In cardiac CINE, motion-compensated MR reconstruction (MCMR) is an effective approach to address highly undersampled acquisitions by incorporating motion information between frames. In this work, we propose a novel perspective for addressing the MCMR problem and a more integrated and efficient solution to the MCMR field. Contrary to state-of-the-art (SOTA) MCMR methods which break the original problem into two sub-optimization problems, i.e. motion estimation and reconstruction, we formulate this problem as a single entity with one single optimization. Our approach is unique in that the motion estimation is directly driven by the ultimate goal, reconstruction, but not by the canonical motion-warping loss (similarity measurement between motion-warped images and target images). We align the objectives of motion estimation and reconstruction, eliminating the drawbacks of artifacts-affected motion estimation and therefore error-propagated reconstruction. Further, we can deliver high-quality reconstruction and realistic motion without applying any regularization/smoothness loss terms, circumventing the non-trivial weighting factor tuning. We evaluate our method on two datasets: 1) an in-house acquired 2D CINE dataset for the retrospective study and 2) the public OCMR cardiac dataset for the prospective study. The conducted experiments indicate that the proposed MCMR framework can deliver artifact-free motion estimation and high-quality MR images even for imaging accelerations up to 20x, outperforming SOTA non-MCMR and MCMR methods in both qualitative and quantitative evaluation across all experiments. The code is available at https://github.com/JZPeterPan/MCMR-Recon-Driven-Motion.
Cine cardiac MRI reconstruction using a convolutional recurrent network with refinement
Institute for Digital Communications, University of Edinburgh(爱丁堡大学数字通信研究所);Institute of Information Science and Technologies “Alessandro Faedo”, National Research Council of Italy (CNR)(意大利国家研究委员会信息科学与技术研究所(亚历山德罗·法埃多));Department of Information Engineering, University of Pisa(比萨大学信息工程系);Institute for Infrastructure and Environment, University of Edinburgh(爱丁堡大学基础设施与环境研究所);The Alan Turing Institute(阿兰·图灵研究所)
Quality-aware Cine Cardiac MRI Reconstruction and Analysis from Undersampled k-space Data
School of Biomedical Engineering & Imaging Sciences, King’s College London, UK(伦敦国王学院生物医学工程与成像科学学院);Technical University of Munich, Germany(慕尼黑工业大学);Biomedical Image Analysis Group, Imperial College London, UK(帝国理工学院生物医学图像分析组);Department of Adult and Paediatric Cardiology, Guy’s and St Thomas’ NHS Foundation Trust, London, UK(盖伊和圣托马斯国民健康服务信托基金会成人及儿科心脏病科);Coimbra Institute for Biomedical Imaging and Translational Research, University of Coimbra, Portugal(科英布拉大学科英布拉生物医学成像与转化研究学院);Helmholtz Center Munich, Germany(慕尼黑亥姆霍兹中心)
An End-To-End-Trainable Iterative Network Architecture for Accelerated Radial Multi-Coil 2D Cine MR Image Reconstruction
Physikalisch-Technische Bundesanstalt (PTB)(德国联邦物理技术研究院);University of Innsbruck(因斯布鲁克大学);King’s College London(伦敦国王学院);Technical University of Berlin(柏林工业大学)
Personalized 3D Myocardial Infarct Geometry Reconstruction from Cine MRI with Explicit Cardiac Motion Modeling
