Physics-informed self-supervised deep learning reconstruction for accelerated first-pass perfusion cardiac MRI
Universidad de Valladolid(巴利亚多利德大学);King’s College London(伦敦国王学院);Instituto Superior Técnico, Universidade de Lisboa(里斯本大学高等技术学院);Centre for Marine Sciences - CCMAR(海洋科学中心(CCMAR))
Elena Martín-González, Ebraham Alskaf, Amedeo Chiribiri, Pablo Casaseca-de-la-Higuera, Carlos Alberola-López, Rita G Nunes, Teresa M Correia
备注:
Workshop on Machine Learning for Medical Image Reconstruction, MLMIR 2021, held in Conjunction with MICCAI 2021
发表信息:
In: Machine Learning for Medical Image Reconstruction. MLMIR 2021. Lecture Notes in Computer Science, vol 12964. Springer, Cham (2021)
First-pass perfusion cardiac magnetic resonance (FPP-CMR) is becoming an essential non-invasive imaging method for detecting deficits of myocardial blood flow, allowing the assessment of coronary heart disease. Nevertheless, acquisitions suffer from relatively low spatial resolution and limited heart coverage. Compressed sensing (CS) methods have been proposed to accelerate FPP-CMR and achieve higher spatial resolution. However, the long reconstruction times have limited the widespread clinical use of CS in FPP-CMR. Deep learning techniques based on supervised learning have emerged as alternatives for speeding up reconstructions. However, these approaches require fully sampled data for training, which is not possible to obtain, particularly high-resolution FPP-CMR images. Here, we propose a physics-informed self-supervised deep learning FPP-CMR reconstruction approach for accelerating FPP-CMR scans and hence facilitate high spatial resolution imaging. The proposed method provides high-quality FPP-CMR images from 10x undersampled data without using fully sampled reference data.
Motion free reconstruction of compressively sampled cardiac perfusion MR images is a challenging problem. It is due to the aliasing artifacts and the rapid contrast changes in the reconstructed perfusion images. In addition to the reconstruction limitations, many registration algorithms under perform in the presence of the rapid intensity changes. In this paper, we propose a novel motion correction method that reconstructs the motion free image series from the undersampled cardiac perfusion MR data. The motion correction method uses the novel robust principal component analysis based reconstru…
To our knowledge, all deep computer-aided detection and diagnosis (CAD) systems for prostate cancer (PCa) detection consider bi-parametric magnetic resonance imaging (bp-MRI) only, including T2w and ADC sequences while excluding the 4D perfusion sequence,which is however part of standard clinical protocols for this diagnostic task. In this paper, we question strategies to integrate information from perfusion imaging in deep neural architectures. To do so, we evaluate several ways to encode the perfusion information in a U-Net like architecture, also considering early versus mid fusion strategi…
Rensselaer Polytechnic Institute(伦斯勒理工学院);Cedars-Sinai Medical Center(西达赛奈医疗中心);University of California, Los Angeles(加州大学洛杉矶分校)
Cine cardiac magnetic resonance imaging (MRI) is widely used for diagnosis of cardiac diseases thanks to its ability to present cardiovascular features in excellent contrast. As compared to computed tomography (CT), MRI, however, requires a long scan time, which inevitably induces motion artifacts and causes patients' discomfort. Thus, there has been a strong clinical motivation to develop techniques to reduce both the scan time and motion artifacts. Given its successful applications in other medical imaging tasks such as MRI super-resolution and CT metal artifact reduction, deep learning is a…
King’s College London(伦敦国王学院);The Alan Turing Institute(艾伦·图灵研究所);Eindhoven University of Technology(埃因霍温理工大学);Philips Healthcare(飞利浦医疗)
The quantification of myocardial perfusion MRI has the potential to provide a fast, automated and user-independent assessment of myocardial ischaemia. However, due to the relatively high noise level and low temporal resolution of the acquired data and the complexity of the tracer-kinetic models, the model fitting can yield unreliable parameter estimates. A solution to this problem is the use of Bayesian inference which can incorporate prior knowledge and improve the reliability of the parameter estimation. This, however, uses Markov chain Monte Carlo sampling to approximate the posterior distr…
