Realistic 3D printed imaging tumor phantoms for validation of image processing algorithms
Sepideh Hatamikia, Ingo Gulyas, Wolfgang Birkfellner, Gernot Kronreif, Alexander Unger, Gunpreet Oberoi, Andrea Lorenz, Ewald Unger, Joachim Kettenbach, Michael… 展开作者
Sepideh Hatamikia, Ingo Gulyas, Wolfgang Birkfellner, Gernot Kronreif, Alexander Unger, Gunpreet Oberoi, Andrea Lorenz, Ewald Unger, Joachim Kettenbach, Michael Figl, Janina Patsch, Andreas Strassl, Dietmar Georg, Andreas Renner
Medical imaging phantoms are widely used for validation and verification of imaging systems and algorithms in surgical guidance and radiation oncology procedures. Especially, for the performance evaluation of new algorithms in the field of medical imaging, manufactured phantoms need to replicate specific properties of the human body, e.g., tissue morphology and radiological properties. Additive manufacturing (AM) technology provides an inexpensive opportunity for accurate anatomical replication with customization capabilities. In this study, we proposed a simple and cheap protocol to manufacture realistic tumor phantoms based on the filament 3D printing technology. Tumor phantoms with both homogenous and heterogenous radiodensity were fabricated. The radiodensity similarity between the printed tumor models and real tumor data from CT images of lung cancer patients was evaluated. Additionally, it was investigated whether a heterogeneity in the 3D printed tumor phantoms as observed in the tumor patient data had an influence on the validation of image registration algorithms. A density range between -217 to 226 HUs was achieved for 3D printed phantoms; this range of radiation attenuation is also observed in the human lung tumor tissue. The resulted HU range could serve as a lookup-table for researchers and phantom manufactures to create realistic CT tumor phantoms with the desired range of radiodensities. The 3D printed tumor phantoms also precisely replicated real lung tumor patient data regarding morphology and could also include life-like heterogeneity of the radiodensity inside the tumor models. An influence of the heterogeneity on accuracy and robustness of the image registration algorithms was not found.
Purpose: In this study, we present the creation of an anthropomorphic, head and neck, nuclear medicine phantom and its characterization for the validation of a Monte Carlo, SPECT image based, Iodine-131 RPT dosimetry workflow. Methods: 3D printing techniques were used to create the anthropomorphic phantom from a patient CT dataset. Three Iodine-131 SPECT/CT imaging studies were performed using a homogeneous, Jaszczak, and an anthropomorphic phantom to quantify the SPECT images. The impact of collimator detector response (CDR) modeling and volume-based partial volume corrections (PVC) upon the …
Recently we have developed an algorithm for reconstructing volumetric images and extracting 3D tumor motion information from a single x-ray projection. We have demonstrated its feasibility using a digital respiratory phantom with regular breathing patterns. In this work, we present a detailed description and a comprehensive evaluation of the improved algorithm. The algorithm was improved by incorporating respiratory motion prediction. The accuracy and efficiency were then evaluated on 1) a digital respiratory phantom, 2) a physical respiratory phantom, and 3) five lung cancer patients. These e…
Recently, 3D printing has been widely used to fabricate medical imaging phantoms. So far, various rigid 3D printable materials have been investigated for their radiological properties and efficiency in imaging phantom fabrication. However, flexible, soft tissue materials are also needed for imaging phantoms, which are used in various scenarios, such as anatomical deformations to improve dynamic treatments and various needle-based surgeries and training. Recently, various silicone additive manufacturing technologies have been used to produce anatomical models based on extrusion techniques that …
Fluorescence molecular tomography (FMT) has potential of providing high contrast images for breast tumor detection. Computational phantom provides a convenient way to a wide variety of fluorophore distribution configurations in patients and perform comprehensive evaluation of the imaging systems and methods for FMT. In this study, a digital breast phantom was used to compare the performance of a novel sparsity-based reconstruction method and Tikhonov regularization method for resolving tumors with different amount of separation. The results showed that the proposed sparse reconstruction method…
