Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c
B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, M. Alhusseini, J. Alison, J. P. Figueiredo de sa Sousa de Almeida, P. G. Dias de Almeida, A.… 展开作者
B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, M. Alhusseini, J. Alison, J. P. Figueiredo de sa Sousa de Almeida, P. G. Dias de Almeida, A. Alpana, M. Alyari, I. Andreev, U. Aras, P. Aspell, I. O. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, S. Banerjee, P. DeBarbaro, P. Bargassa, D. Barney, F. Beaudette, F. Beaujean, E. Becheva, A. Becker, P. Behera, A. Belloni, T. Bergauer, M. El Berni, M. Besancon, S. Bhattacharya, S. Bhattacharya, D. Bhowmik, B. Bilki, S. Bilokin, G. C. Blazey, F. Blekman, P. Bloch, A. Bodek, M. Bonanomi, J. Bonis, A. Bonnemaison, S. Bonomally, J. Borg, F. Bouyjou, N. Bower, D. Braga, L. Brennan, E. Brianne, E. Brondolin, P. Bryant, E. Buhmann, P. Buhmann, A. Butler-Nalin, O. Bychkova, S. Callier, D. Calvet, K. Canderan, K. Cankocak, X. Cao, A. Cappati, B. Caraway, S. Caregari, C. Carty, A. Cauchois, L. Ceard, D. S. Cerci, S. Cerci, G. Cerminara, M. Chadeeva, N. Charitonidis, R. Chatterjee, J. A. Chen, Y. M. Chen, H. J. Cheng, K. Y. Cheng, H. Cheung, D. Chokheli, M. Cipriani, D. Čoko, F. Couderc, E. Cuba, M. Danilov, D. Dannheim, W. Daoud, I. Das, P. Dauncey, G. Davies, O. Davignon, E. Day, P. Debbins, M. M. Defranchis, E. Delagnes, Z. Demiragli, U. Demirbas, G. Derylo, D. Diaz, L. Diehl, P. Dinaucourt, G. G. Dincer, J. Dittmann, M. Dragicevic, S. Dugad, F. Dulucq, I. Dumanoglu, M. Dünser, S. Dutta, V. Dutta, T. K. Edberg, F. Elias, L. Emberger, S. C. Eno, Yu. Ershov, S. Extier, F. Fahim, C. Fallon, K. Sarbandi Fard, G. Fedi, L. Ferragina, L. Forthomme, E. Frahm, G. Franzoni, J. Freeman, T. French, K. Gadow, P. Gandhi, S. Ganjour, X. Gao, M. T. Ramos Garcia, A. Garcia-Bellido, E. Garutti, F. Gastaldi, D. Gastler, Z. Gecse, A. Germer, H. Gerwig, O. Gevin, S. Ghosh, A. Gilbert, W. Gilbert, K. Gill, C. Gingu, S. Gninenko, A. Golunov, I. Golutvin, B. Gonultas, N. Gorbounov, P. Göttlicher, L. Gouskos, C. Graf, A. B. Gray, C. Grieco, S. Gr\"önroos, Y. Gu, F. Guilloux, E. Gurpinar Guler, Y. Guler, E. Gülmez, J. Guo, H. Gutti, A. Hakimi, M. Hammer, O. Hartbrich, H. M. Hassanshahi, K. Hatakeyama, E. Hazen, A. Heering, V. Hegde, U. Heintz, D. Heuchel, N. Hinton, J. Hirschauer, J. Hoff, W. S. Hou, X. Hou, H. Hua, S. Huck, A. Hussain, J. Incandela, A. Irles, A. Irshad, C. Isik, S. Jain, J. Jaroslavceva, H. R. Jheng, U. Joshi, K. Kaadze, V. Kachanov, L. Kalipoliti, A. Kaminskiy, A. R. Kanuganti, Y. W. Kao, A. Kapoor, O. Kara, A. Karneyeu, O. Kałuzińska, M. Kaya, O. Kaya, Y. Kazhykharim, F. A. Khan, A. Khukhunaishvili, J. Kieseler, M. Kilpatrick, S. Kim, K. Koetz, T. Kolberg, M. Komm, O. K. Köseyan, V. Kraus, M. Krawczyk, K. Kristiansen, A. Kristić, M. Krohn, B. Kronheim, K. Krüger, S. Kulis, M. Kumar, S. Kunori, C. M. Kuo, V. Kuryatkov, J. Kvasnicka, S. Kyre, Y. Lai, K. Lamichhane, G. Landsberg, C. Lange, J. Langford, S. Laurien, M. Y. Lee, S. W. Lee, A. G. Stahl Leiton, A. Levin, A. Li, J. H. Li, Y. Y. Li, Z. Liang, H. Liao, Z. Lin, D. Lincoln, L. Linssen, R. Lipton, G. Liu, Y. Liu, A. Lobanov, V. Lohezic, D. Lomidze, R. S. Lu, S. Lu, M. Lupi, I. Lysova, A. -M. Magnan, F. Magniette, A. Mahjoub, S. Martens, M. Matysek, B. Meier, A. Malakhov, S. Mallios, I. Mandjavize, M. Mannelli, J. Mans, A. Marchioro, A. Martelli, G. Martinez, P. Masterson, M. Matthewman, S. N. Mayekar, A. David, S. Coco, B. Meng, A . Menkel, A. Mestvirishvili, G. Milella, I. Mirza, S. Moccia, G. B. Mohanty, F. Monti, F. W. Moortgat, I. Morrissey, J. Motta, S. Murthy, J. Musić, Y. Musienko, S. Nabili, M. Nguyen, A. Nikitenko, D. Noonan, D. Noonan, M. Noy, K. Nurdan, M. Wulansatiti Nursanto, C. Ochando, N. Odell, H. Okawa, Y. Onel, W. Ortez, J. Ozegović, S. Ozkorucuklu, E. Paganis, C. A. Palmer, S. Pandey, F. Pantaleo, C. Papageorgakis, I. Papakrivopoulos, M. Paranjpe, J. Parshook, N. Pastika, M. Paulini, T. Peitzmann, T. Peltola, N. Peng, A. Buchot Perraguin, P. Petiot, T. Pierre-Emile, M. Vicente Barreto Pinto, E. Popova, R. Pöschl, H. Prosper, M. Prvan, I. Puljak, S. R. Qasim, H. Qu, T. Quast, R. Quinn, M. Quinnan, A. Rane, K. K. Rao, K. Rapacz, L. Raux, W. Redjeb, M. Reinecke, M. Revering, F. Richard, A. Roberts, A. M. Sanchez, J. Rohlf, J. Rolph, T. Romanteau, M. Rosado, A. Rose, M. Rovere, A. Roy, P. Rubinov, R. Rusack, V. Rusinov, V. Ryjov, O. M. Sahin, R. Salerno, R. Saradhy, T. Sarkar, M. A. Sarkisla, J. B. Sauvan, I. Schmidt, M. Schmitt, S. Schuwalow, E. Scott, C. Seez, F. Sefkow, D. Selivanova, S. Sharma, M. Shelake, A. Shenai, R. Shukla, E. Sicking, M. De, P. Silva, P. Simkina, F. Simon, A. E. Simsek, Y. Sirois, V. Smirnov, T. J. Sobering, E. Spencer, N. Srimanobhas, A. Steen, J. Strait, N. Strobbe, X. F. Su, Y. Sudo, C. Mantilla Suarez, E. Sukhov, L. Sulak, L. Sun, P. Suryadevara, C. Syal, C. de La Taille, B. Tali, C. L. Tan, J. Tao, A. Tarabini, T. Tatli, R. Thaus, R. D. Taylor, S. Tekten, A. Thiebault, D. Thienpont, C. Tiley, E. Tiras, M. Titov, D. Tlisov, U. G. Tok, A. Kayis, J. Troska, L. S. Tsai, Z. Tsamalaidze, G. Tsipolitis, A. Tsirou, S. Undleeb, D. Urbanski, E. Uslan, V. Ustinov, A. Uzunian, J. Varela, M. Velasco, E. Vernazza, O. Viazlo, P. Vichoudis, T. Virdee, E. Voirin, M. Vojinovi\c, M. Vojinovic, A. Wade, C. Wang, C. C. Wang, D. Wang, F. Wang, X. Wang, X. Wang, Z. Wang, M. Wayne, S. N. Webb, A. Whitbeck, R. Wickwire, J. S. Wilson, H. Y. Wu, L. Wu, M. Xiao, J. Yang, C. H Yeh, R. Yohay, D. Yu, S. S. Yu, C. Yuan, Y. Miao, F. Yumiceva, I. Yusuff, A. Zabi, A. Zacharopoulou, N. Zamiatin, A. Zarubin, P. Zehetner, D. Zerwas, H. Zhang, J. Zhang, Y. Zhang, Z. Zhang, X. Zhao
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly readout by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.
CMS实验中的CASTOR量热计是一种电磁/强子量热计,它覆盖了探测器的非常前面的区域(-6.6 < eta < -5.2)。CASTOR是切伦科夫取样量热计,由石英和钨板组成,总深度为10个相互作用长度,能够探测穿透级联粒子。它分为16个横向部分和14个纵向部分。围绕束管,其设计由空间限制决定,并限于耐受高辐射水平的材料。在本报告中,我们报告的操作经验和测量与CASTOR量热计在2010年的数据采取在大型强子对撞机,质子-质子和重离子碰撞。广泛的物理程序,可以访问与CASTOR的概述,以及已发表的和正在进行的物理分析和探测器研究的状态。
The CMS High-Granularity Calorimeter for Operation at the High-Luminosity LHC
高亮度LHC(HL-LHC)将集成比LHC高10倍的亮度,对探测器的辐射耐受性和事件堆积提出了重大挑战,特别是对于前向量热法,并标志着未来对撞机的问题。作为其HL-LHC升级计划的一部分,CMS合作正在设计一种高粒度量热计,以取代现有的端盖量热计。它具有前所未有的横向和纵向分割电磁(ECAL)和强子(HCAL)隔间。这将促进粒子流量热法,其中可以测量簇射的精细结构并用于增强堆积排斥和粒子识别,同时仍然实现良好的能量分辨率。ECAL和大部分HCAL将基于0.5至1 cm $^2$单元尺寸的六边形硅传感器,其余HCAL基于具有SiPM读出的高度分段的放大器。硅传感器固有的高精度计时能力将为事件重建增加额外的维度,特别是在堆积拒绝方面。HGCAL项目的概述,包括动机,工程设计,读出和触发的概念,和预期的性能。
Application of sequence learning for predicting radiation damage of the CMS electromagnetic calorimeter
Facultad de Ciencias, Universidad Nacional Autónoma de México(墨西哥国立自治大学理学院);Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México(墨西哥国立自治大学核科学研究所)
Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter