Acquiring fully-sampled MRI $k$-space data is time-consuming, and collecting accelerated data can reduce the acquisition time. Employing 2D Cartesian-rectilinear subsampling schemes is a conventional approach for accelerated acquisitions; however, this often results in imprecise reconstructions, even with the use of Deep Learning (DL), especially at high acceleration factors. Non-rectilinear or non-Cartesian trajectories can be implemented in MRI scanners as alternative subsampling options. This work investigates the impact of the $k$-space subsampling scheme on the quality of reconstructed accelerated MRI measurements produced by trained DL models. The Recurrent Variational Network (RecurrentVarNet) was used as the DL-based MRI-reconstruction architecture. Cartesian, fully-sampled multi-coil $k$-space measurements from three datasets were retrospectively subsampled with different accelerations using eight distinct subsampling schemes: four Cartesian-rectilinear, two Cartesian non-rectilinear, and two non-Cartesian. Experiments were conducted in two frameworks: scheme-specific, where a distinct model was trained and evaluated for each dataset-subsampling scheme pair, and multi-scheme, where for each dataset a single model was trained on data randomly subsampled by any of the eight schemes and evaluated on data subsampled by all schemes. In both frameworks, RecurrentVarNets trained and evaluated on non-rectilinearly subsampled data demonstrated superior performance, particularly for high accelerations. In the multi-scheme setting, reconstruction performance on rectilinearly subsampled data improved when compared to the scheme-specific experiments. Our findings demonstrate the potential for using DL-based methods, trained on non-rectilinearly subsampled measurements, to optimize scan time and image quality.
Netherlands Cancer Institute(荷兰癌症研究所);University of Amsterdam(阿姆斯特丹大学)
In spite of its extensive adaptation in almost every medical diagnostic and examinatorial application, Magnetic Resonance Imaging (MRI) is still a slow imaging modality which limits its use for dynamic imaging. In recent years, Parallel Imaging (PI) and Compressed Sensing (CS) have been utilised to accelerate the MRI acquisition. In clinical settings, subsampling the k-space measurements during scanning time using Cartesian trajectories, such as rectilinear sampling, is currently the most conventional CS approach applied which, however, is prone to producing aliased reconstructions. With the a…
University College London(伦敦大学学院);Zhejiang Lab(之江实验室);Vall d’Hebron Barcelona Hospital(巴塞罗那瓦尔德希伯伦医院)
We present PROSUB: PROgressive SUBsampling, a deep learning based, automated methodology that subsamples an oversampled data set (e.g. multi-channeled 3D images) with minimal loss of information. We build upon a recent dual-network approach that won the MICCAI MUlti-DIffusion (MUDI) quantitative MRI measurement sampling-reconstruction challenge, but suffers from deep learning training instability, by subsampling with a hard decision boundary. PROSUB uses the paradigm of recursive feature elimination (RFE) and progressively subsamples measurements during deep learning training, improving optimi…
EPFL(洛桑联邦理工学院);Bilkent University(比尔肯特大学);National University of Singapore(新加坡国立大学)
In the area of magnetic resonance imaging (MRI), an extensive range of non-linear reconstruction algorithms have been proposed that can be used with general Fourier subsampling patterns. However, the design of these subsampling patterns has typically been considered in isolation from the reconstruction rule and the anatomy under consideration. In this paper, we propose a learning-based framework for optimizing MRI subsampling patterns for a specific reconstruction rule and anatomy, considering both the noiseless and noisy settings. Our learning algorithm has access to a representative set of t…
In today's clinical practice, magnetic resonance imaging (MRI) is routinely accelerated through subsampling of the associated Fourier domain. Currently, the construction of these subsampling strategies - known as experimental design - relies primarily on heuristics. We propose to learn experimental design strategies for accelerated MRI with policy gradient methods. Unexpectedly, our experiments show that a simple greedy approximation of the objective leads to solutions nearly on-par with the more general non-greedy approach. We offer a partial explanation for this phenomenon rooted in greater …
