In clinical practice MR images are often first seen by radiologists long after the scan. If image quality is inadequate either patients have to return for an additional scan, or a suboptimal interpretation is rendered. An automatic image quality assessment (IQA) would enable real-time remediation. Existing IQA works for MRI give only a general quality score, agnostic to the cause of and solution to low-quality scans. Furthermore, radiologists' image quality requirements vary with the scan type and diagnostic task. Therefore, the same score may have different implications for different scans. We propose a framework with multi-task CNN model trained with calibrated labels and inferenced with image rulers. Labels calibrated by human inputs follow a well-defined and efficient labeling task. Image rulers address varying quality standards and provide a concrete way of interpreting raw scores from the CNN. The model supports assessments of two of the most common artifacts in MRI: noise and motion. It achieves accuracies of around 90%, 6% better than the best previous method examined, and 3% better than human experts on noise assessment. Our experiments show that label calibration, image rulers, and multi-task training improve the model's performance and generalizability.
The k-space data generated from magnetic resonance imaging (MRI) is only a finite sampling of underlying signals. Therefore, MRI images often suffer from low spatial resolution and Gibbs ringing artifacts. Previous studies tackled these two problems separately, where super resolution methods tend to enhance Gibbs artifacts, whereas Gibbs ringing removal methods tend to blur the images. It is also a challenge that high resolution ground truth is hard to obtain in clinical MRI. In this paper, we propose an unsupervised learning framework for both MRI super resolution and Gibbs artifacts removal …
Korea Advanced Institute of Science and Technology (KAIST)(韩国科学技术院);Seoul National University College of Medicine(首尔大学医学院)
Diffusion-weighted MRI is nowadays performed routinely due to its prognostic ability, yet the quality of the scans are often unsatisfactory which can subsequently hamper the clinical utility. To overcome the limitations, here we propose a fully unsupervised quality enhancement scheme, which boosts the resolution and removes the motion artifact simultaneously. This process is done by first training the network using optimal transport driven cycleGAN with stochastic degradation block which learns to remove aliasing artifacts and enhance the resolution, then using the trained network in the test …
Layer Selection in Feature-Based Losses Affects Image Quality and Microstructural Consistency in Deep Learning Super-Resolution of Brain Diffusion MRI
Institue for Applied Medical Informatics, University Medical Center Hamburg-Eppendorf(应用医学信息学研究所,汉堡大学医学中心);Institute of Computational Neuroscience, University Medical Center Hamburg-Eppendorf(计算神经科学研究所,汉堡大学医学中心);Center for Biomedical Artificial Intelligence (bAIome), University Medical Center Hamburg-Eppendorf(生物医学人工智能中心(bAIome),汉堡大学医学中心)
MIT(麻省理工学院);Boston Children’s Hospital(波士顿儿童医院);Harvard Medical School(哈佛医学院)
Fetal brain MRI is useful for diagnosing brain abnormalities but is challenged by fetal motion. The current protocol for T2-weighted fetal brain MRI is not robust to motion so image volumes are degraded by inter- and intra- slice motion artifacts. Besides, manual annotation for fetal MR image quality assessment are usually time-consuming. Therefore, in this work, a semi-supervised deep learning method that detects slices with artifacts during the brain volume scan is proposed. Our method is based on the mean teacher model, where we not only enforce consistency between student and teacher model…
Fudan University(复旦大学);Imperial College London(帝国理工学院);University of Oxford(牛津大学);Zhongshan Hospital Affiliated to Fudan University(复旦大学附属中山医院)
The quality of cardiac magnetic resonance (CMR) imaging is susceptible to respiratory motion artifacts. The model robustness of automated segmentation techniques in face of real-world respiratory motion artifacts is unclear. This manuscript describes the design of extreme cardiac MRI analysis challenge under respiratory motion (CMRxMotion Challenge). The challenge aims to establish a public benchmark dataset to assess the effects of respiratory motion on image quality and examine the robustness of segmentation models. The challenge recruited 40 healthy volunteers to perform different breath-ho…
