Artifacts on magnetic resonance scans are a serious challenge for both radiologists and computer-aided diagnosis systems. Most commonly, artifacts are caused by motion of the patients, but can also arise from device-specific abnormalities such as noise patterns. Irrespective of the source, artifacts can not only render a scan useless, but can potentially induce misdiagnoses if left unnoticed. For instance, an artifact may masquerade as a tumor or other abnormality. Retrospective artifact correction (RAC) is concerned with removing artifacts after the scan has already been taken. In this work, we propose a method capable of retrospectively removing eight common artifacts found in native-resolution MR imagery. Knowledge of the presence or location of a specific artifact is not assumed and the system is, by design, capable of undoing interactions of multiple artifacts. Our method is realized through the design of a novel volumetric transformer-based neural network that generalizes a \emph{window-centered} approach popularized by the Swin transformer. Unlike Swin, our method is (i) natively volumetric, (ii) geared towards dense prediction tasks instead of classification, and (iii), uses a novel and more global mechanism to enable information exchange between windows. Our experiments show that our reconstructions are considerably better than those attained by ResNet, V-Net, MobileNet-v2, DenseNet, CycleGAN and BicycleGAN. Moreover, we show that the reconstructed images from our model improves the accuracy of FSL BET, a standard skull-stripping method typically applied in diagnostic workflows.
In the clinical setting of histopathology, whole-slide image (WSI) artifacts frequently arise, distorting regions of interest, and having a pernicious impact on WSI analysis. Image-to-image translation networks such as CycleGANs are in principle capable of learning an artifact removal function from unpaired data. However, we identify a surjection problem with artifact removal, and propose an weakly-supervised extension to CycleGAN to address this. We assemble a pan-cancer dataset comprising artifact and clean tiles from the TCGA database. Promising results highlight the soundness of our method…
For several years, numerous attempts have been made to reduce noise and artifacts in MRI. Although there have been many successful methods to address these problems, practical implementation for clinical images is still challenging because of its complicated mechanism. Recently, deep learning received considerable attention, emerging as a machine learning approach in delivering robust MR image processing. The purpose here is therefore to explore further and review noise and artifact reduction using deep learning for MRI.
Yonsei University(延世大学);GE Healthcare(通用电气医疗);Seoul National University Hospital(首尔大学医院)
In this paper, we develop an efficient retrospective deep learning method called stacked U-Nets with self-assisted priors to address the problem of rigid motion artifacts in MRI. The proposed work exploits the usage of additional knowledge priors from the corrupted images themselves without the need for additional contrast data. The proposed network learns missed structural details through sharing auxiliary information from the contiguous slices of the same distorted subject. We further design a refinement stacked U-Nets that facilitates preserving of the image spatial details and hence improv…
Artifacts are a common occurrence in Diffusion MRI (dMRI) scans. Identifying and removing them is essential to ensure the accuracy and viability of any post processing carried out on these scans. This makes QC (quality control) a crucial first step prior to any analysis of dMRI data. Several QC methods for artifact detection exist, however they suffer from problems like requiring manual intervention and the inability to generalize across different artifacts and datasets. In this paper, we propose an automated deep learning (DL) pipeline that utilizes a 3D-Densenet architecture to train a model…
Retrospective artifact correction (RAC) improves image quality post acquisition and enhances image usability. Recent machine learning driven techniques for RAC are predominantly based on supervised learning and therefore practical utility can be limited as data with paired artifact-free and artifact-corrupted images are typically insufficient or even non-existent. Here we show that unwanted image artifacts can be disentangled and removed from an image via an RAC neural network learned with unpaired data. This implies that our method does not require matching artifact-corrupted data to be eithe…
