Evaluating the Performance of Ultra-Low-Field MRI for In-vivo 3D Current Density Imaging of the Human Head
Peter Hömmen, Antti J. Mäkinen, Alexander Hunold, René Machts, Jens Haueisen, Koos C. J. Zevenhoven, Risto J. Ilmoniemi, Rainer Körber
备注:
18 pages, 8 figures. This project has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 686865
Magnetic fields associated with currents flowing in tissue can be measured non-invasively by means of zero-field-encoded ultra-low-field magnetic resonance imaging (ULF MRI) enabling current density imaging (CDI) and possibly conductivity mapping of human head tissues. Since currents applied to a human are limited by safety regulations and only a small fraction of the current passes through the relatively high-resistive skull, a sufficient signal-to-noise ratio (SNR) may be difficult to obtain when using this method. In this work, we study the relationship between the image SNR and the SNR of the field reconstructions from zero-field-encoded data. We evaluate these results for two existing ULF MRI scanners, one ultra-sensitive single-channel system and one whole-head multi-channel system, by simulating sequences necessary for current-density reconstruction. We also derive realistic current-density and magnetic-field estimates from finite-element-method simulations based on a three-compartment head model. We found that existing ULF-MRI systems reach sufficient SNR to detect intra-cranial current distributions with statistical uncertainty below 10%. However, they also reveal that image artifacts influence the reconstruction quality. Further, our simulations indicate that current-density reconstruction in the scalp requires a resolution less than 5 mm and demonstrate that the necessary sensitivity coverage can be accomplished by multi-channel devices.
Although nanodiamonds have long being considered as a potential tool for biomedical research, the practical in vivo application of nanodiamonds remains relatively unexplored. In this paper, we present the first application of in vivo MRI contrast enhancement using only iron embedded magnetic nanodiamonds. MR image enhancement was clearly demonstrated in the rendering of T2-weighted images of mice obtained using an unmodified commercial MRI scanner. The excellent contrast obtained using these nanodiamonds opens the door to the non-invasive in vivo tracking of NDs and image enhancement. In the f…
Purpose: To develop an accelerated, robust, and accurate diffusion MRI acquisition and reconstruction technique for submillimeter whole human brain in-vivo scan on a clinical scanner. Methods: We extend the ultra-high resolution diffusion MRI acquisition technique, gSlider, by allowing under-sampling in q-space and Radio-Frequency (RF)-encoded data, thereby accelerating the total acquisition time of conventional gSlider. The novel method, termed gSlider-SR, compensates for the lack of acquired information by exploiting redundancy in the dMRI data using a basis of Spherical Ridgelets (SR), whil…
SQUID-based MRI (magnetic resonance imaging) at microtesla fields has developed significantly over the past few years. Here we describe application of this method for magnetic relaxation measurements in the living human brain. We report values of the longitudinal relaxation time T1 for brain tissues, measured in vivo for the first time at microtesla fields. The experiments were performed at 46 microtesla field using a seven-channel SQUID system designed for microtesla MRI and MEG. Values of T1, measured for different tissues at this field, are found to be close (within 5%) to the corresponding…
Purpose: To design a low-cost, portable permanent magnet-based MRI system capable of obtaining in vivo MR images within a reasonable scan time. Methods: A discretized Halbach permanent magnet array with a clear bore diameter of 27 cm was designed for operation at 50 mT. Custom built gradient coils, radiofrequency coil, gradient amplifiers and radiofrequency amplifier were integrated and tested on both phantoms and in vivo. Results: Phantom results showed that the gradient non-linearity in the y- and z-directions was less than 5% over a 15 cm field-of-view and did not need correcting. For the x…
University College London(伦敦大学学院);Basque Center on Cognition, Brain and Language(巴斯克认知、大脑与语言中心);University of Castilla-La Mancha(卡斯蒂利亚-拉曼恰大学);Massachusetts General Hospital(麻省总医院);Harvard Medical School(哈佛医学院);Technical University of Denmark(丹麦技术大学)
The human thalamus is a brain structure that comprises numerous, highly specific nuclei. Since these nuclei are known to have different functions and to be connected to different areas of the cerebral cortex, it is of great interest for the neuroimaging community to study their volume, shape and connectivity in vivo with MRI. In this study, we present a probabilistic atlas of the thalamic nuclei built using ex vivo brain MRI scans and histological data, as well as the application of the atlas to in vivo MRI segmentation. The atlas was built using manual delineation of 26 thalamic nuclei on the…