Memorial Sloan Kettering Cancer Center(纪念斯隆凯特琳癌症中心);Graz University of Technology(格拉茨工业大学);GE Healthcare(GE医疗)
Purpose: To investigate feasibility of accelerating prostate diffusion-weighted imaging (DWI) by reducing the number of acquired averages and denoising the resulting image using a proposed guided denoising convolutional neural network (DnCNN). Materials and Methods: Raw data from the prostate DWI scans were retrospectively gathered (between July 2018 and July 2019) from six single-vendor MRI scanners. 118 data sets were used for training and validation (age: 64.3 +- 8 years) and 37 - for testing (age: 65.1 +- 7.3 years). High b-value diffusion-weighted (hb-DW) data were reconstructed into nois…
University of Bath(巴斯大学);Technical University of Munich(慕尼黑工业大学);GE Healthcare(通用电气医疗集团);Technische Hochschule Ingolstadt(英戈尔施塔特应用技术大学)
Current spatiotemporal deep learning approaches to Magnetic Resonance Fingerprinting (MRF) build artefact-removal models customised to a particular k-space subsampling pattern which is used for fast (compressed) acquisition. This may not be useful when the acquisition process is unknown during training of the deep learning model and/or changes during testing time. This paper proposes an iterative deep learning plug-and-play reconstruction approach to MRF which is adaptive to the forward acquisition process. Spatiotemporal image priors are learned by an image denoiser i.e. a Convolutional Neura…
University of Texas at Austin(德克萨斯大学奥斯汀分校);California Institute of Technology(加州理工学院);Harvard Medical School(哈佛医学院);Massachusetts Institute of Technology(麻省理工学院)
Accelerated MRI shortens acquisition time by subsampling in the measurement $κ$-space. Recovering a high-fidelity anatomical image from subsampled measurements requires close cooperation between two components: (1) a sampler that chooses the subsampling pattern and (2) a reconstructor that recovers images from incomplete measurements. In this paper, we leverage the sequential nature of MRI measurements, and propose a fully differentiable framework that jointly learns a sequential sampling policy simultaneously with a reconstruction strategy. This co-designed framework is able to adapt during a…
Learning Task-Specific Strategies for Accelerated MRI
California Institute of Technology(加州理工学院);Massachusetts Institute of Technology(麻省理工学院);Athinoula A. Martinos Center for Biomedical Imaging(阿西努拉·A.马蒂诺斯生物医学成像中心);MGH(麻省总医院);Harvard Medical School(哈佛医学院)
Organ motion poses an unresolved challenge in image-guided interventions. In the pursuit of solving this problem, the research field of time-resolved volumetric magnetic resonance imaging (4D MRI) has evolved. However, current techniques are unsuitable for most interventional settings because they lack sufficient temporal and/or spatial resolution or have long acquisition times. In this work, we propose a novel approach for real-time, high-resolution 4D MRI with large fields of view for MR-guided interventions. To this end, we trained a convolutional neural network (CNN) end-to-end to predict …
Change Healthcare, Enterprise Imaging Solutions(Change Healthcare 企业影像解决方案);Mecklenburg Radiology Associates(梅克伦堡放射学联合诊所);University of British Columbia(不列颠哥伦比亚大学)
Standardized body region labelling of individual images provides data that can improve human and computer use of medical images. A CNN-based classifier was developed to identify body regions in CT and MRI. 17 CT (18 MRI) body regions covering the entire human body were defined for the classification task. Three retrospective databases were built for the AI model training, validation, and testing, with a balanced distribution of studies per body region. The test databases originated from a different healthcare network. Accuracy, recall and precision of the classifier was evaluated for patient a…
KTH Royal Institute of Technology(KTH皇家理工学院);Science for Life Laboratory(生命科学实验室)
Artifacts on magnetic resonance scans are a serious challenge for both radiologists and computer-aided diagnosis systems. Most commonly, artifacts are caused by motion of the patients, but can also arise from device-specific abnormalities such as noise patterns. Irrespective of the source, artifacts can not only render a scan useless, but can potentially induce misdiagnoses if left unnoticed. For instance, an artifact may masquerade as a tumor or other abnormality. Retrospective artifact correction (RAC) is concerned with removing artifacts after the scan has already been taken. In this work, …
