Spatio-Temporal Deep Learning-Based Undersampling Artefact Reduction for 2D Radial Cine MRI with Limited Data
Charité - Universitätsmedizin Berlin(柏林夏里特医学院);Berlin Institute of Health(柏林健康研究所);Physikalisch-Technische Bundesanstalt (PTB)(德国联邦物理技术研究院(PTB));King’s College London(伦敦国王学院)
Andreas Kofler, Marc Dewey, Tobias Schaeffter, Christian Wald, Christoph Kolbitsch
备注:
To be published in IEEE Transactions on Medical Imaging
In this work we reduce undersampling artefacts in two-dimensional ($2D$) golden-angle radial cine cardiac MRI by applying a modified version of the U-net. We train the network on $2D$ spatio-temporal slices which are previously extracted from the image sequences. We compare our approach to two $2D$ and a $3D$ Deep Learning-based post processing methods and to three iterative reconstruction methods for dynamic cardiac MRI. Our method outperforms the $2D$ spatially trained U-net and the $2D$ spatio-temporal U-net. Compared to the $3D$ spatio-temporal U-net, our method delivers comparable results, but with shorter training times and less training data. Compared to the Compressed Sensing-based methods $kt$-FOCUSS and a total variation regularised reconstruction approach, our method improves image quality with respect to all reported metrics. Further, it achieves competitive results when compared to an iterative reconstruction method based on adaptive regularization with Dictionary Learning and total variation, while only requiring a small fraction of the computational time. A persistent homology analysis demonstrates that the data manifold of the spatio-temporal domain has a lower complexity than the spatial domain and therefore, the learning of a projection-like mapping is facilitated. Even when trained on only one single subject without data-augmentation, our approach yields results which are similar to the ones obtained on a large training dataset. This makes the method particularly suitable for training a network on limited training data. Finally, in contrast to the spatial $2D$ U-net, our proposed method is shown to be naturally robust with respect to image rotation in image space and almost achieves rotation-equivariance where neither data-augmentation nor a particular network design are required.
School of Biomedical Engineering & Imaging Sciences, King’s College London, UK(伦敦国王学院生物医学工程与成像科学学院);Technical University of Munich, Germany(慕尼黑工业大学);Biomedical Image Analysis Group, Imperial College London, UK(帝国理工学院生物医学图像分析组);Department of Adult and Paediatric Cardiology, Guy’s and St Thomas’ NHS Foundation Trust, London, UK(盖伊和圣托马斯国民健康服务信托基金会成人及儿科心脏病科);Coimbra Institute for Biomedical Imaging and Translational Research, University of Coimbra, Portugal(科英布拉大学科英布拉生物医学成像与转化研究学院);Helmholtz Center Munich, Germany(慕尼黑亥姆霍兹中心)
Cine cardiac MRI is routinely acquired for the assessment of cardiac health, but the imaging process is slow and typically requires several breath-holds to acquire sufficient k-space profiles to ensure good image quality. Several undersampling-based reconstruction techniques have been proposed during the last decades to speed up cine cardiac MRI acquisition. However, the undersampling factor is commonly fixed to conservative values before acquisition to ensure diagnostic image quality, potentially leading to unnecessarily long scan times. In this paper, we propose an end-to-end quality-aware c…
Guy’s and St Thomas’ Hospital NHS Foundation Trust(盖伊和圣托马斯医院NHS基金会信托);King’s College London(伦敦国王学院);Imperial College London(帝国理工学院)
In fully sampled cardiac MR (CMR) acquisitions, motion can lead to corruption of k-space lines, which can result in artefacts in the reconstructed images. In this paper, we propose a method to automatically detect and correct motion-related artefacts in CMR acquisitions during reconstruction from k-space data. Our correction method is inspired by work on undersampled CMR reconstruction, and uses deep learning to optimize a data-consistency term for under-sampled k-space reconstruction. Our main methodological contribution is the addition of a detection network to classify motion-corrupted k-sp…
Cine cardiac MRI reconstruction using a convolutional recurrent network with refinement