Purpose: 4D CBCT is a beneficial tool for the treatment of movable tumors, because it can help us to understand where the tumors are actually located and have a precise treatment plan. However, there is a limitation that general CBCT images cannot perfectly help the sophisticated registration. On the other hand, SymmetryTM 4D IGRT system of Elekta can offer the 4D CBCT registration option. In this study, we intend to evaluate the usefulness of SymmetryTM. Method and Materials: Planning CT images of the CIRS moving lung phantom were acquired from 4D MDCT. And they are sorted as 10 phases from 0…
Hyperthermia has been in use for many years; as a potential alternative modality for cancer treatment. In this paper, an experimental investigation of microwave assisted thermal heating (MWATH) of tissue phantom using a domestic microwave oven has been reported. Computer simulations using finite element method based tools was also carried out to support the experimental observations and probe insight on the thermal transport aspects deep within the tissue phantom. A good agreement between predicted and measured temperature were achieved. Furthermore, experiments were conducted to investigate t…
The effects of gold nanoparticles in 125I brachytherapy dose enhancement on choroidal Melanoma are examined using the Monte Carlo simulation technique. Usually, Monte Carlo ophthalmic brachytherapy dosimetry is performed in a water phantom. However, here, the compositions of human eye have been considered instead of water. Both human eye and water phantoms have been simulated with MCNP5 code. These simulations were performed for a fully-loaded 16 mm COMS eye plaque containing 13 125I seeds. The dose delivered to the tumor and healthy tissues have been calculated in both phantoms, with and with…
The aim of the present Monte Carlo study is to evaluate the variation of energy deposition in healthy tissues in the human eye which is irradiated by brachytherapy sources in comparison with the resultant dose increase in the gold nanoparticle(GNP)-loaded choroidal melanoma. The effects of these nanoparticles on normal tissues are compared between 103Pd and 125I as two ophthalmic brachytherapy sources. Dose distribution in the tumor and healthy tissues have been taken into account for both mentioned brachytherapy sources. Also, in a certain point of the eye, the ratio of the absorbed dose by t…
Purpose: To develop an algorithm for real-time volumetric image reconstruction and 3D tumor localization based on a single x-ray projection image for lung cancer radiotherapy. Methods: Given a set of volumetric images of a patient at N breathing phases as the training data, we perform deformable image registration between a reference phase and the other N-1 phases, resulting in N-1 deformation vector fields (DVFs). These DVFs can be represented efficiently by a few eigenvectors and coefficients obtained from principal component analysis (PCA). By varying the PCA coefficients, we can generate n…
Ultrasound computed tomography (USCT) is an emerging imaging modality for breast imaging that can produce quantitative images that depict the acoustic properties of tissues. Computer-simulation studies, also known as virtual imaging trials, provide researchers with an economical and convenient route to systematically explore imaging system designs and image reconstruction methods. When simulating an imaging technology intended for clinical use, it is essential to employ realistic numerical phantoms that can facilitate the objective, or task-based, assessment of image quality. Moreover, when co…
Mie scattering due to tissue structures in the terahertz regime: Experimental and Monte Carlo verification using diffused polarimetric imaging in highly attenuating tissue phantoms
Precise quantitative delineation of tumor hypoxia is essential in radiation therapy treatment planning to improve the treatment efficacy by targeting hypoxic sub-volumes. We developed a combined imaging system of positron emission tomography (PET) and electron para-magnetic resonance imaging (EPRI) of molecular oxygen to investigate the accuracy of PET imaging in assessing tumor hypoxia. The PET/EPRI combined imaging system aims to use EPRI to precisely measure the oxygen partial pressure in tissues. This will evaluate the validity of PET hypoxic tumor imaging by (near) simultaneously acquired…
Purpose: Implanted fiducial markers are often used in radiotherapy to facilitate accurate visualization and localization of tumors. Typically, such markers are used to aid daily patient positioning and to verify the target's position during treatment. This work introduces a novel, automated method for identifying fiducial markers in planar x-ray imaging. Methods: In brief, the method consists of automated filtration and reconstruction steps that generate 3D templates of marker positions. The normalized cross-correlation was the used to identify fiducial markers in projection images. To quantif…