Meta-learning Slice-to-Volume Reconstruction in Fetal Brain MRI using Implicit Neural Representations
School of Computation, Information and Technology, and School of Medicine and Health, Technical University Munich(计算、信息与技术学院,以及医学与健康学院,技术大学慕尼黑);CIBM Center for Biomedical Imaging and Radiology Department of Lausanne University Hospital and University of Lausanne(日内瓦大学医院与日内瓦大学生物医学影像与放射学中心部门);Centre for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King’s College London(发展脑中心,生物医学工程与影像科学学院,伦敦国王学院);Biomedical Image Technologies, ETSI Telecomunicación, Universidad Politécnica de Madrid(生物医学影像技术,电信工程学院,马德里理工大学);Department of Computing, Imperial College London(计算学院,伦敦帝国学院)
Shanghai Starriver Bilingual School(上海星河湾双语学校);University of California, Los Angeles(加利福尼亚大学洛杉矶分校)
Magnetic Resonance Imaging (MRI) is important in clinic to produce high resolution images for diagnosis, but its acquisition time is long for high resolution images. Deep learning based MRI super resolution methods can reduce scan time without complicated sequence programming, but may create additional artifacts due to the discrepancy between training data and testing data. Data consistency layer can improve the deep learning results but needs raw k-space data. In this work, we propose a magnitude-image based data consistency deep learning MRI super resolution method to improve super resolutio…
Four-dimensional magnetic resonance imaging (4D-MRI) is an emerging technique for tumor motion management in image-guided radiation therapy (IGRT). However, current 4D-MRI suffers from low spatial resolution and strong motion artifacts owing to the long acquisition time and patients' respiratory variations; these limitations, if not managed properly, can adversely affect treatment planning and delivery in IGRT. Herein, we developed a novel deep learning framework called the coarse-super-resolution-fine network (CoSF-Net) to achieve simultaneous motion estimation and super-resolution in a unifi…
Harbin Institute of Technology(哈尔滨工业大学);Inception Institute of Artificial Intelligence(起源人工智能研究院);Nanjing Medical University(南京医科大学)
The core problem of Magnetic Resonance Imaging (MRI) is the trade off between acceleration and image quality. Image reconstruction and super-resolution are two crucial techniques in Magnetic Resonance Imaging (MRI). Current methods are designed to perform these tasks separately, ignoring the correlations between them. In this work, we propose an end-to-end task transformer network (T$^2$Net) for joint MRI reconstruction and super-resolution, which allows representations and feature transmission to be shared between multiple task to achieve higher-quality, super-resolved and motion-artifacts-fr…
Bridging Single Distortion Artifacts and Multifactorial Clinical Quality: Few-shot Biparametric MRI Quality Assessment via Distortion-trained Prototypical Networks
UCL Hawkes Institute(UCL Hawkes研究所);Department of Medical Physics and Biomedical Engineering(医学物理与生物医学工程系);University College London(伦敦大学学院);Division of Surgery and Interventional Science(外科与介入科学分会);Centre for Medical Imaging(医学成像中心);British Urology Researchers in Surgical Training (BURST)(英国泌尿外科手术培训研究人员(BURST));Department of Radiology(放射科);University College London Hospitals NHS Foundation Trust(伦敦大学学院医院国家健康服务信托基金);Centre of Medical Imaging, Division of Medicine(医学成像中心,医学分会);Centre for Medical Image Computing(医学图像计算中心);Department of Computer Science(计算机科学系);Department of Urology(泌尿科)
Magnetic Resonance Imaging (MRI) is considered today the golden-standard modality for soft tissues. The long acquisition times, however, make it more prone to motion artifacts as well as contribute to the relatively high costs of this examination. Over the years, multiple studies concentrated on designing reduced measurement schemes and image reconstruction schemes for MRI, however, these problems have been so far addressed separately. On the other hand, recent works in optical computational imaging have demonstrated growing success of the simultaneous learning-based design of the acquisition …
For several years, numerous attempts have been made to reduce noise and artifacts in MRI. Although there have been many successful methods to address these problems, practical implementation for clinical images is still challenging because of its complicated mechanism. Recently, deep learning received considerable attention, emerging as a machine learning approach in delivering robust MR image processing. The purpose here is therefore to explore further and review noise and artifact reduction using deep learning for MRI.