Eindhoven University of Technology(埃因霍温理工大学);King’s College London(伦敦国王学院);Philips Healthcare(飞利浦医疗)
Tracer-kinetic models allow for the quantification of kinetic parameters such as blood flow from dynamic contrast-enhanced magnetic resonance (MR) images. Fitting the observed data with multi-compartment exchange models is desirable, as they are physiologically plausible and resolve directly for blood flow and microvascular function. However, the reliability of model fitting is limited by the low signal-to-noise ratio, temporal resolution, and acquisition length. This may result in inaccurate parameter estimates. This study introduces physics-informed neural networks (PINNs) as a means to perf…
United Imaging Intelligence(联影智能);UIH America, Inc.(联影美国公司)
Real-time cardiac cine MRI does not require ECG gating in the data acquisition and is more useful for patients who can not hold their breaths or have abnormal heart rhythms. However, to achieve fast image acquisition, real-time cine commonly acquires highly undersampled data, which imposes a significant challenge for MRI image reconstruction. We propose a residual convolutional RNN for real-time cardiac cine reconstruction. To the best of our knowledge, this is the first work applying deep learning approach to Cartesian real-time cardiac cine reconstruction. Based on the evaluation from radiol…
University of Auckland(奥克兰大学);Johns Hopkins Medical Center(约翰斯·霍普金斯医疗中心);University of Wisconsin School of Medicine and Public Health(威斯康星大学医学与公共卫生学院);Aalborg University(奥尔堡大学);Auckland Bioengineering Institute(奥克兰生物工程研究所);Eindhoven University of Technology(埃因霍温理工大学)
The shape and motion of the heart provide essential clues to understanding the mechanisms of cardiovascular disease. With the advent of large-scale cardiac imaging data, statistical atlases become a powerful tool to provide automated and precise quantification of the status of patient-specific heart geometry with respect to reference populations. The Multi-Ethnic Study of Atherosclerosis (MESA), begun in 2000, was the first large cohort study to incorporate cardiovascular MRI in over 5000 participants, and there is now a wealth of follow-up data over 20 years. Building a machine learning based…
United Imaging Intelligence(联影智能);UIH America, Inc.(联影美国公司);United Imaging Healthcare(联影医疗)
Retrospectively gated cine (retro-cine) MRI is the clinical standard for cardiac functional analysis. Deep learning (DL) based methods have been proposed for the reconstruction of highly undersampled MRI data and show superior image quality and magnitude faster reconstruction time than CS-based methods. Nevertheless, it remains unclear whether DL reconstruction is suitable for cardiac function analysis. To address this question, in this study we evaluate and compare the cardiac functional values (EDV, ESV and EF for LV and RV, respectively) obtained from highly accelerated MRI acquisition usin…
Cardiac cine magnetic resonance imaging (MRI) can be considered the optimal criterion for measuring cardiac function. This imaging technique can provide us with detailed information about cardiac structure, tissue composition and even blood flow. This work considers the application of the higher order dynamic mode decomposition (HODMD) method to a set of MR images of a heart, with the ultimate goal of identifying the main patterns and frequencies driving the heart dynamics. A novel algorithm based on singular value decomposition combined with HODMD is introduced, providing a three-dimensional …
National Heart, Lung and Blood Institute, National Institutes of Health(美国国立卫生研究院国家心肺血液研究所);Barts Health NHS Trust(巴特保健国民保健信托基金);University of Leeds(利兹大学);Royal Free Hospital(皇家自由医院)
Recent development of quantitative myocardial blood flow (MBF) mapping allows direct evaluation of absolute myocardial perfusion, by computing pixel-wise flow maps. Clinical studies suggest quantitative evaluation would be more desirable for objectivity and efficiency. Objective assessment can be further facilitated by segmenting the myocardium and automatically generating reports following the AHA model. This will free user interaction for analysis and lead to a 'one-click' solution to improve workflow. This paper proposes a deep neural network based computational workflow for inline myocardi…