Institute for Digital Communications, University of Edinburgh(爱丁堡大学数字通信研究所);Institute of Information Science and Technologies “Alessandro Faedo”, National Research Council of Italy (CNR)(意大利国家研究委员会信息科学与技术研究所(亚历山德罗·法埃多));Department of Information Engineering, University of Pisa(比萨大学信息工程系);Institute for Infrastructure and Environment, University of Edinburgh(爱丁堡大学基础设施与环境研究所);The Alan Turing Institute(阿兰·图灵研究所)
Istanbul Technical University(伊斯坦布尔理工大学);King’s College London(伦敦国王学院)
Segmenting anatomical structures in medical images has been successfully addressed with deep learning methods for a range of applications. However, this success is heavily dependent on the quality of the image that is being segmented. A commonly neglected point in the medical image analysis community is the vast amount of clinical images that have severe image artefacts due to organ motion, movement of the patient and/or image acquisition related issues. In this paper, we discuss the implications of image motion artefacts on cardiac MR segmentation and compare a variety of approaches for joint…
Otto von Guericke University Magdeburg(马格德堡奥托·冯·格里克大学)
MRI is an inherently slow process, which leads to long scan time for high-resolution imaging. The speed of acquisition can be increased by ignoring parts of the data (undersampling). Consequently, this leads to the degradation of image quality, such as loss of resolution or introduction of image artefacts. This work aims to reconstruct highly undersampled Cartesian or radial MR acquisitions, with better resolution and with less to no artefact compared to conventional techniques like compressed sensing. In recent times, deep learning has emerged as a very important area of research and has show…
Attention Incorporated Network for Sharing Low-rank, Image and K-space Information during MR Image Reconstruction to Achieve Single Breath-hold Cardiac Cine Imaging
University of Tuebingen(蒂宾根大学);Technical University of Munich(慕尼黑工业大学);Imperial College London(伦敦帝国学院);Stanford University(斯坦福大学);Klinikum Rechts der Isar, Technical University of Munich(慕尼黑工业大学右岸医院)
Deep Learning Assisted Outer Volume Removal for Highly-Accelerated Real-Time Dynamic MRI
Department of Electrical and Computer Engineering, University of Minnesota(电气与计算机工程系,明尼苏达大学);Center for Magnetic Resonance Research, University of Minnesota(磁共振研究中心,明尼苏达大学);Department of Imaging Physics, Delft University of Technology(成像物理系,代尔夫特理工大学);HollandPTC, Delft, the Netherlands(HollandPTC,代尔夫特,荷兰)
Cardiovascular MRI (CMR) is a non-invasive imaging modality that provides excellent soft-tissue contrast without the use of ionizing radiation. Physiological motions and limited speed of MRI data acquisition necessitate development of accelerated methods, which typically rely on undersampling. Recovering diagnostic quality CMR images from highly undersampled data has been an active area of research. Recently, several data acquisition and processing methods have been proposed to accelerate CMR. The availability of data to objectively evaluate and compare different reconstruction methods could e…
Low Dose Computed Tomography suffers from a high amount of noise and/or undersampling artefacts in the reconstructed image. In the current article, a Deep Learning technique is exploited as a regularization term for the iterative reconstruction method SIRT. While SIRT minimizes the error in the sinogram space, the proposed regularization model additionally steers intermediate SIRT reconstructions towards the desired output. Extensive evaluations demonstrate the superior outcomes of the proposed method compared to the state of the art techniques. Comparing the forward projection of the reconstr…
DUN-SRE: Deep Unrolling Network with Spatiotemporal Rotation Equivariance for Dynamic MRI Reconstruction
University of Nottingham Ningbo China(诺丁汉大学宁波校区);Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences(深圳先进技术研究院);School of Mathematics and Statistics, Xi’an Jiaotong University(西安交通大学数学与统计学院)