School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST)(韩国科学技术院电气工程学院)
An attention guided scheme for metal artifact correction in MRI using deep neural network is proposed in this paper. The inputs of the networks are two distorted images obtained with dual-polarity readout gradients. With MR image generation module and the additional data consistency loss to the previous work [1], the network is trained to estimate the frequency-shift map, off-resonance map, and attention map. The attention map helps to produce better distortion-corrected images by weighting on more relevant distortion-corrected images where two distortion-corrected images are produced with hal…
Retrospective artifact correction (RAC) improves image quality post acquisition and enhances image usability. Recent machine learning driven techniques for RAC are predominantly based on supervised learning and therefore practical utility can be limited as data with paired artifact-free and artifact-corrupted images are typically insufficient or even non-existent. Here we show that unwanted image artifacts can be disentangled and removed from an image via an RAC neural network learned with unpaired data. This implies that our method does not require matching artifact-corrupted data to be eithe…
Fordham University(福特汉姆大学);QS Investors, LLC(QS投资有限责任公司);Grossman Medical School(格罗斯曼医学院)
In-scanner motion degrades the quality of magnetic resonance imaging (MRI) thereby reducing its utility in the detection of clinically relevant abnormalities. We introduce a deep learning-based MRI artifact reduction model (DMAR) to localize and correct head motion artifacts in brain MRI scans. Our approach integrates the latest advances in object detection and noise reduction in Computer Vision. Specifically, DMAR employs a two-stage approach: in the first, degraded regions are detected using the Single Shot Multibox Detector (SSD), and in the second, the artifacts within the found regions ar…
Yonsei University(延世大学);GE Healthcare(通用电气医疗);Seoul National University Hospital(首尔大学医院)
In this paper, we develop an efficient retrospective deep learning method called stacked U-Nets with self-assisted priors to address the problem of rigid motion artifacts in MRI. The proposed work exploits the usage of additional knowledge priors from the corrupted images themselves without the need for additional contrast data. The proposed network learns missed structural details through sharing auxiliary information from the contiguous slices of the same distorted subject. We further design a refinement stacked U-Nets that facilitates preserving of the image spatial details and hence improv…
Artifacts are a common occurrence in Diffusion MRI (dMRI) scans. Identifying and removing them is essential to ensure the accuracy and viability of any post processing carried out on these scans. This makes QC (quality control) a crucial first step prior to any analysis of dMRI data. Several QC methods for artifact detection exist, however they suffer from problems like requiring manual intervention and the inability to generalize across different artifacts and datasets. In this paper, we propose an automated deep learning (DL) pipeline that utilizes a 3D-Densenet architecture to train a model…
The University of Hong Kong(香港大学);Imperial College London(帝国理工学院)
Abdominal magnetic resonance imaging (MRI) provides a straightforward way of characterizing tissue and locating lesions of patients as in standard diagnosis. However, abdominal MRI often suffers from respiratory motion artifacts, which leads to blurring and ghosting that significantly deteriorate the imaging quality. Conventional methods to reduce or eliminate these motion artifacts include breath holding, patient sedation, respiratory gating, and image post-processing, but these strategies inevitably involve extra scanning time and patient discomfort. In this paper, we propose a novel deep-le…
KTH Royal Institute of Technology(KTH皇家理工学院);Science for Life Laboratory(生命科学实验室)
Artifacts on magnetic resonance scans are a serious challenge for both radiologists and computer-aided diagnosis systems. Most commonly, artifacts are caused by motion of the patients, but can also arise from device-specific abnormalities such as noise patterns. Irrespective of the source, artifacts can not only render a scan useless, but can potentially induce misdiagnoses if left unnoticed. For instance, an artifact may masquerade as a tumor or other abnormality. Retrospective artifact correction (RAC) is concerned with removing artifacts after the scan has already been taken. In this work, …
Rensselaer Polytechnic Institute(伦斯勒理工学院);Cedars-Sinai Medical Center(西达赛奈医疗中心);University of California, Los Angeles(加州大学洛杉矶分校)