University of Notre Dame(圣母大学);Guangdong Cardiovascular Institute(广东省心血管病研究所);Guangdong Provincial People’s Hospital(广东省人民医院);Boston Children’s Hospital(波士顿儿童医院);Harvard Medical School(哈佛医学院);University of Pittsburgh(匹兹堡大学)
Real-time cardiac magnetic resonance imaging (MRI) plays an increasingly important role in guiding various cardiac interventions. In order to provide better visual assistance, the cine MRI frames need to be segmented on-the-fly to avoid noticeable visual lag. In addition, considering reliability and patient data privacy, the computation is preferably done on local hardware. State-of-the-art MRI segmentation methods mostly focus on accuracy only, and can hardly be adopted for real-time application or on local hardware. In this work, we present the first hardware-aware multi-scale neural archite…
Improved Robustness for Deep Learning-based Segmentation of Multi-Center Myocardial Perfusion MRI Datasets Using Data Adaptive Uncertainty-guided Space-time Analysis
Indiana University School of Medicine(印第安纳大学医学院);Purdue University(普渡大学);University of Calgary(卡尔加里大学);Cedars-Sinai Medical Center(西达赛奈医疗中心);Duke University(杜克大学);The Ohio State University(俄亥俄州立大学);Weill Cornell Medical Center(威尔康奈尔医学中心);OhioHealth(俄亥俄健康)
The goal of this project is to use magnetic resonance imaging (MRI) data to provide an end-to-end analytics pipeline for left and right ventricle (LV and RV) segmentation. Another aim of the project is to find a model that would be generalizable across medical imaging datasets. We utilized a variety of models, datasets, and tests to determine which one is well suited to this purpose. Specifically, we implemented three models (2-D U-Net, 3-D U-Net, and DenseNet), and evaluated them on four datasets (Automated Cardiac Diagnosis Challenge, MICCAI 2009 LV, Sunnybrook Cardiac Data, MICCAI 2012 RV).…
Echocardiography to Cardiac MRI View Transformation for Real-Time Blind Restoration
Tampere University(坦佩雷大学);Qatar University(卡塔尔大学);VTT Technical Research Centre of Finland(芬兰国家技术研究中心);Hamad Medical Corporation Hospital(哈马德医疗公司医院);Hayatabad Medical Complex(海亚特阿巴德医疗中心)
Imperial College London(帝国理工学院);Royal Brompton Hospital(皇家布朗普顿医院)
Segmentation of cardiac fibrosis and scar are essential for clinical diagnosis and can provide invaluable guidance for the treatment of cardiac diseases. Late Gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) has been successful for its efficacy in guiding the clinical diagnosis and treatment reliably. For LGE CMR, many methods have demonstrated success in accurately segmenting scarring regions. Co-registration with other non-contrast-agent (non-CA) modalities, balanced steady-state free precession (bSSFP) and cine magnetic resonance imaging (MRI) for example, can further en…
In most medical image processing tasks, the orientation of an image would affect computing result. However, manually reorienting images wastes time and effort. In this paper, we study the problem of recognizing orientation in cardiac MRI and using deep neural network to solve this problem. For multiple sequences and modalities of MRI, we propose a transfer learning strategy, which adapts our proposed model from a single modality to multiple modalities. We also propose a prediction method that uses voting. The results shows that deep neural network is an effective way in recognition of cardiac …
In recent years, convolutional neural networks have demonstrated promising performance in a variety of medical image segmentation tasks. However, when a trained segmentation model is deployed into the real clinical world, the model may not perform optimally. A major challenge is the potential poor-quality segmentations generated due to degraded image quality or domain shift issues. There is a timely need to develop an automated quality control method that can detect poor segmentations and feedback to clinicians. Here we propose a novel deep generative model-based framework for quality control …
School of Biomedical Engineering & Imaging Sciences, King’s College London, UK(伦敦国王学院生物医学工程与成像科学学院);Technical University of Munich, Germany(慕尼黑工业大学);Biomedical Image Analysis Group, Imperial College London, UK(帝国理工学院生物医学图像分析组);Department of Adult and Paediatric Cardiology, Guy’s and St Thomas’ NHS Foundation Trust, London, UK(盖伊和圣托马斯国民健康服务信托基金会成人及儿科心脏病科);Coimbra Institute for Biomedical Imaging and Translational Research, University of Coimbra, Portugal(科英布拉大学科英布拉生物医学成像与转化研究学院);Helmholtz Center Munich, Germany(慕尼黑亥姆霍兹中心)