We investigated whether a combination of k-space undersampling and variable density averaging enhances image quality for low-SNR MRI acquisitions. We implemented 3D Cartesian k-space prospective undersampling with a variable number of averages for each k-line. The performance of this compressed sensing with variable-density averaging (CS-VDA) method was evaluated in retrospective analysis of fully sampled phantom MRI measurements, as well as for prospectively accelerated in vivo 3D brain and knee MRI scans. Both phantom and in vivo results showed that acquisitions using the CS-VDA approach res…
Developments in metamaterials and related structures such as metasurfaces have opened up new possibilities in designing materials and devices with unique properties. The main progress related to electromagnetic waves applications was done in optical and microwave spectra. Here we report about a new hybrid metasurface structure, comprising a two-dimensional metamaterial surface and a very high permittivity dielectric substrate that was designed to enhance the performance of an ultra-high field MRI scanner. This new flexible and compact resonant structure is the first one which can be integrated…
In this work we introduce a new method that combines Parallel MRI and Compressed Sensing (CS) for accelerated image reconstruction from subsampled k-space data. The method first computes a convolved image, which gives the convolution between a user-defined kernel and the unknown MR image, and then reconstructs the image by CS-based image deblurring, in which CS is applied for removing the inherent blur stemming from the convolution process. This method is hence termed CORE-Deblur. Retrospective subsampling experiments with data from a numerical brain phantom and in-vivo 7T brain scans showed t…
A large number of mathematical models have been proposed to describe the measured signal in diffusion-weighted (DW) magnetic resonance imaging (MRI) and infer properties about the white matter microstructure. However, a head-to-head comparison of DW-MRI models is critically missing in the field. To address this deficiency, we organized the "White Matter Modeling Challenge" during the International Symposium on Biomedical Imaging (ISBI) 2015 conference. This competition aimed at identifying the DW-MRI models that best predict unseen DW data. in vivo DW-MRI data was acquired on the Connectom sca…
Considerations and recommendations from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 3 -- Ex vivo imaging: data processing, comparisons with microscopy, and tractography
In-vivo imaging with a low-cost MRI scanner and cloud data processing in low-resource settings
MRILab, Institute for Molecular Imaging and Instrumentation (i3M), Consejo Superior de Investigaciones Científicas (CSIC) & Universitat Politècnica de València (UPV)(分子成像与仪器研究所 (i3M),西班牙高等科学研究理事会 (CSIC) 与巴伦西亚理工大学 (UPV));Mbarara University of Science and Technology (MUST)(姆巴拉拉科技大学 (MUST));McGill University(麦吉尔大学);Leiden University Medical Center (LUMC)(莱顿大学医学中心 (LUMC));Microsoft Research, Health Futures(微软研究院,健康未来部门);Facultad de Ciencias Aplicadas, Universidad Comunera(应用科学学院,科穆内拉大学);Yale University(耶鲁大学)
Low-Cost and Detunable Wireless Resonator Glasses for Enhanced Eye MRI with Concurrent High-Quality Whole Brain MRI
Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center(范德堡大学成像科学研究所,范德堡大学医学中心);Department of Electrical and Computer Engineering, Vanderbilt University(范德堡大学电气与计算机工程系);Philips(飞利浦);Department of Biomedical Engineering, Vanderbilt University(范德堡大学生物医学工程系);Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center(范德堡大学医学中心放射学与放射科学系)
Inertial sensors are commonly used to measure human head motion. Some sensors have been validated with dummy or cadaver experiments, but methods to evaluate sensors in vivo are lacking. Here we present an in vivo method using high speed video to evaluate teeth-mounted (mouthguard), soft tissue-mounted (skin patch), and headgear-mounted (skull cap) sensors during 6-13g sagittal soccer head impacts. Sensor coupling to the skull is quantified by displacement from an ear-canal reference. Mouthguard displacements were within video measurement error (<1mm), while the skin patch and skull cap displac…
Considerations and recommendations from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 2 -- Ex vivo imaging: added value and acquisition
Unveiling neuronal microstructure in the human brain in vivo with time-dependent radial diffusivity in MRI
GE HealthCare(通用医疗);The University of Iowa(爱荷华大学);Uniformed Services University(联邦服务大学);Walter Reed National Military Medical Center(沃尔特·里德国家军事医疗中心);Mass General Brigham, Harvard Medical School(麻省总医院布里格姆医院,哈佛医学院);King's College London(伦敦国王学院);University of Wisconsin-Madison(威斯康星大学麦迪逊分校)
For high precision in source reconstruction of magnetoencephalography (MEG) or electroencephalography data, high accuracy of the coregistration of sources and sensors is mandatory. Usually, the source space is derived from magnetic resonance imaging (MRI). In most cases, however, no quality assessment is reported for sensor-to-MRI coregistrations. If any, typically root mean squares (RMS) of point residuals are provided. It has been shown, however, that RMS of residuals do not correlate with coregistration errors. We suggest using target registration error (TRE) as criterion for the quality of…