Cine cardiac magnetic resonance imaging (MRI) is widely used for diagnosis of cardiac diseases thanks to its ability to present cardiovascular features in excellent contrast. As compared to computed tomography (CT), MRI, however, requires a long scan time, which inevitably induces motion artifacts and causes patients' discomfort. Thus, there has been a strong clinical motivation to develop techniques to reduce both the scan time and motion artifacts. Given its successful applications in other medical imaging tasks such as MRI super-resolution and CT metal artifact reduction, deep learning is a…
We develop and evaluate a neural network-based method for Gibbs artifact and noise removal. A convolutional neural network (CNN) was designed for artifact removal in diffusion-weighted imaging data. Two implementations were considered: one for magnitude images and one for complex images. Both models were based on the same encoder-decoder structure and were trained by simulating MRI acquisitions on synthetic non-MRI images. Both machine learning methods were able to mitigate artifacts in diffusion-weighted images and diffusion parameter maps. The CNN for complex images was also able to reduce a…
Philips Healthcare(飞利浦医疗);University of Washington(华盛顿大学)
Patient motion during the magnetic resonance imaging (MRI) acquisition process results in motion artifacts, which limits the ability of radiologists to provide a quantitative assessment of a condition visualized. Often times, radiologists either "see through" the artifacts with reduced diagnostic confidence, or the MR scans are rejected and patients are asked to be recalled and re-scanned. Presently, there are many published approaches that focus on MRI artifact detection and correction. However, the key question of the bias exhibited by these algorithms on motion corrupted MRI images is still…
MIT(麻省理工学院);Boston Children’s Hospital(波士顿儿童医院);Harvard Medical School(哈佛医学院)
Fetal MRI is heavily constrained by unpredictable and substantial fetal motion that causes image artifacts and limits the set of viable diagnostic image contrasts. Current mitigation of motion artifacts is predominantly performed by fast, single-shot MRI and retrospective motion correction. Estimation of fetal pose in real time during MRI stands to benefit prospective methods to detect and mitigate fetal motion artifacts where inferred fetal motion is combined with online slice prescription with low-latency decision making. Current developments of deep reinforcement learning (DRL), offer a nov…
University of Maryland School of Medicine(马里兰大学医学院);Pacific Northwest National Laboratory(太平洋西北国家实验室);University of Maryland, College Park(马里兰大学帕克分校)
Purpose To develop and evaluate a deep learning-based method (MC-Net) to suppress motion artifacts in brain magnetic resonance imaging (MRI). Methods MC-Net was derived from a UNet combined with a two-stage multi-loss function. T1-weighted axial brain images contaminated with synthetic motions were used to train the network. Evaluation used simulated T1 and T2-weighted axial, coronal, and sagittal images unseen during training, as well as T1-weighted images with motion artifacts from real scans. Performance indices included the peak signal to noise ratio (PSNR), structural similarity index mea…
Anatomically Faithful Artifact Suppression in SENSE Accelerated Brain MRI
East China Normal University(华东师范大学);Affiliated Hospital of Guizhou Medical University(贵州医科大学附属医院);West China Hospital, Sichuan University(四川大学华西医院);Chinese Academy of Medical Sciences(中国医学科学院);RadioDynamic Medical(镭动医疗);Lucile Packard Children’s Hospital(露西尔·帕卡德儿童医院)
Reconstruction of Cardiac Cine MRI Using Motion-Guided Deformable Alignment and Multi-Resolution Fusion
School of Health Science and Engineering, University of Shanghai for Science and Technology(上海理工大学健康科学与工程学院);ToolSensing Technologies Co., Ltd(拓深科技有限公司);School of Medical Instruments, Shanghai University of Medicine and Health Sciences(上海健康医学院医疗器械学院);Shanghai Key Laboratory of Multidimensional Information Processing, School of Communication & Electronic Engineering, East China Normal University(华东师范大学通信与电子工程学院多维信息处理上海重点实验室)
Image Sciences Institute, University Medical Center Utrecht(乌得勒支大学医学中心图像科学研究所);Wilhelmina Children’s Hospital, University Medical Center Utrecht(乌得勒支大学医学中心威廉明娜儿童医院);Brain Center Rudolf Magnus, University Medical Center Utrecht(乌得勒支大学医学中心鲁道夫·马格努斯脑中心)
Automatic neonatal brain tissue segmentation in preterm born infants is a prerequisite for evaluation of brain development. However, automatic segmentation is often hampered by motion artifacts caused by infant head movements during image acquisition. Methods have been developed to remove or minimize these artifacts during image reconstruction using frequency domain data. However, frequency domain data might not always be available. Hence, in this study we propose a method for removing motion artifacts from the already reconstructed MR scans. The method employs a generative adversarial network…