Imperial College London(帝国理工学院);Royal Brompton Hospital(皇家布朗普顿医院);Sun Yat-sen University(中山大学);Beihang University(北京航空航天大学);University of the Basque Country UPV/EHU(巴斯克大学(UPV/EHU));TECNALIA(泰克纳利亚研究中心);Shenzhen Second People’s Hospital(深圳市第二人民医院);The First Affiliated Hospital of Shenzhen University Health Science Center(深圳大学医学部第一附属医院)
Magnetic resonance imaging (MRI) is an important non-invasive clinical tool that can produce high-resolution and reproducible images. However, a long scanning time is required for high-quality MR images, which leads to exhaustion and discomfort of patients, inducing more artefacts due to voluntary movements of the patients and involuntary physiological movements. To accelerate the scanning process, methods by k-space undersampling and deep learning based reconstruction have been popularised. This work introduced SwinMR, a novel Swin transformer based method for fast MRI reconstruction. The who…
Accelerating Cardiac MRI Reconstruction with CMRatt: An Attention-Driven Approach
ML-Labs Dublin City University(都柏林城市大学ML实验室);Insight SFI Research Centre for Data Analytics Dublin City University(都柏林城市大学Insight SFI数据分析研究中心);School of Medicine University College Dublin(都柏林大学学院医学院)
RSFR: A Coarse-to-Fine Reconstruction Framework for Diffusion Tensor Cardiac MRI with Semantic-Aware Refinement
Imperial College London(帝国理工学院伦敦分校);National Heart and Lung Institute(国家心肺研究所);Cardiovascular Research Centre(心血管研究中心);Royal Brompton Hospital(皇家布里蒙特医院);School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University(中山大学深圳校区生物医学工程学院);Robotics and Autonomous Systems Thrust & Data Science and Analytics Thrust, HKUST (GZ)(香港科技大学(广州)机器人与自主系统 thrust 及数据科学与分析 thrust);Yau Mathematical Sciences Centre, Tsinghua University(清华大学姚数学科学中心);Department of Applied Mathematics and Theoretical Physics, University of Cambridge(剑桥大学应用数学与理论物理系);School of Biomedical Engineering and Imaging Sciences, King’s College London(伦敦国王学院生物医学工程与影像科学学院)
Charité - Universitätsmedizin Berlin(柏林夏里特医学院);University of Innsbruck(因斯布鲁克大学);Physikalisch-Technische Bundesanstalt (PTB)(德国联邦物理技术研究院);Technical University of Berlin(柏林工业大学);German Cancer Research Center(德国癌症研究中心)
In this paper we present a generalized Deep Learning-based approach for solving ill-posed large-scale inverse problems occuring in medical image reconstruction. Recently, Deep Learning methods using iterative neural networks and cascaded neural networks have been reported to achieve state-of-the-art results with respect to various quantitative quality measures as PSNR, NRMSE and SSIM across different imaging modalities. However, the fact that these approaches employ the forward and adjoint operators repeatedly in the network architecture requires the network to process the whole images or volu…
Otto von Guericke University Magdeburg(马格德堡奥托·冯·格里克大学);Human Technopole(人类技术园);German Centre for Neurodegenerative Disease(德国神经退行性疾病中心);Centre for Behavioural Brain Sciences(行为脑科学中心)
Computed tomography and magnetic resonance imaging are two widely used clinical imaging modalities for non-invasive diagnosis. However, both of these modalities come with certain problems. CT uses harmful ionising radiation, and MRI suffers from slow acquisition speed. Both problems can be tackled by undersampling, such as sparse sampling. However, such undersampled data leads to lower resolution and introduces artefacts. Several techniques, including deep learning based methods, have been proposed to reconstruct such data. However, the undersampled reconstruction problem for these two modalit…
Imperial College London(伦敦帝国理工学院);Royal Brompton Hospital(皇家布朗普顿医院);Yantai University(烟台大学);University of Cambridge(剑桥大学);Beijing Institute of Technology(北京理工大学)
Magnetic Resonance Imaging (MRI) is a vital component of medical imaging. When compared to other image modalities, it has advantages such as the absence of radiation, superior soft tissue contrast, and complementary multiple sequence information. However, one drawback of MRI is its comparatively slow scanning and reconstruction compared to other image modalities, limiting its usage in some clinical applications when imaging time is critical. Traditional compressive sensing based MRI (CS-MRI) reconstruction can speed up MRI acquisition, but suffers from a long iterative process and noise-induce…