Cine cardiac MRI is routinely acquired for the assessment of cardiac health, but the imaging process is slow and typically requires several breath-holds to acquire sufficient k-space profiles to ensure good image quality. Several undersampling-based reconstruction techniques have been proposed during the last decades to speed up cine cardiac MRI acquisition. However, the undersampling factor is commonly fixed to conservative values before acquisition to ensure diagnostic image quality, potentially leading to unnecessarily long scan times. In this paper, we propose an end-to-end quality-aware c…
Personalized Topology-Informed Localization of Standard 12-Lead ECG Electrode Placement from Incomplete Cardiac MRIs for Efficient Cardiac Digital Twins
School of Electronics & Computer Science, University of Southampton(南安普顿大学电子与计算机科学学院);University of Oxford(牛津大学);National University of Singapore(新加坡国立大学);School of Biomedical Engineering and Imaging Sciences, Kings College London(伦敦国王学院生物医学工程与影像科学学院)
Zhejiang University(浙江大学);University of Notre Dame(圣母大学)
Automatic segmentation of cardiac magnetic resonance imaging (MRI) facilitates efficient and accurate volume measurement in clinical applications. However, due to anisotropic resolution and ambiguous border (e.g., right ventricular endocardium), existing methods suffer from the degradation of accuracy and robustness in 3D cardiac MRI video segmentation. In this paper, we propose a novel Deformable U-Net (DeU-Net) to fully exploit spatio-temporal information from 3D cardiac MRI video, including a Temporal Deformable Aggregation Module (TDAM) and a Deformable Global Position Attention (DGPA) net…
Rutgers University(罗格斯大学);United Imaging Intelligence(联影智能);University of Illinois at Urbana-Champaign(伊利诺伊大学厄巴纳-香槟分校)
Accurate estimation of shape thickness from medical images is crucial in clinical applications. For example, the thickness of myocardium is one of the key to cardiac disease diagnosis. While mathematical models are available to obtain accurate dense thickness estimation, they suffer from heavy computational overhead due to iterative solvers. To this end, we propose novel methods for dense thickness estimation, including a fast solver that estimates thickness from binary annular shapes and an end-to-end network that estimates thickness directly from raw cardiac images.We test the proposed model…
In this paper, we study the problem of imaging orientation in cardiac MRI, and propose a framework to categorize the orientation for recognition and standardization via deep neural networks. The method uses a new multi-tasking strategy, where both the tasks of cardiac segmentation and orientation recognition are simultaneously achieved. For multiple sequences and modalities of MRI, we propose a transfer learning strategy, which adapts our proposed model from a single modality to multiple modalities. We embed the orientation recognition network in a Cardiac MRI Orientation Adjust Tool, i.e., CM…
University College London(伦敦大学学院);Centre for Medical Image Computing(医学图像计算中心)
Accurate segmentation of the right ventricle (RV) is a crucial step in the assessment of the ventricular structure and function. Yet, due to its complex anatomy and motion segmentation of the RV has not been as largely studied as the left ventricle. This paper presents a fully automatic method for the segmentation of the RV in cardiac magnetic resonance images (MRI). The method uses a coarse-to-fine segmentation strategy in combination with a multi-atlas propagation segmentation framework. Based on a cross correlation metric, our method selects the best atlases for propagation allowing the ref…
Low-rank tensor models have been applied in accelerating dynamic magnetic resonance imaging (dMRI). Recently, a new tensor nuclear norm based on t-SVD has been proposed and applied to tensor completion. Inspired by the different properties of the tensor nuclear norm (TNN) and the Casorati matrix nuclear norm (MNN), we introduce a combined TNN and Casorati MNN regularizations framework to reconstruct dMRI, which we term as TMNN. The proposed method simultaneously exploits the spatial structure and the temporal correlation of the dynamic MR data. The optimization problem can be efficiently solve…
Deep Separable Spatiotemporal Learning for Fast Dynamic Cardiac MRI