In magnetic resonance imaging (MRI), inhomogeneity in the main magnetic field used for imaging, referred to as off-resonance, can lead to image artifacts ranging from mild to severe depending on the application. Off-resonance artifacts, such as signal loss, geometric distortions, and blurring, can compromise the clinical and scientific utility of MR images. In this review, we describe sources of off-resonance in MRI, how off-resonance affects images, and strategies to prevent and correct for off-resonance. Given recent advances and the great potential of low field and/or portable MRI, we also …
Head motion during functional Magnetic Resonance Imaging acquisition can significantly contaminate the neural signal and introduce spurious, distance-dependent changes in signal correlations. This can heavily confound studies of development, aging, and disease. Previous approaches to suppress head motion artifacts have involved sequential regression of nuisance covariates, but this has been shown to reintroduce artifacts. We propose a new motion correction pipeline using an omnibus regression model that avoids this problem by simultaneously regressing out multiple artifacts using the best perf…
Deep Learning Assisted Outer Volume Removal for Highly-Accelerated Real-Time Dynamic MRI
Department of Electrical and Computer Engineering, University of Minnesota(电气与计算机工程系,明尼苏达大学);Center for Magnetic Resonance Research, University of Minnesota(磁共振研究中心,明尼苏达大学);Department of Imaging Physics, Delft University of Technology(成像物理系,代尔夫特理工大学);HollandPTC, Delft, the Netherlands(HollandPTC,代尔夫特,荷兰)
Gordon Center for Medical Imaging, Massachusetts General Hospital and Harvard Medical School(马萨诸塞总医院与哈佛医学院戈登医学影像中心);Texas A&M University(德克萨斯A&M大学);Texas A&M Institute of Data Science, Texas A&M University(德克萨斯A&M大学数据科学研究所);Texas A&M University at Qatar(德克萨斯A&M大学卡塔尔分校)
Magnetic resonance imaging (MRI) is one of the noninvasive imaging modalities that can produce high-quality images. However, the scan procedure is relatively slow, which causes patient discomfort and motion artifacts in images. Accelerating MRI hardware is constrained by physical and physiological limitations. A popular alternative approach to accelerated MRI is to undersample the k-space data. While undersampling speeds up the scan procedure, it generates artifacts in the images, and advanced reconstruction algorithms are needed to produce artifact-free images. Recently deep learning has emer…
Parallel imaging is a widely-used technique to accelerate magnetic resonance imaging (MRI). However, current methods still perform poorly in reconstructing artifact-free MRI images from highly undersampled k-space data. Recently, implicit neural representation (INR) has emerged as a new deep learning paradigm for learning the internal continuity of an object. In this study, we adopted INR to parallel MRI reconstruction. The MRI image was modeled as a continuous function of spatial coordinates. This function was parameterized by a neural network and learned directly from the measured k-space it…
The volume estimation of brain regions from MRI data is a key problem in many clinical applications, where the acquisition of data at high spatial resolution is desirable. While parallel MRI and constrained image reconstruction algorithms can accelerate the scans, image reconstruction artifacts are inevitable, especially at high acceleration factors. We introduce a novel image domain deep-learning framework for calibrationless parallel MRI reconstruction, coupled with a segmentation network to improve image quality and to reduce the vulnerability of current segmentation algorithms to image art…
University of Westminster(威斯敏斯特大学);Calico Life Sciences LLC(Calico生命科学有限责任公司)
Dixon MRI is widely used for body composition studies. Current processing methods associated with large whole-body volumes are time intensive and prone to artifacts during fat-water separation performed on the scanner, making the data difficult to analyse. The most common artifact are fat-water swaps, where the labels are inverted at the voxel level. It is common for researchers to discard swapped data (generally around 10%), which can be wasteful and lead to unintended biases. The UK Biobank is acquiring Dixon MRI for over 100,000 participants, and thousands of swaps will occur. If those go u…
Fluorine-19 (19F) MRI of injected perfluorocarbon emulsions (PFCs) allows for the non-invasive quantification of inflammation and cell tracking, but suffers from a low signal-to-noise ratio and extended scan time. To address this limitation, we tested the hypothesis that a 19F MRI pulse sequence that combines a specific undersampling regime with signal averaging has increased sensitivity and robustness against motion artifacts compared to a non-averaged fully-sampled dataset, when both are reconstructed with compressed sensing. To this end, numerical simulations and phantom experiments were pe…