Facebook AI Research(Facebook人工智能研究);Facebook New York(纽约Facebook);NYU Grossman School of Medicine(纽约大学格罗斯曼医学院);Department of Radiology(放射科)
MRI images reconstructed from sub-sampled Cartesian data using deep learning techniques often show a characteristic banding (sometimes described as streaking), which is particularly strong in low signal-to-noise regions of the reconstructed image. In this work, we propose the use of an adversarial loss that penalizes banding structures without requiring any human annotation. Our technique greatly reduces the appearance of banding, without requiring any additional computation or post-processing at reconstruction time. We report the results of a blind comparison against a strong baseline by a gr…
Korea Advanced Institute of Science & Technology (KAIST)(韩国科学技术院)
Purpose: Compressed sensing MRI (CS-MRI) from single and parallel coils is one of the powerful ways to reduce the scan time of MR imaging with performance guarantee. However, the computational costs are usually expensive. This paper aims to propose a computationally fast and accurate deep learning algorithm for the reconstruction of MR images from highly down-sampled k-space data. Theory: Based on the topological analysis, we show that the data manifold of the aliasing artifact is easier to learn from a uniform subsampling pattern with additional low-frequency k-space data. Thus, we develop de…
MIT(麻省理工学院);Boston Children’s Hospital(波士顿儿童医院);Harvard Medical School(哈佛医学院)
Fetal MRI is heavily constrained by unpredictable and substantial fetal motion that causes image artifacts and limits the set of viable diagnostic image contrasts. Current mitigation of motion artifacts is predominantly performed by fast, single-shot MRI and retrospective motion correction. Estimation of fetal pose in real time during MRI stands to benefit prospective methods to detect and mitigate fetal motion artifacts where inferred fetal motion is combined with online slice prescription with low-latency decision making. Current developments of deep reinforcement learning (DRL), offer a nov…
University of Maryland School of Medicine(马里兰大学医学院);Pacific Northwest National Laboratory(太平洋西北国家实验室);University of Maryland, College Park(马里兰大学帕克分校)
Purpose To develop and evaluate a deep learning-based method (MC-Net) to suppress motion artifacts in brain magnetic resonance imaging (MRI). Methods MC-Net was derived from a UNet combined with a two-stage multi-loss function. T1-weighted axial brain images contaminated with synthetic motions were used to train the network. Evaluation used simulated T1 and T2-weighted axial, coronal, and sagittal images unseen during training, as well as T1-weighted images with motion artifacts from real scans. Performance indices included the peak signal to noise ratio (PSNR), structural similarity index mea…
Anatomically Faithful Artifact Suppression in SENSE Accelerated Brain MRI
East China Normal University(华东师范大学);Affiliated Hospital of Guizhou Medical University(贵州医科大学附属医院);West China Hospital, Sichuan University(四川大学华西医院);Chinese Academy of Medical Sciences(中国医学科学院);RadioDynamic Medical(镭动医疗);Lucile Packard Children’s Hospital(露西尔·帕卡德儿童医院)
Purpose: To improve the quality of images obtained via dynamic contrast-enhanced MRI (DCE-MRI) that include motion artifacts and blurring using a deep learning approach. Methods: A multi-channel convolutional neural network (MARC) based method is proposed for reducing the motion artifacts and blurring caused by respiratory motion in images obtained via DCE-MRI of the liver. The training datasets for the neural network included images with and without respiration-induced motion artifacts or blurring, and the distortions were generated by simulating the phase error in k-space. Patient studies we…
Ayandegan Institute of Higher Education(阿扬德甘高等教育学院);The University of New South Wales(新南威尔士大学)
In this paper, a filtering approach for the 3D magnetic resonance imaging (MRI) assuming a Rician model for noise is addressed. Our denoising method is based on the Conventional Approach (CA) proposed to deal with the noise issue in the squared domain of the acquired magnitude MRI, where the noise distribution follows a Chi-square model rather than the Rician one. In the CA filtering method, the local samples around each voxel is used to estimate the unknown signal value. Intrinsically, such a method fails to achieve the best results where the underlying signal values have different statistica…