Compressed sensing applied to magnetic resonance imaging (MRI) allows to reduce the scanning time by enabling images to be reconstructed from highly undersampled data. In this paper, we tackle the problem of designing a sampling mask for an arbitrary reconstruction method and a limited acquisition budget. Namely, we look for an optimal probability distribution from which a mask with a fixed cardinality is drawn. We demonstrate that this problem admits a compactly supported solution, which leads to a deterministic optimal sampling mask. We then propose a stochastic greedy algorithm that (i) pro…
Retrospective artifact correction (RAC) improves image quality post acquisition and enhances image usability. Recent machine learning driven techniques for RAC are predominantly based on supervised learning and therefore practical utility can be limited as data with paired artifact-free and artifact-corrupted images are typically insufficient or even non-existent. Here we show that unwanted image artifacts can be disentangled and removed from an image via an RAC neural network learned with unpaired data. This implies that our method does not require matching artifact-corrupted data to be eithe…
Phase-contrast magnetic resonance imaging (MRI) provides time-resolved quantification of blood flow dynamics that can aid clinical diagnosis. Long in vivo scan times due to repeated three-dimensional (3D) volume sampling over cardiac phases and breathing cycles necessitate accelerated imaging techniques that leverage data correlations. Standard compressed sensing reconstruction methods require tuning of hyperparameters and are computationally expensive, which diminishes the potential reduction of examination times. We propose an efficient model-based deep neural reconstruction network and eval…
United Imaging Intelligence(联影智能);UIH America, Inc.(联影美国公司);United Imaging Healthcare(联影医疗)
Retrospectively gated cine (retro-cine) MRI is the clinical standard for cardiac functional analysis. Deep learning (DL) based methods have been proposed for the reconstruction of highly undersampled MRI data and show superior image quality and magnitude faster reconstruction time than CS-based methods. Nevertheless, it remains unclear whether DL reconstruction is suitable for cardiac function analysis. To address this question, in this study we evaluate and compare the cardiac functional values (EDV, ESV and EF for LV and RV, respectively) obtained from highly accelerated MRI acquisition usin…
Dynamic Magnetic Resonance Imaging (MRI) is known to be a powerful and reliable technique for the dynamic imaging of internal organs and tissues, making it a leading diagnostic tool. A major difficulty in using MRI in this setting is the relatively long acquisition time (and, hence, increased cost) required for imaging in high spatio-temporal resolution, leading to the appearance of related motion artifacts and decrease in resolution. Compressed Sensing (CS) techniques have become a common tool to reduce MRI acquisition time by subsampling images in the k-space according to some acquisition tr…
Yonsei University(延世大学);GE Healthcare(通用电气医疗);Seoul National University Hospital(首尔大学医院)
In this paper, we develop an efficient retrospective deep learning method called stacked U-Nets with self-assisted priors to address the problem of rigid motion artifacts in MRI. The proposed work exploits the usage of additional knowledge priors from the corrupted images themselves without the need for additional contrast data. The proposed network learns missed structural details through sharing auxiliary information from the contiguous slices of the same distorted subject. We further design a refinement stacked U-Nets that facilitates preserving of the image spatial details and hence improv…
Rensselaer Polytechnic Institute(伦斯勒理工学院);Wake Forest School of Medicine(维克森林大学医学院)
Treatment decisions for brain metastatic disease rely on knowledge of the primary organ site, and currently made with biopsy and histology. Here we develop a novel deep learning approach for accurate non-invasive digital histology with whole-brain MRI data. Our IRB-approved single-site retrospective study was comprised of patients (n=1,399) referred for MRI treatment-planning and gamma knife radiosurgery over 21 years. Contrast-enhanced T1-weighted and T2-weighted Fluid-Attenuated Inversion Recovery brain MRI exams (n=1,582) were preprocessed and input to the proposed deep learning workflow fo…
Spatiotemporal implicit neural representation for unsupervised dynamic MRI reconstruction
