负离子源微波干涉仪SPIDER的数值和实验研究
Numerical and experimental investigations of a microwave interferometer for the negative ion source SPIDER
摘要:
聚变堆负离子源运行时,引出栅附近的电子密度和共引出电子是一个关键问题。在等离子体膨胀区域中的过大的电子密度确实可以抑制负离子的产生并且在加速器中引入潜在有害的电子。在为SPIDER升级提出的一套等离子体和光束诊断中,正在探索在100 GHz的外差微波(MW)干涉仪作为测量等离子体提取区域中电子密度的可能性。在天基信息平台中应用这一技术的主要问题是探测微波束穿过源金属壁的可达性差,微波模块应位于真空容器外4米的长距离处。在一个全尺寸的几何形状的数值研究表明,通过等离子体源孔传输的功率是足够的微波模块的灵敏度。然后进行了该装置的实验原理验证。微波系统进行了测试,在一个实验性的全尺寸测试台模仿蜘蛛视口可访问性的限制,包括蜘蛛般的等离子体的存在。第一次测试的结果表明,尽管几何约束,在某些条件下,电子密度测量是可能的。主要问题来自于将单通信号从由mw波束反射产生的伪多径中解耦,这需要信号互相关分析。这些初步测试表明,尽管微波模块之间的距离为4米,并且存在金属壁,但当80毫米直径的端口可用时,等离子体密度测量是可能的。在这方面的贡献,我们讨论了数值模拟,初步的实验测试,并建议设计升级的干涉设置,以提高信号传输。
英文摘要:
The electron density close to the extraction grids and the co-extracted electrons represent a crucial issue when operating negative ion sources for fusion reactors. An excessive electron density in the plasma expansion region can indeed inhibit the negative ion production and introduce potentially harmful electrons in the accelerator. Among the set of plasma and beam diagnostics proposed for SPIDER upgrade, a heterodyne microwave (mw) interferometer at 100 GHz is being explored as a possibility to measure electron density in the plasma extraction region. The major issue in applying this technique in SPIDER is the poor accessibility of the probing microwave beam through the source metal walls and the long distance of 4 m at which mw modules should be located outside the vacuum vessel. Numerical investigations in a full-scale geometry showed that the power transmitted through the plasma source apertures was sufficient for the microwave module sensitivity. An experimental proof-of-principle of the setup was then performed. The microwave system was tested on an experimental full-scale test-bench mimicking SPIDER viewports accessibility constraints, including the presence of a SPIDER-like plasma. The outcome of first tests revealed that, despite the geometrical constraints, in certain conditions, the electron density measurements are possible. The main issue arises from decoupling the one-pass signal from spurious multipaths generated by mw beam reflections, requiring signal cross correlation analysis. These preliminary tests demonstrate that despite the 4 m distance between the mw modules and the presence of metal walls, plasma density measurement is possible when the 80-mm diameter ports are available. In this contribution, we discuss the numerical simulations, the preliminary experimental tests and suggest design upgrades of the interferometric setup to enhance signal transmission.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。