Reconstruction of Cardiac Cine MRI Using Motion-Guided Deformable Alignment and Multi-Resolution Fusion
School of Health Science and Engineering, University of Shanghai for Science and Technology(上海理工大学健康科学与工程学院);ToolSensing Technologies Co., Ltd(拓深科技有限公司);School of Medical Instruments, Shanghai University of Medicine and Health Sciences(上海健康医学院医疗器械学院);Shanghai Key Laboratory of Multidimensional Information Processing, School of Communication & Electronic Engineering, East China Normal University(华东师范大学通信与电子工程学院多维信息处理上海重点实验室)
Philips Healthcare(飞利浦医疗);University of Washington(华盛顿大学)
Patient motion during the magnetic resonance imaging (MRI) acquisition process results in motion artifacts, which limits the ability of radiologists to provide a quantitative assessment of a condition visualized. Often times, radiologists either "see through" the artifacts with reduced diagnostic confidence, or the MR scans are rejected and patients are asked to be recalled and re-scanned. Presently, there are many published approaches that focus on MRI artifact detection and correction. However, the key question of the bias exhibited by these algorithms on motion corrupted MRI images is still…
Yale University(耶鲁大学);Chinese Academy of Sciences(中国科学院);Peng Cheng Laboratory(鹏城实验室)
MRI with multiple protocols is commonly used for diagnosis, but it suffers from a long acquisition time, which yields the image quality vulnerable to say motion artifacts. To accelerate, various methods have been proposed to reconstruct full images from under-sampled k-space data. However, these algorithms are inadequate for two main reasons. Firstly, aliasing artifacts generated in the image domain are structural and non-local, so that sole image domain restoration is insufficient. Secondly, though MRI comprises multiple protocols during one exam, almost all previous studies only employ the r…
University Medical Center Utrecht(乌得勒支大学医学中心);Wilhelmina Children’s Hospital(威廉明娜儿童医院);Utrecht University(乌得勒支大学)
MR images of fetuses allow clinicians to detect brain abnormalities in an early stage of development. The cornerstone of volumetric and morphologic analysis in fetal MRI is segmentation of the fetal brain into different tissue classes. Manual segmentation is cumbersome and time consuming, hence automatic segmentation could substantially simplify the procedure. However, automatic brain tissue segmentation in these scans is challenging owing to artifacts including intensity inhomogeneity, caused in particular by spontaneous fetal movements during the scan. Unlike methods that estimate the bias f…
Indian Institute of Information Technology and Management-Kerala(喀拉拉信息技术与管理学院)
The aim of this paper is to introduce procedural steps for extension of the 1D homodyne phase correction for k-space truncation in all gradient encoding directions. Compared to the existing method applied to 2D partial k-space, signal losses introduced by the phase correction filter is observed to be minimal for the extended approach. In addition, the modified form of phase correction mitigates Incidental Phase Artifacts (IPA) due to truncation. For parallel imaging with undersampling along phase encode direction, the extended homodyne filtering is shown to be effective for minimizing these ar…
Removing Motion Artifact in MRI by Using a Perceptual Loss Driven Deep Learning Framework
Institute of Magnetic Resonance and Molecular Imaging in Medicine(医学磁共振与分子成像研究所);Shanghai Key Laboratory of Magnetic Resonance(上海磁共振重点实验室);The First Affiliated Hospital of Naval Medical University Department of Radiology(海军医学院第一附属医院放射科);Laboratory for Intelligent Medical Imaging(智能医学成像实验室);Tsinghua Cross-Strait Research Institute(清华大学海峡研究院);RadioDynamic Medical(RadioDynamic医疗)
Parallel imaging is a widely-used technique to accelerate magnetic resonance imaging (MRI). However, current methods still perform poorly in reconstructing artifact-free MRI images from highly undersampled k-space data. Recently, implicit neural representation (INR) has emerged as a new deep learning paradigm for learning the internal continuity of an object. In this study, we adopted INR to parallel MRI reconstruction. The MRI image was modeled as a continuous function of spatial coordinates. This function was parameterized by a neural network and learned directly from the measured k-space it…