Purpose: The impact of microscopic diffusional kurtosis ($μK$) - arising from restricted diffusion and/or structural disorder - remains a controversial issue in contemporary diffusion MRI (dMRI). Recently, Correlation Tensor MRI (CTI) was introduced to disentangle the sources contributing to diffusional kurtosis, without relying on a-priori assumptions. Here, we aimed to investigate $μK$ in in vivo rat brains and assess its impact on state-of-the-art methods ignoring $μK$. Methods: CTI harnesses double diffusion encoding (DDE) experiments, which were here improved for speed and minimal bias us…
Although the socket is critical in a prosthetic system for a person with limb amputation, the methods of its design are largely artisanal. A roadblock for a repeatable and quantitative socket design process is the lack of predictive and patient specific biomechanical models of the residuum. This study presents the evaluation of such a model using a combined experimental-numerical approach. The model geometry and tissue boundaries are derived from MRI. The soft tissue non-linear elastic and viscoelastic mechanical behavior was evaluated using inverse finite element analysis (FEA) of in-vivo ind…
Purpose: To enable rigid-body motion tolerant parallel volumetric magnetic resonance imaging by retrospective head motion correction on a variety of spatio-temporal scales and imaging sequences. Theory and methods: Tolerance against rigid-body motion is based on distributed and incoherent sampling orders for boosting a joint retrospective motion estimation and reconstruction framework. Motion resilience stems from the encoding redundancy in the data, as generally provided by the coil array. Hence, it does not require external sensors, navigators or training data, so the methodology is readily …
Purpose: Organ-at-risk (OAR) delineation is a key step for cone-beam CT (CBCT) based adaptive radiotherapy planning that can be a time-consuming, labor-intensive, and subject-to-variability process. We aim to develop a fully automated approach aided by synthetic MRI for rapid and accurate CBCT multi-organ contouring in head-and-neck (HN) cancer patients. MRI has superb soft-tissue contrasts, while CBCT offers bony-structure contrasts. Using the complementary information provided by MRI and CBCT is expected to enable accurate multi-organ segmentation in HN cancer patients. In our proposed metho…
Vortical blood flow in the human left ventricular (LV) inflow initiates from the mitral valve (MV) and evolves within the LV during diastolic E-filling. Hence, vortical flow links MV and LV hemodynamics. This study sought to elucidate and quantitatively characterize the in vivo 3D dynamics of LV vortical flow over E-filling and relation to MV-LV hemodynamic coupling using 4D Flow MRI flow field. 34 healthy volunteers and 5 example patients underwent 4D Flow MRI. Vortical blood flow evolution was mapped in the LV over E-wave using enstrophy density. A new dimensionless profile PMV-LV was derive…
Purpose: A combined diffusion-relaxometry MR acquisition and analysis pipeline for in-vivo human placenta, which allows for exploration of coupling between T2* and apparent diffusion coefficient (ADC) measurements in a sub 10 minute scan time. Methods: We present a novel acquisition combining a diffusion prepared spin-echo with subsequent gradient echoes. The placentas of 17 pregnant women were scanned in-vivo, including both healthy controls and participants with various pregnancy complications. We estimate the joint T2*-ADC spectra using an inverse Laplace transform. Results: T2*-ADC spectra…
Objective Maps of B0 field inhomogeneities are often used to improve MRI image quality, even in a retrospective fashion. These field inhomogeneities depend on the exact head position within the static field but acquiring field maps (FM) at every position is time consuming. Here we explore different ways to obtain B0 predictions at different head positions. Methods FM were predicted from iterative simulations with four field factors: 1) sample induced B0 field, 2) system's spherical harmonic shim field, 3) perturbing field originating outside the field of view, 4) sequence phase errors. The sim…
OBJECTIVE: 2D Ultrasound (US) imaging has been recently investigated as a more accessible alternative to 3D Magnetic Resonance Imaging (MRI) for the estimation of soft issue motion under external mechanical loading. In the context of pressure ulcer prevention, the aim of this pilot MRI study was to design an experiment to characterize the sacral soft tissue motion under a controlled mechanical loading. Such an experiment targeted the estimation of the discrepancy between tissue motion assessed using a 2D imaging modality (echography) versus tissue motion assessed using a (reference) 3D imaging…
Purpose: To introduce, develop, and evaluate a novel denoising technique for diffusion MRI that leverages non-linear redundancy in the data to boost the SNR while preserving signal information. Methods: We exploit non-linear redundancy of the dMRI data by means of Kernel Principal Component Analysis (KPCA), a non-linear generalization of PCAto reproducing kernel Hilbert spaces. By mapping the signal to a high-dimensional space, better redundancy is achieved despite nonlinearities in the data thereby enabling better denoising than linear PCA. We implement KPCA with a Gaussian kernel, with param…
