蜘蛛离子源与引出电源——运行四年后的设计更新
Spider Ion Source and Extraction Power Supplies -- An update of the design after four years of operation
AI总结:
本文基于SPIDER离子源四年运行经验,重新评估ISEPS中偏置电源的设计要求,提出将其从单象限谐振变换器改为四象限运行并将额定输出电压提高一倍。
摘要:
SPIDER是ITER中性束注入器的离子源原型,自2018年起投入运行。该实验包含一套离子源与引出电源(ISEPS)系统,其设计可追溯至2011年。自那时以来,所积累的经验带来了实质性变更,其中最重大的修改是射频电源的完全更换,相关情况已在别处描述。本文详细介绍了运行经验和计算,这些工作促成了对特定电源子集——偏置电源——新要求的定义。偏置电源的功能是滤除与负离子一同引出的电子,在2011年最初的ISEPS设计中为单象限谐振变换器。对于这两台偏置电源,本文所述审查得出的结论是进行实质性重新设计,其中最重要的新规格包括具备四象限运行能力以及额定输出电压提高一倍。
英文摘要:
SPIDER, the ion source prototype for ITER neutral beam injectors, has been in operation since 2018. The experiment includes a system of Ion Source and Extraction Power Supplies (ISEPS), whose design dates back to 2011. Since then the experience gained has led to substantial changes, the most dramatic modification being the complete replacement of the radiofrequency power supply, described elsewhere. This contribution details operating experience and calculations that have led to defining new requirements for a specific subset of power supplies, the bias power supplies. The bias power supplies perform the function of filtering out electrons extracted together with the negative ions and in the original 2011 ISEPS design are single quadrant resonant converters. For the two bias power supplies, the picture resulting from the review described in the paper is a substantial redesign, with the ability to operate in four quadrants and a twofold increase of the rated output voltage the most significant new specifications.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。