Deep Learning Assisted Outer Volume Removal for Highly-Accelerated Real-Time Dynamic MRI
Department of Electrical and Computer Engineering, University of Minnesota(电气与计算机工程系,明尼苏达大学);Center for Magnetic Resonance Research, University of Minnesota(磁共振研究中心,明尼苏达大学);Department of Imaging Physics, Delft University of Technology(成像物理系,代尔夫特理工大学);HollandPTC, Delft, the Netherlands(HollandPTC,代尔夫特,荷兰)
The volume estimation of brain regions from MRI data is a key problem in many clinical applications, where the acquisition of data at high spatial resolution is desirable. While parallel MRI and constrained image reconstruction algorithms can accelerate the scans, image reconstruction artifacts are inevitable, especially at high acceleration factors. We introduce a novel image domain deep-learning framework for calibrationless parallel MRI reconstruction, coupled with a segmentation network to improve image quality and to reduce the vulnerability of current segmentation algorithms to image art…
Optical coherence tomography angiography (OCTA) is an important imaging modality in many bioengineering tasks. The image quality of OCTA, however, is often degraded by Bulk Motion Artifacts (BMA), which are due to micromotion of subjects and typically appear as bright stripes surrounded by blurred areas. State-of-the-art methods usually treat BMA removal as a learning-based image inpainting problem, but require numerous training samples with nontrivial annotation. In addition, these methods discard the rich structural and appearance information carried in the BMA stripe region. To address thes…
Sun Yat-sen University(中山大学);The Chinese University of Hong Kong(香港中文大学);Royal Brompton Hospital(皇家布朗普顿医院);Imperial College London(伦敦帝国理工学院)
The long acquisition time has limited the accessibility of magnetic resonance imaging (MRI) because it leads to patient discomfort and motion artifacts. Although several MRI techniques have been proposed to reduce the acquisition time, compressed sensing in magnetic resonance imaging (CS-MRI) enables fast acquisition without compromising SNR and resolution. However, existing CS-MRI methods suffer from the challenge of aliasing artifacts. This challenge results in the noise-like textures and missing the fine details, thus leading to unsatisfactory reconstruction performance. To tackle this chal…
Sparsity-Driven Parallel Imaging Consistency for Improved Self-Supervised MRI Reconstruction
Department of Electrical \& Computer Engineering, University of Minnesota, MN, USA Center for Magnetic Resonance Research, University of Minnesota, MN, USA
Korea Advanced Institute of Science and Technology (KAIST)(韩国科学技术院);Korea Basic Science Institute(韩国基础科学研究所)
Accelerated magnetic resonance (MR) scan acquisition with compressed sensing (CS) and parallel imaging is a powerful method to reduce MR imaging scan time. However, many reconstruction algorithms have high computational costs. To address this, we investigate deep residual learning networks to remove aliasing artifacts from artifact corrupted images. The proposed deep residual learning networks are composed of magnitude and phase networks that are separately trained. If both phase and magnitude information are available, the proposed algorithm can work as an iterative k-space interpolation algo…
Magnetic resonance imaging (MRI) is one of the most commonly applied tests in neurology and neurosurgery. However, the utility of MRI is largely limited by its long acquisition time, which might induce many problems including patient discomfort and motion artifacts. Acquiring fewer k-space sampling is a potential solution to reducing the total scanning time. However, it can lead to severe aliasing reconstruction artifacts and thus affect the clinical diagnosis. Nowadays, deep learning has provided new insights into the sparse reconstruction of MRI. In this paper, we present a new approach to t…
Endoscopic images typically contain several artifacts. The artifacts significantly impact image analysis result in computer-aided diagnosis. Convolutional neural networks (CNNs), a type of deep learning, can removes such artifacts. Various architectures have been proposed for the CNNs, and the accuracy of artifact removal varies depending on the choice of architecture. Therefore, it is necessary to determine the artifact removal accuracy, depending on the selected architecture. In this study, we focus on endoscopic surgical instruments as artifacts, and determine and discuss the artifact remov…
