arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2204.00459cond-mat.mtrl-sciphysics.app-ph
收藏

金属卤化物超导器件空间电荷限制电流测量的有效窗口

The Validity Window of Space-Charge-Limited Current Measurements of Metal Halide Perovskite Devices

William R. Fisher, Philip Calado, Jason A. Röhr, Joel A. Smith, Xingyuan Shi, Onkar Game, Jenny Nelson, Piers R. F. Barnes

摘要:

空间电荷限制电流(SCLC)测量通过分析由Mott-Gurney(MG)定律预测的单极器件的电流密度-电压(JV)关系来估计半导体的载流子迁移率和电子陷阱密度。然而,金属卤化物钙钛矿的SCLC测量的解释是有问题的,这是由于在测量期间重新分布以屏蔽器件中的静电场的移动离子缺陷。为了克服这一点,最近提出了SCLC测量方案,该方案通过在叠加在背景偏压上的毫秒电压脉冲期间探测电流来最小化离子电荷再分布。在这里,我们使用漂移扩散模拟与移动离子来评估MG法的有效性分析标准和新协议JV测量。我们模拟了具有不同移动离子密度的理想化钙钛矿设备,并将其与具有典型接触材料的设备的模拟和测量进行了比较。我们发现,MG定律的有效区域仅限于可移动离子密度低于器件平衡载流子密度(对于400 nm厚的甲基铵碘化铅薄膜,小于10^17 cm-3)且接触注入/提取势垒<=0.1 eV的钙钛矿。后一种限制可以通过增加器件厚度来部分克服,而前一种限制则不能。这限制了可以用MG定律可靠分析的钙钛矿层成分和可行接触材料的范围。方法,如估计陷阱密度从表观电压开始无陷阱SCLC制度也应严格审查,因为它们依赖于相同的潜在无效的假设,作为MG法律。我们的研究结果表明,从SCLC中提取金属卤化物钙钛矿材料特性的有意义和准确的值可能具有挑战性,或者通常是不可能的。

英文摘要:

Space-charge-limited current (SCLC) measurements are used to estimate charge carrier mobilities and electronic trap densities of semiconductors by analysing the current density-voltage (JV) relationship for unipolar devices predicted by the Mott-Gurney (MG) law. However, the interpretation of SCLC measurements for metal-halide perovskites is problematic due to mobile ionic defects which redistribute to screen electrostatic fields in devices during measurements. To overcome this, an SCLC measurement protocol was recently suggested that minimises ionic charge redistribution by probing the current during millisecond voltage pulses superimposed on a background bias. Here, we use drift-diffusion simulations with mobile ions to assess the validity of the MG law for analysing both the standard and new protocol JV measurements. We simulated idealised perovskite devices with differing mobile ion densities and compared them with simulations and measurements of devices with typical contact materials. We found the validity region for the MG law is limited to perovskites with mobile ion densities lower than the device's equilibrium charge carrier density (<10^17 cm-3 for 400 nm thick methylammonium lead iodide films) and contacts with injection/extraction barriers <=0.1 eV. The latter limitation can be partially overcome by increasing the device thickness, whereas the former limitation cannot. This restricts the range of perovskite layer compositions and viable contact materials that can be reliably analysed with the MG law. Approaches such as estimating trap densities from the apparent voltage onset to trap-free SCLC regime should also be critically reviewed since they rely on the same potentially invalid assumptions as the MG law. Our results demonstrate that extracting meaningful and accurate values for metal halide perovskite material properties from SCLC maybe challenging, or often not possible.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