Department of Biomedical Engineering, National University of Singapore, Singapore(新加坡国立大学生物医学工程系);Department of Computer Science, National University of Singapore, Singapore(新加坡国立大学计算机科学系);Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand(奥克兰大学生物工程研究所);School of Biomedical Engineering and Imaging Sciences, King’s College London, UK(伦敦国王学院生物医学工程与成像科学学校);Department of Medicine, National University of Singapore, Singapore(新加坡国立大学医学系);Department of Cardiology, National University Heart Centre Singapore, Singapore(新加坡国立心脏中心心血管科)
Reconstruction of Cardiac Cine MRI Using Motion-Guided Deformable Alignment and Multi-Resolution Fusion
School of Health Science and Engineering, University of Shanghai for Science and Technology(上海理工大学健康科学与工程学院);ToolSensing Technologies Co., Ltd(拓深科技有限公司);School of Medical Instruments, Shanghai University of Medicine and Health Sciences(上海健康医学院医疗器械学院);Shanghai Key Laboratory of Multidimensional Information Processing, School of Communication & Electronic Engineering, East China Normal University(华东师范大学通信与电子工程学院多维信息处理上海重点实验室)
Personalized 4D Whole Heart Geometry Reconstruction from Cine MRI for Cardiac Digital Twins
Department of Biomedical Engineering, National University of Singapore, Singapore(新加坡国立大学生物医学工程系);School of Data Science, Fudan University, Shanghai, China(复旦大学数据科学学院);Department of Engineering Science, University of Oxford, Oxford, UK(牛津大学工程科学系);Department of Medicine, National University of Singapore, Singapore(新加坡国立大学医学系);Department of Cardiology, National University Heart Centre Singapore, Singapore(新加坡国立心脏中心心内科部)
Gabor Primitives for Accelerated Cardiac Cine MRI Reconstruction
Chair for AI in Healthcare and Medicine, Technical University of Munich (TUM) and TUM University Hospital, Munich, Germany(人工智能在医疗与医学中的chair,慕尼黑技术大学(TUM)和慕尼黑技术大学医院,德国慕尼黑);School of Computation and Information Technology, Technical University of Munich, Munich, Germany(计算与信息科技学院,慕尼黑技术大学,德国慕尼黑);Institute of Machine Learning in Biomedical Imaging, Helmholtz Munich, Neuherberg, Germany(生物医学影像中的机器学习研究所,海德堡慕尼黑,德国纽赫堡);Department of Radiology, Boston Children's Hospital and Harvard Medical School, Boston, USA(放射科,波士顿儿童医院和哈佛医学院,美国波士顿);Munich Center for Machine Learning, Technical University of Munich, Munich, Germany(慕尼黑机器学习中心,慕尼黑技术大学,德国慕尼黑);GE HealthCare, Munich, Germany(通用电气医疗系统,德国慕尼黑);School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom(生物医学工程与成像科学学院,伦敦国王学院,英国伦敦);Department of Computing, Imperial College London, London, United Kingdom(计算学院,伦敦帝国学院,英国伦敦)
本文提出 Gabor 原始要素用于加速心脏 cine MRI 重建,通过调制高斯包络实现灵活频谱支持,提升对光滑结构和锐利边界的表示能力。
Unsupervised Adaptive Neural Network Regularization for Accelerated Radial Cine MRI
Charité - Universitätsmedizin Berlin(夏里特大学医学院);Berlin Institute of Health(柏林健康研究所);Physikalisch-Technische Bundesanstalt (PTB)(德国联邦物理技术研究院);King’s College London(伦敦国王学院);Technical University of Berlin(柏林工业大学);University of Innsbruck(因斯布鲁克大学)
An Unsupervised Deep Learning Method for Multi-coil Cine MRI
Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences(中国科学院深圳先进技术研究院保罗·C·劳特伯生物医学成像研究中心);Research Center for Medical AI, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences(中国科学院深圳先进技术研究院医学人工智能研究中心);Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences(中国科学院大学深圳先进技术学院);The State University of New York, Buffalo(纽约州立大学布法罗分校)
Density Compensated Unrolled Networks for Non-Cartesian MRI Reconstruction
CEA/NeuroSpin(法国原子能与替代能源委员会神经自旋中心);CEA(法国原子能与替代能源委员会);CNRS(法国国家科学研究中心);Université Paris-Saclay(巴黎萨克雷大学);Université Paris Diderot(巴黎第七大学);Sorbonne Paris Cité(索邦巴黎西岱大学);Inria Saclay Ile-de-France(法国国家信息与自动化研究所萨克雷-法兰西岛分院)
Subspace Implicit Neural Representations for Real-Time Cardiac Cine MR Imaging
Technical University of Munich(慕尼黑工业大学);Helmholtz Munich(亥姆霍兹慕尼黑中心);University of Tübingen(蒂宾根大学);University of Michigan(密歇根大学);Pontificia Universidad Católica de Chile(智利天主教大学);King’s College London(伦敦国王学院);Imperial College London(帝国理工学院)
Attention Incorporated Network for Sharing Low-rank, Image and K-space Information during MR Image Reconstruction to Achieve Single Breath-hold Cardiac Cine Imaging
University of Tuebingen(蒂宾根大学);Technical University of Munich(慕尼黑工业大学);Imperial College London(伦敦帝国学院);Stanford University(斯坦福大学);Klinikum Rechts der Isar, Technical University of Munich(慕尼黑工业大学右岸医院)
Structure-aware Unsupervised Tagged-to-Cine MRI Synthesis with Self Disentanglement
Massachusetts General Hospital(麻省总医院);Harvard Medical School(哈佛医学院);Johns Hopkins University(约翰斯·霍普金斯大学);University of Maryland School of Dentistry(马里兰大学牙医学院)
DeepRecon: Joint 2D Cardiac Segmentation and 3D Volume Reconstruction via A Structure-Specific Generative Method
Rutgers University(罗格斯大学);SenseBrain Research(SenseBrain研究院);University of Arkansas for Medical Sciences(阿肯色大学医学院);Lund University(隆德大学);New York University(纽约大学)
Dual-cycle Constrained Bijective VAE-GAN For Tagged-to-Cine Magnetic Resonance Image Synthesis
Massachusetts General Hospital(麻省总医院);Harvard Medical School(哈佛医学院);Johns Hopkins University(约翰斯·霍普金斯大学);University of Maryland School of Dentistry(马里兰大学牙科学院)
Time-resolved aortic 3D shape reconstruction from a limited number of cine 2D MRI slices
Institute for Biomedical Engineering, University Zurich and ETH Zurich(苏黎世大学与苏黎世联邦理工学院生物医学工程研究所);Department of Cardiology, University Heart Center, University Hospital Zurich, University of Zurich(苏黎世大学心脏中心苏黎世大学医院心脏病科);Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich(苏黎世大学苏黎世大学医院诊断与治疗放射科)
Real-time cardiac cine MRI -- A comparison of a diffusion probabilistic model with alternative state-of-the-art image reconstruction techniques for undersampled spiral acquisitions
Spatio-Temporal Deep Learning-Based Undersampling Artefact Reduction for 2D Radial Cine MRI with Limited Data
Charité - Universitätsmedizin Berlin(柏林夏里特医学院);Berlin Institute of Health(柏林健康研究所);Physikalisch-Technische Bundesanstalt (PTB)(德国联邦物理技术研究院(PTB));King’s College London(伦敦国王学院)
Attention-aware non-rigid image registration for accelerated MR imaging
University Hospital of Tuebingen(蒂宾根大学医院);Klinikum Rechts der Isar(右岸医院(慕尼黑工业大学附属));Technical University of Munich(慕尼黑工业大学);School of Computation, Information and Technology, Technical University of Munich(慕尼黑工业大学计算、信息与技术学院);Imperial College London(伦敦帝国学院)
Accelerating Cardiac MRI Reconstruction with CMRatt: An Attention-Driven Approach
ML-Labs Dublin City University(都柏林城市大学ML实验室);Insight SFI Research Centre for Data Analytics Dublin City University(都柏林城市大学Insight SFI数据分析研究中心);School of Medicine University College Dublin(都柏林大学学院医学院)
DMCVR: Morphology-Guided Diffusion Model for 3D Cardiac Volume Reconstruction
Rutgers University(罗格斯大学);FocusAI Inc.(FocusAI公司);Walmart Global Tech(沃尔玛全球技术公司);New York University(纽约大学);Sichuan University West China Hospital(四川大学华西医院)