School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST)(韩国科学技术院电气工程学院)
An attention guided scheme for metal artifact correction in MRI using deep neural network is proposed in this paper. The inputs of the networks are two distorted images obtained with dual-polarity readout gradients. With MR image generation module and the additional data consistency loss to the previous work [1], the network is trained to estimate the frequency-shift map, off-resonance map, and attention map. The attention map helps to produce better distortion-corrected images by weighting on more relevant distortion-corrected images where two distortion-corrected images are produced with hal…
Wangxuan Institute of Computer Technology, Peking University(北京大学王选计算机技术研究所);State Key Laboratory of Digital Publishing Technology, Peking University Founder Group Co., Ltd.(北京大学方正集团有限公司数字出版技术国家重点实验室);School of Electrical and Electronic Engineering, Nanyang Technological University(南洋理工大学电气与电子工程学院)
Lossy compression brings artifacts into the compressed image and degrades the visual quality. In recent years, many compression artifacts removal methods based on convolutional neural network (CNN) have been developed with great success. However, these methods usually train a model based on one specific value or a small range of quality factors. Obviously, if the test image's quality factor does not match to the assumed value range, then degraded performance will be resulted. With this motivation and further consideration of practical usage, a highly robust compression artifacts removal networ…
The k-space data generated from magnetic resonance imaging (MRI) is only a finite sampling of underlying signals. Therefore, MRI images often suffer from low spatial resolution and Gibbs ringing artifacts. Previous studies tackled these two problems separately, where super resolution methods tend to enhance Gibbs artifacts, whereas Gibbs ringing removal methods tend to blur the images. It is also a challenge that high resolution ground truth is hard to obtain in clinical MRI. In this paper, we propose an unsupervised learning framework for both MRI super resolution and Gibbs artifacts removal …
We develop and evaluate a neural network-based method for Gibbs artifact and noise removal. A convolutional neural network (CNN) was designed for artifact removal in diffusion-weighted imaging data. Two implementations were considered: one for magnitude images and one for complex images. Both models were based on the same encoder-decoder structure and were trained by simulating MRI acquisitions on synthetic non-MRI images. Both machine learning methods were able to mitigate artifacts in diffusion-weighted images and diffusion parameter maps. The CNN for complex images was also able to reduce a…
Fordham University(福特汉姆大学);QS Investors, LLC(QS投资有限责任公司);Grossman Medical School(格罗斯曼医学院)
In-scanner motion degrades the quality of magnetic resonance imaging (MRI) thereby reducing its utility in the detection of clinically relevant abnormalities. We introduce a deep learning-based MRI artifact reduction model (DMAR) to localize and correct head motion artifacts in brain MRI scans. Our approach integrates the latest advances in object detection and noise reduction in Computer Vision. Specifically, DMAR employs a two-stage approach: in the first, degraded regions are detected using the Single Shot Multibox Detector (SSD), and in the second, the artifacts within the found regions ar…
Training a single deep blind model to handle different quality factors for JPEG image artifacts removal has been attracting considerable attention due to its convenience for practical usage. However, existing deep blind methods usually directly reconstruct the image without predicting the quality factor, thus lacking the flexibility to control the output as the non-blind methods. To remedy this problem, in this paper, we propose a flexible blind convolutional neural network, namely FBCNN, that can predict the adjustable quality factor to control the trade-off between artifacts removal and deta…
Flare spot is one type of flare artifact caused by a number of conditions, frequently provoked by one or more high-luminance sources within or close to the camera field of view. When light rays coming from a high-luminance source reach the front element of a camera, it can produce intra-reflections within camera elements that emerge at the film plane forming non-image information or flare on the captured image. Even though preventive mechanisms are used, artifacts can appear. In this paper, we propose a robust computational method to automatically detect and remove flare spot artifacts. Our co…