School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China(上海交通大学生物医学工程学院);School of Information Science and Technology, ShanghaiTech University, Shanghai, China(上海科技大学信息科学与技术学院);iHuman Institute, Shanghaitech University, Shanghai, China(上海科技大学iHuman研究所)
MRAnnotator: multi-Anatomy and many-Sequence MRI segmentation of 44 structures
BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai(西奈山伊坎医学院生物医学工程与影像研究所);Department of Diagnostic, Molecular, and Interventional Radiology, Icahn School of Medicine at Mount Sinai(西奈山伊坎医学院诊断、分子与介入放射学系);Rotterdam School of Management, Erasmus University Rotterdam(伊拉斯姆斯大学鹿特丹管理学院);East River Medical Imaging(东河医学影像中心);Department of Radiology, Cornell Medicine(康奈尔医学院放射学系);Windreich Department of Artificial Intelligence and Human Health, Icahn School of Medicine at Mount Sinai(西奈山伊坎医学院温赖克人工智能与人类健康系)
University of Bath(巴斯大学);GE Healthcare(通用电气医疗集团);Technical University of Munich(慕尼黑工业大学);Technische Hochschule Ingolstadt(英戈尔施塔特应用技术大学)
Current state-of-the-art reconstruction for quantitative tissue maps from fast, compressive, Magnetic Resonance Fingerprinting (MRF), use supervised deep learning, with the drawback of requiring high-fidelity ground truth tissue map training data which is limited. This paper proposes NonLinear Equivariant Imaging (NLEI), a self-supervised learning approach to eliminate the need for ground truth for deep MRF image reconstruction. NLEI extends the recent Equivariant Imaging framework to nonlinear inverse problems such as MRF. Only fast, compressed-sampled MRF scans are used for training. NLEI le…
Technische Universität München(慕尼黑工业大学);University of Edinburgh(爱丁堡大学);University of Sheffield(谢菲尔德大学)
Dynamic contrast-enhanced (DCE) MRI is an evolving imaging technique that provides a quantitative measure of pharmacokinetic (PK) parameters in body tissues, in which series of T1-weighted images are collected following the administration of a paramagnetic contrast agent. Unfortunately, in many applications, conventional clinical DCE-MRI suffers from low spatiotemporal resolution and insufficient volume coverage. In this paper, we propose a novel deep learning based approach to directly estimate the PK parameters from undersampled DCE-MRI data. Specifically, we design a custom loss function wh…
MotionTTT: 2D Test-Time-Training Motion Estimation for 3D Motion Corrected MRI
School of Computation, Information and Technology, Technical University of Munich(慕尼黑工业大学计算、信息与技术学院);School of Medicine and Health, Technical University of Munich(慕尼黑工业大学医学与健康学院)
Department of Radiology, Massachusetts General Hospital(麻省总医院放射科);Radiology, Perelman School of Medicine, University of Pennsylvania(宾夕法尼亚大学佩雷尔曼医学院放射科)
In fetal-brain MRI, head-pose changes between prescription and acquisition present a challenge to obtaining the standard sagittal, coronal and axial views essential to clinical assessment. As motion limits acquisitions to thick slices that preclude retrospective resampling, technologists repeat ~55-second stack-of-slices scans (HASTE) with incrementally reoriented field of view numerous times, deducing the head pose from previous stacks. To address this inefficient workflow, we propose a robust head-pose detection algorithm using full-uterus scout scans (EPI) which take ~5 seconds to acquire. …
Shanghai Jiao Tong University(上海交通大学);University of Illinois Urbana-Champaign(伊利诺伊大学厄巴纳-香槟分校);Ruijin Hospital affiliated to Shanghai Jiao Tong University School of Medicine(上海交通大学医学院附属瑞金医院);KTH Royal Institute of Technology(瑞典皇家理工学院);Mayo Clinic in Arizona(亚利桑那州妙佑医疗国际);ShanghaiTech University(上海科技大学)
Interventional magnetic resonance imaging (i-MRI) for surgical guidance could help visualize the interventional process such as deep brain stimulation (DBS), improving the surgery performance and patient outcome. Different from retrospective reconstruction in conventional dynamic imaging, i-MRI for DBS has to acquire and reconstruct the interventional images sequentially online. Here we proposed a convolutional long short-term memory (Conv-LSTM) based recurrent neural network (RNN), or ConvLR, to reconstruct interventional images with golden-angle radial sampling. By using an initializer and C…
University College London(伦敦大学学院);Technion -- Israel Institute of Technology(以色列理工学院);Heriot-Watt University(赫瑞-瓦特大学)
