arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2503.18162physics.med-phcs.AIcs.CVeess.IV

SNRAware:通过SNR单位训练和G因子图增强改进深度学习MRI去噪

SNRAware: Improved Deep Learning MRI Denoising with SNR Unit Training and G-factor Map Augmentation

Microsoft Research(微软研究院);National Institutes of Health(美国国立卫生研究院);University College London(伦敦大学学院);Barts Health NHS Trust(巴特保健国民保健信托基金)
Hui Xue, Sarah M. Hooper, Iain Pierce, Rhodri H. Davies, John Stairs, Joseph Naegele, Adrienne E. Campbell-Washburn, Charlotte Manisty, James C. Moon, Thomas A.… 展开作者

Hui Xue, Sarah M. Hooper, Iain Pierce, Rhodri H. Davies, John Stairs, Joseph Naegele, Adrienne E. Campbell-Washburn, Charlotte Manisty, James C. Moon, Thomas A. Treibel, Peter Kellman, Michael S. Hansen

AI总结:

本研究提出SNRAware训练方案,利用MRI重建噪声分布信息结合合成数据增强训练深度学习模型,在3T心脏数据训练后,于1.5T多部位多序列MRI中实现优异去噪泛化性能。

摘要:

本研究旨在开发并评估一种新型深度学习磁共振(MR)去噪方法,该方法利用重建过程中的定量噪声分布信息,提升去噪性能与泛化能力。\n 这项回顾性研究采用两种骨干架构,在包含96605个3T场强下采集的心脏门控电影复合序列、共计2885236张图像的大型数据集上,训练了14种不同的Transformer和卷积模型。所提出的训练方案名为SNRAware,它利用MRI重建过程的相关知识,通过模拟大规模、高质量且多样化的合成数据集,并向模型提供噪声分布的定量信息,来提升去噪性能。研究在包含3000个样本的留出数据集上进行分布内测试,采用峰值信噪比(PSNR)和结构相似性指数(SSIM)衡量性能,并与未使用噪声增强的消融实验进行对比。同时,研究在1.5T场强下采集的心脏实时电影成像、首过心脏灌注成像以及神经和脊柱MRI数据上进行分布外测试,以验证模型在不同成像序列、动态变化对比度、不同解剖部位和场强下的泛化能力。分布内测试中表现最优的模型在分布外样本上也展现出良好的泛化性,分别使实时电影成像和灌注成像的对比噪声比(CNR)提升6.5倍和2.9倍。此外,使用100%心脏电影数据训练的模型,在T1 MPRAGE神经3D扫描和T2 TSE脊柱MRI上也具备良好的泛化表现。

英文摘要:

To develop and evaluate a new deep learning MR denoising method that leverages quantitative noise distribution information from the reconstruction process to improve denoising performance and generalization. This retrospective study trained 14 different transformer and convolutional models with two backbone architectures on a large dataset of 2,885,236 images from 96,605 cardiac retro-gated cine complex series acquired at 3T. The proposed training scheme, termed SNRAware, leverages knowledge of the MRI reconstruction process to improve denoising performance by simulating large, high quality, and diverse synthetic datasets, and providing quantitative information about the noise distribution to the model. In-distribution testing was performed on a hold-out dataset of 3000 samples with performance measured using PSNR and SSIM, with ablation comparison without the noise augmentation. Out-of-distribution tests were conducted on cardiac real-time cine, first-pass cardiac perfusion, and neuro and spine MRI, all acquired at 1.5T, to test model generalization across imaging sequences, dynamically changing contrast, different anatomies, and field strengths. The best model found in the in-distribution test generalized well to out-of-distribution samples, delivering 6.5x and 2.9x CNR improvement for real-time cine and perfusion imaging, respectively. Further, a model trained with 100% cardiac cine data generalized well to a T1 MPRAGE neuro 3D scan and T2 TSE spine MRI.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