University of Science and Technology of China(中国科学技术大学)
Geometry-based point cloud compression (G-PCC) can achieve remarkable compression efficiency for point clouds. However, it still leads to serious attribute compression artifacts, especially under low bitrate scenarios. In this paper, we propose a Multi-Scale Graph Attention Network (MS-GAT) to remove the artifacts of point cloud attributes compressed by G-PCC. We first construct a graph based on point cloud geometry coordinates and then use the Chebyshev graph convolutions to extract features of point cloud attributes. Considering that one point may be correlated with points both near and far …
A Dual-domain Regularization Method for Ring Artifact Removal of X-ray CT
School of Mathematical Sciences, Capital Normal University(首都师范大学数学科学学院);Beijing Advanced Innovation Center for Imaging Technology, Capital Normal University(首都师范大学北京成像技术高精尖创新中心)
Korea Advanced Institute of Science and Technology (KAIST)(韩国科学技术院);Seoul National University College of Medicine(首尔大学医学院)
Diffusion-weighted MRI is nowadays performed routinely due to its prognostic ability, yet the quality of the scans are often unsatisfactory which can subsequently hamper the clinical utility. To overcome the limitations, here we propose a fully unsupervised quality enhancement scheme, which boosts the resolution and removes the motion artifact simultaneously. This process is done by first training the network using optimal transport driven cycleGAN with stochastic degradation block which learns to remove aliasing artifacts and enhance the resolution, then using the trained network in the test …
Purpose: Point-of-care MRI requires operation outside of a faraday shielded room normally used to block image-degrading electromagnetic Interference (EMI). To address this, we introduce the EDITER method, an external sensor based dynamic EMI estimation and removal method to retrospectively remove time-varying external interference sources. Theory and Methods: The method acquires data from multiple EMI detectors (tuned receive coils and electrodes placed on the body) simultaneous with the primary MR coil during image data acquisition. We dynamically calculate impulse response functions that map…
Recent advancements in the field of magnetic resonance imaging (MRI) have enabled large-scale collaboration among clinicians and researchers for neuroimaging tasks. However, researchers are often forced to use outdated and slow software to anonymize MRI images for publication. These programs specifically perform expensive mathematical operations over 3D images that rapidly slow down anonymization speed as an image's volume increases in size. In this paper, we introduce DeepDefacer, an application of deep learning to MRI anonymization that uses a streamlined 3D U-Net network to mask facial regi…
In clinical practice MR images are often first seen by radiologists long after the scan. If image quality is inadequate either patients have to return for an additional scan, or a suboptimal interpretation is rendered. An automatic image quality assessment (IQA) would enable real-time remediation. Existing IQA works for MRI give only a general quality score, agnostic to the cause of and solution to low-quality scans. Furthermore, radiologists' image quality requirements vary with the scan type and diagnostic task. Therefore, the same score may have different implications for different scans. W…
Rensselaer Polytechnic Institute(伦斯勒理工学院);Cedars-Sinai Medical Center(西达赛奈医疗中心);University of California, Los Angeles(加州大学洛杉矶分校)
Cine cardiac magnetic resonance imaging (MRI) is widely used for diagnosis of cardiac diseases thanks to its ability to present cardiovascular features in excellent contrast. As compared to computed tomography (CT), MRI, however, requires a long scan time, which inevitably induces motion artifacts and causes patients' discomfort. Thus, there has been a strong clinical motivation to develop techniques to reduce both the scan time and motion artifacts. Given its successful applications in other medical imaging tasks such as MRI super-resolution and CT metal artifact reduction, deep learning is a…