Dynamic Contrast-enhanced magnetic resonance imaging (DCE-MRI) is a tissue perfusion imaging technique. Some versatile free-breathing DCE-MRI techniques combining compressed sensing (CS) and parallel imaging with golden-angle radial sampling have been developed to improve motion robustness with high spatial and temporal resolution. These methods have demonstrated good diagnostic performance in clinical setting, but the reconstruction quality will degrade at high acceleration rates and overall reconstruction time remains long. In this paper, we proposed a new parallel CS reconstruction model fo…
We present NMR measurements of the diffusion of hyperpolarized helium-3 in the human lung performed at fields much lower than those of conventional MRI scanners. The measurements were made on standing subjects using homebuilt apparatus operating at 3 mT. Oxygen-limited transverse relaxation (T2 up to 15-35 s) could be measured in-vivo. Accurate global diffusion measurements have been performed in-vivo and in-vitro. 1D ADC mapping with high SNR demonstrates the real possibility of performing quality lung imaging at extremely low fields.
Objective: Accurate estimation of SAR is critical to safeguarding vulnerable patients who require an MRI procedure. The increased static field strength and RF duty cycle capabilities in modern MRI scanners mean that systems can easily exceed safe SAR levels for patients. Advisory protocols routinely used to establish quality assurance protocols are not required to advise on the testing of MRI SAR levels and is not routinely measured in annual medical physics quality assurance checks. This study aims to develop a head phantom and protocol that can independently verify global SAR for MRI clinica…
Multi-contrast images are commonly acquired together to maximize complementary diagnostic information, albeit at the expense of longer scan times. A time-efficient strategy to acquire high-quality multi-contrast images is to accelerate individual sequences and then reconstruct undersampled data with joint regularization terms that leverage common information across contrasts. However, these terms can cause features that are unique to a subset of contrasts to leak into the other contrasts. Such leakage-of-features may appear as artificial tissues, thereby misleading diagnosis. The goal of this …
Department of Radiology, Massachusetts General Hospital(麻省总医院放射科);Radiology, Perelman School of Medicine, University of Pennsylvania(宾夕法尼亚大学佩雷尔曼医学院放射科)
In fetal-brain MRI, head-pose changes between prescription and acquisition present a challenge to obtaining the standard sagittal, coronal and axial views essential to clinical assessment. As motion limits acquisitions to thick slices that preclude retrospective resampling, technologists repeat ~55-second stack-of-slices scans (HASTE) with incrementally reoriented field of view numerous times, deducing the head pose from previous stacks. To address this inefficient workflow, we propose a robust head-pose detection algorithm using full-uterus scout scans (EPI) which take ~5 seconds to acquire. …
Object This study proposes a scale space based algorithm for automated segmentation of single-shot tagged images of modest SNR. Furthermore the algorithm was designed for analysis of discontinuous or shearing types of motion, i.e. segmentation of broken tag patterns. Materials and methods The proposed algorithm utilizes non-linear scale space for automatic segmentation of single-shot tagged images. The algorithm's ability to automatically segment tagged shearing motion was evaluated in a numerical simulation and in vivo. A typical shearing deformation was simulated in a Shepp-Logan phantom all…
Two different dynamic decoupling strategies, the classic CPMG and the more recently proposed UDD protocol are compared in the context of magnetic resonance imaging (MRI). Both sequences were implemented on a 3T human MRI system and relaxometry was performed for a variety of tissue-mimicking agar and agarose gels. We find that CPMG provides moderately better decoupling than \UDD. The results are consistent with experimental noise spectra obtained from \textit{in vivo} spectroscopy results, which suggest that the type of noise spectra obtained would favor \CPMG. Theoretical coherence pathway ana…
BigBrain-MR: a new digital phantom with anatomically-realistic magnetic resonance properties at 100-μm resolution for magnetic resonance methods development
Magnetic resonance imaging at microtesla fields is a promising imaging method that combines the pre-polarization technique and broadband signal reception by SQUID sensors to enable in vivo MRI at microtesla-range magnetic fields. Despite significant advances, the potential of microtesla MRI for biomedical imaging is limited by its insufficient signal-to-noise ratio due to a relatively low sample polarization. Dynamic nuclear polarization (DNP) is a widely used approach that allows polarization enhancement by two-four orders of magnitude without an increase in the polarizing field strength. In …
Magnetic resonance imaging (MRI) is a widely used biomedical imaging modality that derives much of its contrast from microscale magnetic field gradients in biological tissues. However, the connection between these sub-voxel field patterns and MRI contrast has not been studied experimentally. Here, we describe a new method to map subcellular magnetic fields in mammalian cells and tissues using nitrogen vacancy diamond magnetometry and connect these maps to voxel-scale MRI contrast, providing insights for in vivo imaging and contrast agent design.