Motion artifacts are a common occurrence in the Magnetic Resonance Imaging (MRI) exam. Motion during acquisition has a profound impact on workflow efficiency, often requiring a repeat of sequences. Furthermore, motion artifacts may escape notice by technologists, only to be revealed at the time of reading by the radiologists, affecting their diagnostic quality. Designing a computer-aided tool for automatic motion detection and elimination can improve the diagnosis, however, it needs a deep understanding of motion characteristics. Motion artifacts in MRI have a complex nature and it is directly…
Yale University(耶鲁大学);Chinese Academy of Sciences(中国科学院);Peng Cheng Laboratory(鹏城实验室)
MRI with multiple protocols is commonly used for diagnosis, but it suffers from a long acquisition time, which yields the image quality vulnerable to say motion artifacts. To accelerate, various methods have been proposed to reconstruct full images from under-sampled k-space data. However, these algorithms are inadequate for two main reasons. Firstly, aliasing artifacts generated in the image domain are structural and non-local, so that sole image domain restoration is insufficient. Secondly, though MRI comprises multiple protocols during one exam, almost all previous studies only employ the r…
Sparsity-Driven Parallel Imaging Consistency for Improved Self-Supervised MRI Reconstruction
Department of Electrical \& Computer Engineering, University of Minnesota, MN, USA Center for Magnetic Resonance Research, University of Minnesota, MN, USA
Motion Artifact Removal in Pixel-Frequency Domain via Alternate Masks and Diffusion Model
Xidian University(西安电子科技大学);Guangdong Provincial People’s Hospital(广东省人民医院);Southern Medical University(南方医科大学);Xiangyang No. 1 People’s Hospital(襄阳市第一人民医院);Hubei University of Medicine(湖北医药学院);Chongqing University of Posts and Telecommunications(重庆邮电大学)
We propose a new plug-and-play priors (PnP) based MR image reconstruction method that systematically enforces data consistency while also exploiting deep-learning priors. Our prior is specified through a convolutional neural network (CNN) trained without any artifact-free ground truth to remove undersampling artifacts from MR images. The results on reconstructing free-breathing MRI data into ten respiratory phases show that the method can form high-quality 4D images from severely undersampled measurements corresponding to acquisitions of about 1 and 2 minutes in length. The results also highli…
Sun Yat-sen University(中山大学);The Chinese University of Hong Kong(香港中文大学);Royal Brompton Hospital(皇家布朗普顿医院);Imperial College London(伦敦帝国理工学院)
The long acquisition time has limited the accessibility of magnetic resonance imaging (MRI) because it leads to patient discomfort and motion artifacts. Although several MRI techniques have been proposed to reduce the acquisition time, compressed sensing in magnetic resonance imaging (CS-MRI) enables fast acquisition without compromising SNR and resolution. However, existing CS-MRI methods suffer from the challenge of aliasing artifacts. This challenge results in the noise-like textures and missing the fine details, thus leading to unsatisfactory reconstruction performance. To tackle this chal…
University Medical Center Utrecht(乌得勒支大学医学中心);Wilhelmina Children’s Hospital(威廉明娜儿童医院);Utrecht University(乌得勒支大学)
MR images of fetuses allow clinicians to detect brain abnormalities in an early stage of development. The cornerstone of volumetric and morphologic analysis in fetal MRI is segmentation of the fetal brain into different tissue classes. Manual segmentation is cumbersome and time consuming, hence automatic segmentation could substantially simplify the procedure. However, automatic brain tissue segmentation in these scans is challenging owing to artifacts including intensity inhomogeneity, caused in particular by spontaneous fetal movements during the scan. Unlike methods that estimate the bias f…
22. Shortening acquisition time and reducing the motion-artifact are two of the most critical issues in MRI. As a promising solution, high-quality MRI image restoration provides a new approach to achieve higher resolution without costing additional acquisition time or modification on the pulse sequences. Recently, as to the rise of deep learning, convolutional neural networks have been proposed for super-resolution (SR) image generation and motion-artifact reduction (MAR) for MRI. Recent studies suggest that using perceptual feature space loss and k space loss to capture the perceptual informa…
Non-rigid Motion Correction for MRI Reconstruction via Coarse-To-Fine Diffusion Models
Department of Computing and Mathematical Sciences, Caltech(计算与数学科学部,加利福尼亚理工学院);Chandra Family Department of Electrical and Computer Engineering, UT Austin(查纳德家庭电子与计算机工程系,德克萨斯大学奥斯汀分校)
本文提出一种基于由粗到细扩散模型的交替最小化框架,通过优先重建低频分量来联合校正非刚性运动并重建欠采样 k 空间数据,在 64 倍欠采样下仍表现良好。