Hôpital Erasme(埃拉斯姆医院);Université libre de Bruxelles(布鲁塞尔自由大学);Center for Microscopy and Molecular Imaging(显微与分子成像中心)
Diffuse gliomas are highly infiltrative tumors whose early diagnosis and follow-up usually rely on magnetic resonance imaging (MRI). However, the limited sensitivity of this technique makes it impossible to directly assess the extent of the glioma cell invasion, leading to sub-optimal treatment planing. Reaction-diffusion growth models have been proposed for decades to extrapolate glioma cell infiltration beyond margins visible on MRI and predict its spatial-temporal evolution. These models nevertheless require an initial condition, that is the tumor cell density values at every location of th…
Objective: Alterations of Young's modulus (YM) and Poisson's ratio (PR) in biological tissues are often early indicators of the onset of pathological conditions. Knowledge of these parameters has been proven to be of great clinical significance for the diagnosis, prognosis and treatment of cancers. Currently, however, there are no non-invasive modalities that can be used to image and quantify these parameters in vivo without assuming incompressibility of the tissue, an assumption that is rarely justified in human tissues. Methods: In this paper, we develop a new method to simultaneously recons…
Quantitative accuracy and thus diagnostic precision in Emission Tomography is impaired by the inherent random characteristics of the data acquisition leading to statistical image noise. Edge preserving spatial variation regularized iterative image reconstruction approaches require case-specific control parameter adaptation for optimized contrast-vs-noise tradeoff. For MLEM reconstruction, we propose and evaluate iRDF which automatically adapts RDP edge preservation parameters according to local image noise and PET data characteristics. In order to distinguish between clustered noise spots and …
Intrafraction motion can play a pivotal role in the success of abdominal and thoracic radiation therapy. Hybrid magnetic resonance-guided radiotherapy systems have the potential to control for intrafraction motion. Recently, we introduced an MRI sequence capable of acquiring real-time cine imaging in two orthogonal planes (SOPI). We extend SOPI here to permit dynamic updating of slice positions in one plane while keeping the other plane position fixed. In this implementation, cine images from the static plane are used for motion monitoring and as image navigators to sort stepped images in the …
Direct correlation of intravoxel incoherent motion imaging based on implicit neural representations and histopathology in pediatric Wilms tumors: can it differentiate between subtypes?
University Medical Center Utrecht(乌得勒支大学医学中心);Princess Máxima Center for Pediatric Oncology(公主玛西玛儿童肿瘤中心);Wilhelmina Children’s Hospital, Utrecht University(乌得勒支大学威廉明娜儿童医院);University of Twente(特文特大学)
Intraoperative Gamma Probe (IPG) remains the current gold standard modality for sentinel lymph node identification and tumor removal in cancer patients. However, even alongside the optical dyes they do not meet with <5% false negative rates (FNR) requirement, a key metric suggested by the American Society of Clinical Oncology (ASCO). We are aiming to reduce FNR by using time of flight (TOF) PET detector technology in the limited angle geometry system by using only two detector buckets in coincidence, where one small-area detector is placed above the patient and the other with larger detection-…
Ultra-high frequency ultrasound imaging and quantification of microvascular flow in xenograft renal cell carcinoma in an avian chorioallantoic membrane model
Objective: Dynamic cone-beam CT (CBCT) imaging is highly desired in image-guided radiation therapy to provide volumetric images with high spatial and temporal resolutions to enable applications including tumor motion tracking/prediction and intra-delivery dose calculation/accumulation. However, the dynamic CBCT reconstruction is a substantially challenging spatiotemporal inverse problem, due to the extremely limited projection sample available for each CBCT reconstruction (one projection for one CBCT volume). Approach: We developed a simultaneous spatial and temporal implicit neural representa…