In-vivo imaging of the human thalamus: a comprehensive evaluation of structural magnetic resonance imaging approaches for thalamic nuclei differentiation at 7T
Silicon-based micro and nanoparticles have gained popularity in a wide range of biomedical applications due to their biocompatibility and biodegradability in-vivo, as well as a flexible surface chemistry, which allows drug loading, functionalization and targeting. Here we report direct in-vivo imaging of hyperpolarized 29Si nuclei in silicon microparticles by MRI. Natural physical properties of silicon provide surface electronic states for dynamic nuclear polarization (DNP), extremely long depolarization times, insensitivity to the in-vivo environment or particle tumbling, and surfaces favorab…
In parallel magnetic resonance imaging (pMRI), to find a joint solution for the image and coil sensitivity functions is a nonlinear and nonconvex problem. A class of algorithms reconstruct sensitivity encoded images of the coils first followed by the magnitude only image reconstruction, e.g. GRAPPA. It is shown in this paper that, if only the magnitude image is reconstructed, there exists a convex solution space for the magnitude image and sensitivity encoded images. This solution space enables formulation of a regularized convex optimization problem and leads to a globally optimal and unique …
Human brain activity generates scalp potentials (electroencephalography EEG), intracranial potentials (iEEG), and external magnetic fields (magnetoencephalography MEG), all capable of being recorded, often simultaneously, for use in research and clinical applications. The so-called forward problem is the modeling of these fields at their sensors for a given putative neural source configuration. While early generations modeled the head as a simple set of isotropic spheres, today s ubiquitous magnetic resonance imaging (MRI) data allows detailed descriptions of head compartments with assigned is…
Compressed sensing has reinvigorated the field of non-Cartesian sampling in magnetic resonance imaging (MRI). Until now there has been no 3D radial view-order which meets all the desired characteristics for simultaneous dynamic/high-resolution imaging, such as for self-navigated motion-corrected high resolution neuroimaging. In this work, we examine the use of Hierarchical Equal Area iso-Latitude Pixelization (HEALPix) for generation of three-dimensional (3D) radial view-orders for MRI, and compare to a selection of commonly used 3D view-orders. The resulting trajectories were evaluated throug…
Cross-term spatiotemporal encoding (xSPEN) is a recently introduced imaging approach delivering single-scan 2D NMR images with unprecedented resilience to field inhomogeneities. The method relies on performing a pre-acquisition encoding and a subsequent image read out while using the disturbing frequency inhomogeneities as part of the image formation processes, rather than as artifacts to be overwhelmed by the application of external gradients. This study introduces the use of this new single-shot MRI technique as a diffusion-monitoring tool, for accessing regions that have hitherto been unapp…
In this article, we present an up-to-date overview of the potential biomedical applications of sodium MRI in vivo. Sodium MRI is a subject of increasing interest in translational research as it can give some direct and quantitative biochemical information on the tissue viability, cell integrity and function, and therefore not only help the diagnosis but also the prognosis of diseases and treatment outcomes. It has already been applied in vivo in most of human tissues, such as brain for stroke or tumor detection and therapeutic response, in breast cancer, in articular cartilage, in muscle and i…
Chemical Exchange Saturation Transfer (CEST) Magnetic Resonance Imaging (MRI) is a molecular imaging methodology capable of mapping brain metabolites with relatively high spatial resolution. Specificity is the main goal of such experiments; yet CEST is confounded by spectral overlap between different molecular species. Here, we overcome this major limitation using a general framework termed overlap-resolved CEST (orCEST) - a kind of spectrally-edited experiment restoring specificity. First, we present evidence revealing that CEST experiments targeting the central nervous system's primary excit…