develop a generic radial sampling scheme that combines the advantages of golden ratio sampling with simplicity of equidistant angular patterns. The irrational angle between consecutive spokes in golden ratio based sampling schemes enables a flexible retrospective choice of temporal resolution, while preserving good coverage of k-space for each individual bin. Nevertheless, irrational increments prohibit precomputation of the point-spread function (PSF), can lead to numerical problems, and require more complex processing steps. To avoid these problems, a new sampling scheme based on a rational approximation of golden angles (RAGA) is developed. Methods: The theoretical properties of RAGA sampling are mathematically derived. Sidelobe-to-peak ratios (SPR) are numerically computed and compared to the corresponding golden ratio sampling schemes. The sampling scheme is implemented in the BART toolbox and in a radial gradient-echo sequence. Feasibility is shown for quantitative imaging in a phantom and a cardiac scan of a healthy volunteer. Results: RAGA sampling can accurately approximate golden ratio sampling and has almost identical PSF and SPR. In contrast to golden ratio sampling, each frame can be reconstructed with the same equidistant trajectory using different sampling masks, and the angle of each acquired spoke can be encoded as a small index, which simplifies processing of the acquired data. Conclusion: RAGA sampling provides the advantages of golden ratio sampling while simplifying data processing, rendering it a valuable tool for dynamic and quantitative MRI.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