Arterial spin labeling (ASL) allows to quantify the cerebral blood flow (CBF) by magnetic labeling of the arterial blood water. ASL is increasingly used in clinical studies due to its noninvasiveness, repeatability and benefits in quantification. However, ASL suffers from an inherently low-signal-to-noise ratio (SNR) requiring repeated measurements of control/spin-labeled (C/L) pairs to achieve a reasonable image quality, which in return increases motion sensitivity. This leads to clinically prolonged scanning times increasing the risk of motion artifacts. Thus, there is an immense need of advanced imaging and processing techniques in ASL. In this paper, we propose a novel deep learning based approach to improve the perfusion-weighted image quality obtained from a subset of all available pairwise C/L subtractions. Specifically, we train a deep fully convolutional network (FCN) to learn a mapping from noisy perfusion-weighted image and its subtraction (residual) from the clean image. Additionally, we incorporate the CBF estimation model in the loss function during training, which enables the network to produce high quality images while simultaneously enforcing the CBF estimates to be as close as reference CBF values. Extensive experiments on synthetic and clinical ASL datasets demonstrate the effectiveness of our method in terms of improved ASL image quality, accurate CBF parameter estimation and considerably small computation time during testing.
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”(乌克兰国立技术大学“伊戈尔·西科斯基基辅理工学院”)
Accurate detection of arterial input function is a crucial step in obtaining perfusion hemodynamic parameters using dynamic susceptibility contrast-enhanced magnetic resonance imaging. It is required as input for perfusion quantification and has a great impact on the result of the deconvolution operation. To improve the reproducibility and reliability of arterial input function detection, several semi- or fully automatic methods have been proposed. This study provides an overview of the current state of the field of arterial input function detection. Methods most commonly used for semi- and fu…
Tensor-based Multimodal Learning for Prediction of Pulmonary Arterial Wedge Pressure from Cardiac MRI
University of Sheffield(谢菲尔德大学);Sheffield Teaching Hospitals(谢菲尔德教学医院);INSIGNEO, Institute for in Silico Medicine, University of Sheffield(谢菲尔德大学INSIGNEO计算机模拟医学研究所);Centre for Machine Intelligence, University of Sheffield(谢菲尔德大学机器智能中心)
Stroke Locus Net: Occluded Vessel Localization from MRI Modalities
Department of Electrical Engineering, College of Engineering, Qatar University, Doha, Qatar(电气工程系,工程学院,卡塔尔大学,多哈,卡塔尔);Department of Mathematics and Statistics, College of Arts and Sciences, Qatar University, Doha, Qatar(数学与统计学系,艺术与科学学院,卡塔尔大学,多哈,卡塔尔)
本研究提出端到端深度学习流水线 Stroke Locus Net,结合 nnUNet 分割、动脉图谱与 pGAN 生成,仅用 MRI 扫描实现闭塞血管定位,为更快速的中风诊断提供潜力。
Arterial spin labeling perfusion MRI is a noninvasive technique for measuring quantitative cerebral blood flow (CBF), but the measurement is subject to a low signal-to-noise-ratio(SNR). Various post-processing methods have been proposed to denoise ASL MRI but only provide moderate improvement. Deep learning (DL) is an emerging technique that can learn the most representative signal from data without prior modeling which can be highly complex and analytically indescribable. The purpose of this study was to assess whether the record breaking performance of DL can be translated into ASL MRI denoi…
Eastern Hepatobiliary Surgery Hospital(东方肝胆外科医院);Ping An Technology(平安科技);Georgia Institute of Technology(佐治亚理工学院);PAII Inc.(PAII公司)
Objectives: to propose a fully-automatic computer-aided diagnosis (CAD) solution for liver lesion characterization, with uncertainty estimation. Methods: we enrolled 400 patients who had either liver resection or a biopsy and was diagnosed with either hepatocellular carcinoma (HCC), intrahepatic cholangiocarcinoma, or secondary metastasis, from 2006 to 2019. Each patient was scanned with T1WI, T2WI, T1WI venous phase (T2WI-V), T1WI arterial phase (T1WI-A), and DWI MRI sequences. We propose a fully-automatic deep CAD pipeline that localizes lesions from 3D MRI studies using key-slice parsing an…
Stanford University(斯坦福大学);GE Healthcare(通用电气医疗集团);University of California Riverside(加州大学河滨分校)
Accurate quantification of cerebral blood flow (CBF) is essential for the diagnosis and assessment of a wide range of neurological diseases. Positron emission tomography (PET) with radiolabeled water (15O-water) is considered the gold-standard for the measurement of CBF in humans. PET imaging, however, is not widely available because of its prohibitive costs and use of short-lived radiopharmaceutical tracers that typically require onsite cyclotron production. Magnetic resonance imaging (MRI), in contrast, is more readily accessible and does not involve ionizing radiation. This study presents a…
MRISegmentator-Abdomen: A Fully Automated Multi-Organ and Structure Segmentation Tool for T1-weighted Abdominal MRI