Xiamen University(厦门大学);Fudan University(复旦大学);Xiamen Cardiovascular Hospital of Xiamen University(厦门大学附属厦门心血管病医院);School of Medicine, Xiamen University(厦门大学医学院);Ruijin Hospital Lu Wan Branch, Shanghai Jiaotong University School of Medicine(上海交通大学医学院附属瑞金医院卢湾分院);Shanghai Institute of Cardiovascular Diseases(上海市心血管病研究所);Zhongshan Hospital, Fudan University(复旦大学附属中山医院);Shanghai Medical School, Fudan University(复旦大学上海医学院);Shanghai Institute of Medical Imaging(上海市医学影像研究所);Xiamen University of Technology(厦门理工学院);Imperial College London(帝国理工学院)
Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University(复旦大学类脑智能科学与技术研究院)
In this paper, the problem of orientation correction in cardiac MRI images is investigated and a framework for orientation recognition via deep neural networks is proposed. For multi-modality MRI, we introduce a transfer learning strategy to transfer our proposed model from single modality to multi-modality. We embed the proposed network into the orientation correction command-line tool, which can implement orientation correction on 2D DICOM and 3D NIFTI images. Our source code, network models and tools are available at https://github.com/Jy-stdio/MSCMR_orient/
Personalized 4D Whole Heart Geometry Reconstruction from Cine MRI for Cardiac Digital Twins
Department of Biomedical Engineering, National University of Singapore, Singapore(新加坡国立大学生物医学工程系);School of Data Science, Fudan University, Shanghai, China(复旦大学数据科学学院);Department of Engineering Science, University of Oxford, Oxford, UK(牛津大学工程科学系);Department of Medicine, National University of Singapore, Singapore(新加坡国立大学医学系);Department of Cardiology, National University Heart Centre Singapore, Singapore(新加坡国立心脏中心心内科部)
School of Biomedical Engineering and Imaging Sciences, King’s College London(伦敦国王学院生物医学工程与影像科学学院);The Alan Turing Institute(阿兰·图灵研究所);Philips Healthcare(飞利浦医疗保健);Eindhoven University of Technology(埃因霍温理工大学)
Purpose: Tracer-kinetic models can be used for the quantitative assessment of contrast-enhanced MRI data. However, the model-fitting can produce unreliable results due to the limited data acquired and the high noise levels. Such problems are especially prevalent in myocardial perfusion MRI leading to the compromise of constrained numerical deconvolutions and segmental signal averaging being commonly used as alternatives to the more complex tracer-kinetic models. Methods: In this work, the use of hierarchical Bayesian inference for the parameter estimation is explored. It is shown that with Bay…
University of Bourgogne Franche-Comte(勃艮第-弗朗什-孔泰大学);CASIS inc.(CASIS公司);University of Sherbrooke(舍布鲁克大学);University Hospital of Dijon(第戎大学医院)
Deep learning methods are the de-facto solutions to a multitude of medical image analysis tasks. Cardiac MRI segmentation is one such application which, like many others, requires a large number of annotated data so a trained network can generalize well. Unfortunately, the process of having a large number of manually curated images by medical experts is both slow and utterly expensive. In this paper, we set out to explore whether expert knowledge is a strict requirement for the creation of annotated datasets that machine learning can successfully train on. To do so, we gauged the performance o…
Accurate cardiac computing, analysis and modeling from multi-modality images are important for the diagnosis and treatment of cardiac disease. Late gadolinium enhancement magnetic resonance imaging (LGE MRI) is a promising technique to visualize and quantify myocardial infarction (MI) and atrial scars. Automating quantification of MI and atrial scars can be challenging due to the low image quality and complex enhancement patterns of LGE MRI. Moreover, compared with the other sequences LGE MRIs with gold standard labels are particularly limited, which represents another obstacle for developing …
Universitat Pompeu Fabra(庞培法布拉大学);BCN MedTech(巴塞罗那医疗科技中心);Queen Mary University of London(伦敦玛丽女王大学);William Harvey Research Institute(威廉·哈维研究所);Stanford University(斯坦福大学);Catalan Institution for Research and Advanced Studies (ICREA)(加泰罗尼亚研究与高级研究所)
Use expert visualization or conventional clinical indices can lack accuracy for borderline classications. Advanced statistical approaches based on eigen-decomposition have been mostly concerned with shape and motion indices. In this paper, we present a new approach to identify CVDs from cine-MRI by estimating large pools of radiomic features (statistical, shape and textural features) encoding relevant changes in anatomical and image characteristics due to CVDs. The calculated cine-MRI radiomic features are assessed using sequential forward feature selection to identify the most relevant ones f…