Beam quality optimization in mammography traditionally considers detection of a target obscured by quantum noise on a homogenous background. It can be argued that this scheme does not correspond well to the clinical imaging task because real mammographic images contain a complex superposition of anatomical structures, resulting in anatomical noise that may dominate over quantum noise. Using a newly developed spectral mammography system, we measured the correlation and magnitude of the anatomical noise in a set of mammograms. The results from these measurements were used as input to an observer…
We present a technique for continuous generation of volumetric images during SBRT using periodic kV imaging and an external respiratory surrogate signal to drive a patient-specific PCA motion model. Using the on-board imager, kV radiographs are acquired every 3 seconds and used to fit the parameters of a motion model so that it matches observed changes in internal patient anatomy. A multi-dimensional correlation model is established between the motion model parameters and the external surrogate position and velocity, enabling volumetric image reconstruction between kV imaging time points. Perf…
Speed-of-sound has been shown as a potential biomarker for breast cancer imaging, successfully differentiating malignant tumors from benign ones. Speed-of-sound images can be reconstructed from time-of-flight measurements from ultrasound images acquired using conventional handheld ultrasound transducers. Variational Networks (VN) have recently been shown to be a potential learning-based approach for optimizing inverse problems in image reconstruction. Despite earlier promising results, these methods however do not generalize well from simulated to acquired data, due to the domain shift. In thi…
In this paper, we present a new method to generate an instantaneous volumetric image using a single x-ray projection. To fully extract motion information hidden in projection images, we partitioned a projection image into small patches. We utilized a sparse learning method to automatically select patches that have a high correlation with principal component analysis (PCA) coefficients of a lung motion model. A model that maps the patch intensity to the PCA coefficients is built along with the patch selection process. Based on this model, a measured projection can be used to predict the PCA coe…
On Real-time Image Reconstruction with Neural Networks for MRI-guided Radiotherapy
Faculty of Medicine and Health, The University of Sydney(澳大利亚悉尼大学医学与健康学院);Ingham Institute for Applied Medical Research(英厄姆应用医学研究所);A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital(麻省总医院A.A.马蒂诺斯生物医学成像中心)
Physics-Constrained Diffusion Reconstruction with Posterior Correction for Quantitative and Fast PET Imaging
Beijing Normal University(北京师范大学);Beijing Friendship Hospital, Capital Medical University(首都医科大学北京友谊医院);The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China(中国科学技术大学生命科学与医学部附属第一医院);Jiangnan University(江南大学);University of Melbourne(墨尔本大学)
Four-dimensional computed tomography (4DCT) has been widely used in cancer radiotherapy for accurate target delineation and motion measurement for tumors in thorax and upper abdomen areas. However, 4DCT simulation is associated with much higher imaging dose than conventional CT simulation, which is a major concern in its clinical application. Conventionally, each phase of 4DCT is reconstructed independently using the filtered backprojection (FBP) algorithm. The basic idea of our new algorithm is that, by utilizing the common information among different phases, the input information required to…
Precise patient positioning and thus precise positioning of the planning target volume (PTV) is a prerequisite for effective treatment in percutaneous radiation therapy. Conventional imaging modalities used to ensure exact positioning for treatment typically involve additional radiation exposure of the patient. A different approach to patient alignment without additional exposure is provided by optical 3D surface scanning and registration systems. We investigated two systems Catalyst and AlignRT, which allowed us to generate and validate surface images of 50 patients undergoing irradiation on …
University of Waterloo(滑铁卢大学);University of Toronto(多伦多大学);Sunnybrook Research Institute(森尼布鲁克研究所)
Diffusion weighted magnetic resonance imaging (DW-MR) is a powerful tool in imaging-based prostate cancer screening and detection. Endorectal coils are commonly used in DW-MR imaging to improve the signal-to-noise ratio (SNR) of the acquisition, at the expense of significant intensity inhomogeneities (bias field) that worsens as we move away from the endorectal coil. The presence of bias field can have a significant negative impact on the accuracy of different image analysis tasks, as well as prostate tumor localization, thus leading to increased inter- and intra-observer variability. Retrospe…