Radiology and Imaging Sciences(放射学与影像科学);National Institutes of Health Clinical Center(国家卫生研究院临床中心);Walter Reed National Military Medical Center(沃尔特·里德国家军事医学中心);Biostatistics and Clinical Epidemiology Services(生物统计与临床流行病学服务)
Mask-guided Data Augmentation for Multiparametric MRI Generation with a Rare Hepatocellular Carcinoma
Universidad Industrial de Santander(桑坦德工业大学);University of Toulouse(图卢兹大学);Université Paul Sabatier Toulouse 3(图卢兹第三大学(保罗·萨巴蒂埃大学));Bicêtre University Hospital(比塞特尔大学医院);Assistance publique des hôpitaux de Paris(巴黎公共援助医院);Université Claude Bernard Lyon 1(里昂第一大学(克洛德·贝尔纳里昂第一大学))
Triple-Phase Sequential Fusion Network for Hepatobiliary Phase Liver MRI Synthesis
Yu-Yue Pathology Research Center, Jinfeng Laboratory(于越病理研究中心,锦峰实验室);Department of Clinical Laboratory Medicine, The First Affiliated Hospital of Army Medical University(临床实验室医学部,陆军军医大学第一附属医院);Laboratory of Intelligent Collaborative Computing, University of Electronic Science and Technology of China(智能协同计算实验室,电子科技大学)
Center for Advanced Medical Computing and Analysis, Massachusetts General Hospital and Harvard Medical School(麻省总医院与哈佛医学院高级医学计算与分析中心);Gordon Center for Medical Imaging, Massachusetts General Hospital and Harvard Medical School(麻省总医院与哈佛医学院戈登医学成像中心)
Deep neural networks have been proved efficient for medical image denoising. Current training methods require both noisy and clean images. However, clean images cannot be acquired for many practical medical applications due to naturally noisy signal, such as dynamic imaging, spectral computed tomography, arterial spin labeling magnetic resonance imaging, etc. In this paper we proposed a training method which learned denoising neural networks from noisy training samples only. Training data in the acquisition domain was split to two subsets and the network was trained to map one noisy set to the…
Temple University(天普大学);University of Maryland School of Medicine(马里兰大学医学院)
Arterial spin labeling (ASL) perfusion MRI provides a non-invasive way to quantify cerebral blood flow (CBF) but it still suffers from a low signal-to-noise-ratio (SNR). Using deep machine learning (DL), several groups have shown encouraging denoising results. Interestingly, the improvement was obtained when the deep neural network was trained using noise-contaminated surrogate reference because of the lack of golden standard high quality ASL CBF images. More strikingly, the output of these DL ASL networks (ASLDN) showed even higher SNR than the surrogate reference. This phenomenon indicates a…
GreenRFM: Learning a resource-efficient radiology vision-language foundation model via supervision-centric pre-training
School of Biomedical Engineering, Division of Life Sciences and Medicine, University of Science and Technology of China (USTC)(生物医学工程学院,生命科学与医学系,中国科学技术大学);Center for Medical Imaging, Robotics, Analytic Computing & Learning (MIRACLE)(医学影像、机器人、分析计算与学习中心);Suzhou Institute for Advanced Research, USTC(苏州先进研究院,中国科学技术大学);Department of Radiology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, USTC(放射科,中国科学技术大学第一附属医院,生命科学与医学系,中国科学技术大学);T Magnetic Resonance Translational Medicine Research Center, Department of Radiology, The First Affiliated Hospital (Southwest Hospital) of Army Medical University(7T磁共振转化医学研究中心,放射科,中国医学大学第一附属医院(西南医院))
PAII Inc.(PAII公司);Shengjing Hospital of China Medical University(中国医科大学附属盛京医院);Changhai Hospital(长海医院);Ping An Technology Co., Ltd.(平安科技(深圳)有限公司)
Accurate and automated tumor segmentation is highly desired since it has the great potential to increase the efficiency and reproducibility of computing more complete tumor measurements and imaging biomarkers, comparing to (often partial) human measurements. This is probably the only viable means to enable the large-scale clinical oncology patient studies that utilize medical imaging. Deep learning approaches have shown robust segmentation performances for certain types of tumors, e.g., brain tumors in MRI imaging, when a training dataset with plenty of pixel-level fully-annotated tumor images…
Accuracy, Uncertainty, and Adaptability of Automatic Myocardial ASL Segmentation using Deep CNN
Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California(明希德电气与计算机工程系,维特比工程学院,南加州大学);Long Beach Memorial Medical Center, University of California Irvine(长滩纪念医疗中心,加州大学伊万尼耶分校)
Leiden University Medical Center(莱顿大学医学中心);Philips(飞利浦);Amsterdam University Medical Center(阿姆斯特丹大学医学中心);Delft University of Technology(代尔夫特理工大学)
Positron Emission Tomography (PET) is an imaging method that can assess physiological function rather than structural disturbances by measuring cerebral perfusion or glucose consumption. However, this imaging technique relies on injection of radioactive tracers and is expensive. On the contrary, Arterial Spin Labeling (ASL) MRI is a non-invasive, non-radioactive, and relatively cheap imaging technique for brain hemodynamic measurements, which allows quantification to some extent. In this paper we propose a convolutional neural network (CNN) based model for translating ASL to PET images, which …