University of Notre Dame(圣母大学);IBM Thomas J. Watson Research Center(IBM托马斯·J·沃森研究中心);Guangdong General Hospital(广东省人民医院)
Cardiac magnetic resonance imaging (MRI) is an essential tool for MRI-guided surgery and real-time intervention. The MRI videos are expected to be segmented on-the-fly in real practice. However, existing segmentation methods would suffer from drastic accuracy loss when modified for speedup. In this work, we propose Multiscale Statistical U-Net (MSU-Net) for real-time 3D MRI video segmentation in cardiac surgical guidance. Our idea is to model the input samples as multiscale canonical form distributions for speedup, while the spatio-temporal correlation is still fully utilized. A parallel stati…
Universitat de Barcelona(巴塞罗那大学);Barts Health NHS Trust(巴特兹健康国民保健服务信托基金);Queen Mary University of London(伦敦玛丽女王大学);Universitat Pompeu Fabra(庞培法布拉大学);ICREA(加泰罗尼亚研究与高级研究院)
Accurate segmentation of the cardiac boundaries in late gadolinium enhancement magnetic resonance images (LGE-MRI) is a fundamental step for accurate quantification of scar tissue. However, while there are many solutions for automatic cardiac segmentation of cine images, the presence of scar tissue can make the correct delineation of the myocardium in LGE-MRI challenging even for human experts. As part of the Multi-Sequence Cardiac MR Segmentation Challenge, we propose a solution for LGE-MRI segmentation based on two components. First, a generative adversarial network is trained for the task o…
Cine cardiac MRI reconstruction using a convolutional recurrent network with refinement
Institute for Digital Communications, University of Edinburgh(爱丁堡大学数字通信研究所);Institute of Information Science and Technologies “Alessandro Faedo”, National Research Council of Italy (CNR)(意大利国家研究委员会信息科学与技术研究所(亚历山德罗·法埃多));Department of Information Engineering, University of Pisa(比萨大学信息工程系);Institute for Infrastructure and Environment, University of Edinburgh(爱丁堡大学基础设施与环境研究所);The Alan Turing Institute(阿兰·图灵研究所)
University of Notre Dame(圣母大学);Guangdong Provincial People’s Hospital(广东省人民医院);IBM Thomas J. Watson Research Center(IBM托马斯·J·沃森研究中心)
Real-time cine magnetic resonance imaging (MRI) plays an increasingly important role in various cardiac interventions. In order to enable fast and accurate visual assistance, the temporal frames need to be segmented on-the-fly. However, state-of-the-art MRI segmentation methods are used either offline because of their high computation complexity, or in real-time but with significant accuracy loss and latency increase (causing visually noticeable lag). As such, they can hardly be adopted to assist visual guidance. In this work, inspired by a new interpretation of Independent Component Analysis …
University of Sherbrooke(舍布鲁克大学);Université de Bourgogne Franche-Comté(勃艮第-弗朗什孔泰大学);CArdiac Simulation & Imaging Software(心脏模拟与成像软件公司);Université de Lyon(里昂大学)
Recent publications have shown that the segmentation accuracy of modern-day convolutional neural networks (CNN) applied on cardiac MRI can reach the inter-expert variability, a great achievement in this area of research. However, despite these successes, CNNs still produce anatomically inaccurate segmentations as they provide no guarantee on the anatomical plausibility of their outcome, even when using a shape prior. In this paper, we propose a cardiac MRI segmentation method which always produces anatomically plausible results. At the core of the method is an adversarial variational autoencod…
Automated segmentation of human cardiac magnetic resonance datasets has been steadily improving during recent years. However, these methods are not directly applicable in preclinical context due to limited datasets and lower image resolution. Successful application of deep architectures for rat cardiac segmentation, although of critical importance for preclinical evaluation of cardiac function, has to our knowledge not yet been reported. We developed segmentation models that expand on the standard U-Net architecture and evaluated separate models for systole and diastole phases, 2MSA, and one m…
Imperial College London(伦敦帝国理工学院);Royal Brompton and Harefield hospital(皇家布朗普顿与哈雷菲尔德医院);Technische Universität München (TUM)(慕尼黑工业大学(TUM))
