SPIDER负离子源中束发射光谱学的首批结果

First results from beam emission spectroscopy in SPIDER negative ion source

M. Barbisan, B. Zaniol, R. Pasqualotto, G. Serianni, M. Ugoletti

AI总结:

本文介绍了SPIDER负离子源中BES诊断系统的设置及首批实验结果,在无铯条件下表征了氢束特性,发现多普勒频移辐射强度与束流电流和发散度强相关,并研究了电压对束流偏转的补偿作用。

摘要:

SPIDER实验是位于意大利帕多瓦Consorzio RFX的Neutral Beam Test Facility (NBTF)的一部分,是ITER中性束注入器负离子源的原型;该源与一个100 kV三栅极加速系统耦合。在SPIDER中安装了Beam Emission Spectroscopy (BES)诊断系统,用于研究和优化从源中引出的H-/D-束的能量分布、瞄准、均匀性和发散度。该诊断基于对束流粒子与背景H2/D2分子相互作用时发射的多普勒频移Hα/Dα光的分析。2019年,SPIDER中的BES诊断系统被安装并校准,它允许在无铯条件下表征从SPIDER源引出的首批氢束。组成束的活跃束流数量从1280减少到80,影响了BES诊断能力。本文介绍了BES诊断设置并讨论了首批收集的结果。在有限的引出电流密度(约10 A/m^2)和离子能量(≤35 keV)下,未检测到由源中的磁场滤波场引起的显著垂直束偏转。在某些情况下,观察到束流在水平方向上被拉长;在垂直和水平方向上分别测量到低至20 mrad和30 mrad e-folding的束流发散值;发现多普勒频移辐射强度与束流电流和束流发散度强相关。研究了在引出间隙中随着电压增加而逐步补偿束流偏转(由电子抑制滤波场引起)的情况。

英文摘要:

The SPIDER experiment, part of the Neutral Beam Test Facility (NBTF) at Consorzio RFX (Padua, Italy), is the prototype of the negative ion source for the ITER neutral beam injectors; the source is coupled to a 100 kV three-grid acceleration system. A Beam Emission Spectroscopy (BES) diagnostic was installed in SPIDER to study and optimize energy distribution, aiming, uniformity and divergence of the H-/D- beam extracted from the source. The diagnostic is based on the analysis of the Doppler shifted Hα/Dα light emitted in the interaction between the beam particles and the H2/D2 molecules of the background. In 2019 the BES diagnostic in SPIDER was installed and calibrated, and it allowed to characterize the first hydrogen beams extracted from the SPIDER source, in cesium free conditions. The number of active beamlets composing the beam was reduced from 1280 to 80, affecting the BES diagnostic capabilities. This paper presents the BES diagnostic setup and discusses the first collected results. Under limited extracted current density ($\sim$ 10 A/m^2) and ion energy ($\leq$35 keV), no significant vertical beam deflection caused by the magnetic filter field in the source was detected. In some cases the beamlets were observed to be elongated in horizontal direction; beamlet divergence values down to 20 mrad and 30 mrad e-folding were measured in vertical and horizontal direction, respectively; the intensity of the Doppler shifted radiation was found to be strongly correlated to the beam current and to the beam divergence. The progressive compensation of beamlet deflections (caused by electron suppression filter fields) with increasing voltage in the extraction gap was studied.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