Medical imaging tasks often involve multiple contrasts, such as T1- and T2-weighted magnetic resonance imaging (MRI) data. These contrasts capture information associated with the same underlying anatomy and thus exhibit similarities. In this paper, we propose a Coupled Dictionary Learning based multi-contrast MRI reconstruction (CDLMRI) approach to leverage an available guidance contrast to restore the target contrast. Our approach consists of three stages: coupled dictionary learning, coupled sparse denoising, and $k$-space consistency enforcing. The first stage learns a group of dictionaries…
École polytechnique fédérale de Lausanne (EPFL)(洛桑联邦理工学院);University Hospital (CHUV)(沃州大学医院);University of Lausanne (UNIL)(洛桑大学);Center for Biomedical Imaging (CIBM)(生物医学成像中心)
We propose a novel unsupervised deep-learning-based algorithm for dynamic magnetic resonance imaging (MRI) reconstruction. Dynamic MRI requires rapid data acquisition for the study of moving organs such as the heart. Existing reconstruction methods suffer from restrictions either in the model design or in the absence of ground-truth data, resulting in low image quality. We introduce a generalized version of the deep-image-prior approach, which optimizes the network weights to fit a sequence of sparsely acquired dynamic MRI measurements. Our method needs neither prior training nor additional da…
MIT(麻省理工学院);Boston Children’s Hospital(波士顿儿童医院);Harvard Medical School(哈佛医学院)
Fetal MRI is heavily constrained by unpredictable and substantial fetal motion that causes image artifacts and limits the set of viable diagnostic image contrasts. Current mitigation of motion artifacts is predominantly performed by fast, single-shot MRI and retrospective motion correction. Estimation of fetal pose in real time during MRI stands to benefit prospective methods to detect and mitigate fetal motion artifacts where inferred fetal motion is combined with online slice prescription with low-latency decision making. Current developments of deep reinforcement learning (DRL), offer a nov…
Artificial Intelligence (Deep Learning(DL)/ Machine Learning(ML)) techniques are widely being used to address and overcome all kinds of ill-posed problems in medical imaging which was or in fact is seemingly impossible. Reducing gradient directions but harnessing high angular resolution(HAR) diffusion data in MR that retains clinical features is an important and challenging problem in the field. While the DL/ML approaches are promising, it is important to incorporate relevant context for the data to ensure that maximum prior information is provided for the AI model to infer the posterior. In t…
Cornell University(康奈尔大学);Weill Medical College of Cornell University(康奈尔大学威尔医学院)
The previously established LOUPE (Learning-based Optimization of the Under-sampling Pattern) framework for optimizing the k-space sampling pattern in MRI was extended in three folds: firstly, fully sampled multi-coil k-space data from the scanner, rather than simulated k-space data from magnitude MR images in LOUPE, was retrospectively under-sampled to optimize the under-sampling pattern of in-vivo k-space data; secondly, binary stochastic k-space sampling, rather than approximate stochastic k-space sampling of LOUPE during training, was applied together with a straight-through (ST) estimator …
Manual prescription of the field of view (FOV) by MRI technologists is variable and prolongs the scanning process. Often, the FOV is too large or crops critical anatomy. We propose a deep-learning framework, trained by radiologists' supervision, for automating FOV prescription. An intra-stack shared feature extraction network and an attention network are used to process a stack of 2D image inputs to generate output scalars defining the location of a rectangular region of interest (ROI). The attention mechanism is used to make the model focus on the small number of informative slices in a stack…
A novel neural network architecture, known as DL-ESPIRiT, is proposed to reconstruct rapidly acquired cardiac MRI data without field-of-view limitations which are present in previously proposed deep learning-based reconstruction frameworks. Additionally, a novel convolutional neural network based on separable 3D convolutions is integrated into DL-ESPIRiT to more efficiently learn spatiotemporal priors for dynamic image reconstruction. The network is trained on fully-sampled 2D cardiac cine datasets collected from eleven healthy volunteers with IRB approval. DL-ESPIRiT is compared against a sta…