Diffusion Tensor Cardiac Magnetic Resonance (DT-CMR) enables us to probe the microstructural arrangement of cardiomyocytes within the myocardium in vivo and non-invasively, which no other imaging modality allows. This innovative technology could revolutionise the ability to perform cardiac clinical diagnosis, risk stratification, prognosis and therapy follow-up. However, DT-CMR is currently inefficient with over six minutes needed to acquire a single 2D static image. Therefore, DT-CMR is currently confined to research but not used clinically. We propose to reduce the number of repetitions need…
Deep learning methods for classifying medical images have demonstrated impressive accuracy in a wide range of tasks but often these models are hard to interpret, limiting their applicability in clinical practice. In this work we introduce a convolutional neural network model for identifying disease in temporal sequences of cardiac MR segmentations which is interpretable in terms of clinically familiar measurements. The model is based around a variational autoencoder, reducing the input into a low-dimensional latent space in which classification occurs. We then use the recently developed `conce…
Perfusion MRI is an important modality in many brain imaging protocols, since it probes cerebrovascular changes in aging and many diseases; however, it may not be always available. Here we introduce a method that seeks to estimate regional perfusion properties using spectral information of resting-state functional MRI (rsfMRI) via machine learning. We used pairs of rsfMRI and arterial spin labeling (ASL) images from the same elderly individuals with normal cognition (NC; n = 45) and mild cognitive impairment (MCI; n = 26), and built support vector machine models aiming to estimate regional cer…
Automatic segmentation of myocardial contours and relevant areas like infraction and no-reflow is an important step for the quantitative evaluation of myocardial infarction. In this work, we propose a cascaded convolutional neural network for automatic myocardial infarction segmentation from delayed-enhancement cardiac MRI. We first use a 2D U-Net to focus on the intra-slice information to perform a preliminary segmentation. After that, we use a 3D U-Net to utilize the volumetric spatial information for a subtle segmentation. Our method is evaluated on the MICCAI 2020 EMIDEC challenge dataset …
Cardiac Magnetic Resonance Imaging (MRI) plays an important role in the analysis of cardiac function. However, the acquisition is often accompanied by motion artefacts because of the difficulty of breath-hold, especially for acute symptoms patients. Therefore, it is essential to assess the quality of cardiac MRI for further analysis. Time-consuming manual-based classification is not conducive to the construction of an end-to-end computer aided diagnostic system. To overcome this problem, an automatic cardiac MRI quality estimation framework using ensemble and transfer learning is proposed in t…
Massachusetts General Hospital(麻省总医院);Harvard Medical School(哈佛医学院);National Taiwan University(台湾大学);University of Southern California(南加州大学)
Assessment of cardiovascular disease (CVD) with cine magnetic resonance imaging (MRI) has been used to non-invasively evaluate detailed cardiac structure and function. Accurate segmentation of cardiac structures from cine MRI is a crucial step for early diagnosis and prognosis of CVD, and has been greatly improved with convolutional neural networks (CNN). There, however, are a number of limitations identified in CNN models, such as limited interpretability and high complexity, thus limiting their use in clinical practice. In this work, to address the limitations, we propose a lightweight and i…
University of Kansas(堪萨斯大学);Rochester Institute of Technology(罗切斯特理工学院)
Patient-specific left ventricle (LV) myocardial models have the potential to be used in a variety of clinical scenarios for improved diagnosis and treatment plans. Cine cardiac magnetic resonance (MR) imaging provides high resolution images to reconstruct patient-specific geometric models of the LV myocardium. With the advent of deep learning, accurate segmentation of cardiac chambers from cine cardiac MR images and unsupervised learning for image registration for cardiac motion estimation on a large number of image datasets is attainable. Here, we propose a deep leaning-based framework for th…