We propose and evaluate a new MRI reconstruction method named LORAKI that trains an autocalibrated scan-specific recurrent neural network (RNN) to recover missing k-space data. Methods like GRAPPA, SPIRiT, and AC-LORAKS assume that k-space data has shift-invariant autoregressive structure, and that the scan-specific autoregression relationships needed to recover missing samples can be learned from fully-sampled autocalibration (ACS) data. Recently, the structure of the linear GRAPPA method has been translated into a nonlinear deep learning method named RAKI. RAKI uses ACS data to train an arti…
TotalSegmentator MRI: Robust Sequence-independent Segmentation of Multiple Anatomic Structures in MRI
University Hospital Basel(巴塞尔大学医院);University of Freiburg(弗莱堡大学);University Hospital of Tuebingen(蒂宾根大学医院);German Cancer Research Center(德国癌症研究中心);Karlsruhe Institute of Technology(卡尔斯鲁厄理工学院)
Korea Advanced Institute of Science & Technology (KAIST)(韩国科学技术院)
Purpose: Compressed sensing MRI (CS-MRI) from single and parallel coils is one of the powerful ways to reduce the scan time of MR imaging with performance guarantee. However, the computational costs are usually expensive. This paper aims to propose a computationally fast and accurate deep learning algorithm for the reconstruction of MR images from highly down-sampled k-space data. Theory: Based on the topological analysis, we show that the data manifold of the aliasing artifact is easier to learn from a uniform subsampling pattern with additional low-frequency k-space data. Thus, we develop de…
DCRA-Net: Attention-Enabled Reconstruction Model for Dynamic Fetal Cardiac MRI
King’s College London(伦敦国王学院);Evelina London Children’s Hospital(伊芙琳娜伦敦儿童医院);Imperial College London(帝国理工学院);Klinikum rechts der Isar, Technical University of Munich(慕尼黑工业大学右岸医院)
Evaluation of Machine Learning Reconstruction Techniques for Accelerated Brain MRI Scans
Humber River Hospital(亨伯河医院);Toronto Western Hospital, University of Toronto(多伦多大学多伦多西区医院);Foqus Technologies Inc.(Foqus 技术公司);Robarts Research Institute, Western University(西安大略大学罗巴茨研究所)
University Hospital Tübingen(蒂宾根大学医院);University of Stuttgart(斯图加特大学);Max-Planck Institute for Intelligent Systems(马克斯·普朗克智能系统研究所);Eberhard Karls University(埃伯哈德·卡尔斯大学);Helmholtz Zentrum München(慕尼黑亥姆霍兹中心);German Center for Diabetes Research(德国糖尿病研究中心);University of Freiburg(弗赖堡大学)
Purpose: To enable fast and reliable assessment of subcutaneous and visceral adipose tissue compartments derived from whole-body MRI. Methods: Quantification and localization of different adipose tissue compartments from whole-body MR images is of high interest to examine metabolic conditions. For correct identification and phenotyping of individuals at increased risk for metabolic diseases, a reliable automatic segmentation of adipose tissue into subcutaneous and visceral adipose tissue is required. In this work we propose a 3D convolutional neural network (DCNet) to provide a robust and obje…
Oslo University Hospital(奥斯陆大学医院);Stanford University(斯坦福大学)
The purpose was to assess the clinical value of a novel DropOut model for detecting and segmenting brain metastases, in which a neural network is trained on four distinct MRI sequences using an input dropout layer, thus simulating the scenario of missing MRI data by training on the full set and all possible subsets of the input data. This retrospective, multi-center study, evaluated 165 patients with brain metastases. A deep learning based segmentation model for automatic segmentation of brain metastases, named DropOut, was trained on multi-sequence MRI from 100 patients, and validated/tested …
Weakly Convex Ridge Regularization for 3D Non-Cartesian MRI Reconstruction
Faculty of Mathematics, Chemnitz University of Technology(开姆尼茨工业大学数学学院);NeuroSpin, Frédéric Joliot Institute for Life Sciences, CEA Paris-Saclay(法国原子能委员会巴黎-萨克雷大学弗雷德里克·约里奥生命科学研究所神经自旋中心);MIND, Inria Saclay Centre(法国国家信息与自动化研究所萨克雷中心MIND团队);Siemens Healthineers(西门子医疗)
A cross-modal generative model for incomplete and degraded prostate MRI with multicentre clinical validation
College of Computing and Data Science, Nanyang Technological University(南洋理工大学计算与数据科学学院);School of Computer Science and Technology, Tongji University(同济大学计算机科学与技术学院);Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine(上海交通大学医学院附属仁济医院);National University of Singapore(新加坡国立大学);Shanghai East Hospital, Tongji University School of Medicine(同济大学医学院附属东方医院);McWilliams School of Biomedical Informatics, The University of Texas Health Science Center at Houston (UTHealth Houston)(德克萨斯大学休斯顿健康科学中心麦克威廉姆斯生物信息学院);School of Transportation, Southeast University(东南大学交通学院);Ningbo Hangzhou Bay Hospital(宁波杭州湾医院);Changhai Hospital, Naval Medical University(海军军医大学长海医院)