A simulation model is developed to train Artificial Neural Networks (ANN), for precise timing of PICOSEC Micromegas detector signals. The aim is to develop fast, online timing algorithms as well as minimising the information to be saved during data acquisition. PICOSEC waveforms were collected and digitised by a fast oscilloscope during a femptosecond-laser test beam run. A data set comprising waveforms collected with attenuated laser beam intensity, eradicating the emission of more than one photoelectron per light pulse from the PICOSEC photocathode, was utilised by a simulation algorithm to generate waveforms to train an ANN. A second data set of multi-photoelectron waveforms was used to evaluate the ANN performance in determining the PICOSEC Signal Arrival Time, relative to a fast photodiode time-reference. The ANN timing performance is the same as the results of a full offline signal processing, achieving a timing precision of 18.3$\pm$0.6 ps.
The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in technology for charged particle timing at high rates. In contrast to the role of timing for particle identification, which has driven incremental improvements in timing, the LHC timing challenge dictates a specific level of timing performance- roughly 20-30 picoseconds. Since the elapsed time for an LHC bunch crossing (with standard design book parameters) has an rms spread of 170 picoseconds, the $\sim50-100$ picosecond resolution now commonly achieved in TOF systems would be insu…
We report experimental test-beam results on dielectric-loaded waveguide detectors that utilize microwave Cherenkov signals to time and characterize high energy particle showers. These results are used to validate models and produce high-fidelity simulations of timing plane systems which yield picosecond time tags and millimeter spatial coordinates for the shower centroid. These timing planes, based on the Askaryan effect in solid dielectrics, are most effective at the high center-of-momentum energies planned for the Future Circular Collider (FCC-hh), and are of particular interest in the forwa…
Using the Belle detector we study the characteristics of beam collisions at the KEKB 3.5 GeV $e^+$ on 8 GeV $e^-$ asymmetric energy collider. We investigate the collision timing {\tip} and its $z$-coordinate along the beam axis {\zip} as a function of the position of the colliding bunch in a beam train. The various {\tip} and {\zip} behaviors observed by Belle are attributed to beam loading effects in the radio frequency cavities that accelerate the beams with a beam abort gap. We report these results in detail and discuss the prospects for the SuperKEKB collider.
Liquid-scintillator-based detectors are a robust technology that scales well to large volumes. For this reason, they are attractive for experiments searching for neutrinoless double-beta decay. A combination of improved photo-detection technology and novel liquid scintillators may allow for the extraction of particle direction in addition to the total energy of the particle. Such an advance would find applications beyond searches for neutrinoless double-beta decay.
We report on the first measurements of coherent microwave impulses from high-energy particle-induced electromagnetic showers generated via the Askaryan effect in a dielectric-loaded waveguide. Bunches of 12.16 GeV electrons with total bunch energy of $\sim 10^3-10^4$ GeV were pre-showered in tungsten, and then measured with WR-51 rectangular (12.6 mm by 6.3 mm) waveguide elements loaded with solid alumina ($Al_2 O_3$) bars. In the 5-8 GHz $TE_{10}$ single-mode band determined by the presence of the dielectric in the waveguide, we observed band-limited microwave impulses with amplitude proporti…
This paper presents results that take a critical step toward proving 10 ps timing resolution's feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of 35 micro-m and 50 micro-m are evaluated with a 120 GeV proton beam. The performance of the gain and timing response is assessed, including the dependence on the reverse bias voltage and operating temperature. The best timing resolution of UFSDs in a test beam to date is achieved using three combined planes of 35 micro-m thick LGADs at -30 degree celsius with…
The fast timing MPGD is a micro-pattern gaseous detector conceived for achieving sub-nanosecond time resolution while maintaining the ability to instrument large areas in high-rate environments; applications of such technology are perspected in high-energy physics experiments at future colliders and medical diagnostics with time-of-flight methods. This work shows the systematic studies carried on an FTM prototype on the performance of GEM foils coated with resistive DLC films, whose development is essential for the FTM operation. The resistive foil performance has been tested with several gas …
We give a short compendium of the main ongoing detectors and concepts capable of performing accurate sub-100 ps timing at high particle fluxes and on large areas, through technologies based on gaseous media. We briefly discuss the state-of-the-art, technological limitations and prospects, and a new bizarre idea.
TORCH is a large-area, high-precision time-of-flight (ToF) detector designed to provide charged-particle identification in the 2-20 GeV$/c$ momentum range. Prompt Cherenkov photons emitted by charged hadrons as they traverse a 10mm quartz radiator are propagated to the periphery of the detector, where they are focused onto an array of micro-channel plate photomultiplier tubes (MCP-PMTs). The position and arrival times of the photons are used to infer the particles' time of entry in the radiator, to identify hadrons based on their ToF. The MCP-PMTs were developed with an industrial partner to s…
Caribou is a flexible open-source DAQ system developed and used within several collaborative frameworks (CERN EP R&D, RD50, AIDAinnova) for laboratory and high-rate beam tests and easy integration of new silicon-pixel detector prototypes. It uses common hardware, firmware and software components that are shared across different projects, thereby reducing the development effort and cost for such readout systems significantly. This contribution introduces the FASTPIX, APTS and DPTS detectors recently integrated in Caribou and their requirements in terms of waveform sampling and timing of digital…
Micro-channel plate (MCP)-based photodetectors are capable of picosecond level time resolution and sub-mm level position resolution, which makes them a perfect candidate for the next generation large area photodetectors. The large-area picosecond photodetector (LAPPD) collaboration is developing new techniques for making large-area photodetectors based on new MCP fabrication and functionalization methods. A small single tube processing system (SmSTPS) was constructed at Argonne National Laboratory (ANL) for developing scalable, cost-effective, glass-body, 6 cm x 6 cm, picosecond photodetectors…
In recent years important progress in micropattern gaseous detectors has been achieved in the use of resistive material to build compact spark-protected devices. The novel idea presented here consists of the polarisation of WELL structures using only resistive coating. This allows a new device to be built with an architecture based on a stack of several coupled layers where drift and WELL multiplication stages alternate in the structure. The signals from each multiplication stage can be read out from any external readout boards through the capacitive couplings. Each layer provides a signal wit…
The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that such a device, scalable to a larger area, provides excellent time resolution and detection efficiency. As expected from earlier single-cell device studies, we measure a time resolution of approximately 25 picoseconds for charged particles hitting near the anode pad centers, and up to 30 picoseconds at the pad edges. Here, we study in detail the effect of dr…
The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in developing technologies for charged particle detection with accurate timing at high rates. The required accuracy follows directly from the nominal interaction distribution within a bunch crossing ($σ_z\sim5$ cm, $σ_t\sim170$ ps). A time resolution of the order of 20-30 ps would lead to significant reduction of these backgrounds. With this goal, we present a new detection concept called PICOSEC, which is based on a "two-stage" Micromegas detector coupled to a Cherenkov radiator and …
Ultra Fast Silicon Detectors (UFSD) are sensors optimized for timing measurements employing a thin multiplication layer to increase the output signal. A multipurpose read-out board hosting a low-cost, low-power fast amplifier was designed at the University of Kansas and tested at the European Organization for Nuclear Research (CERN) using a 180 GeV pion beam. The amplifier has been designed to read out a wide range of detectors and it was optimized in this test for the UFSD output signal. In this paper we report the results of the experimental tests using 50 $\rm{μm}$ thick UFSD with a sensiti…
In planning for the Phase II upgrades of CMS and ATLAS major considerations are: 1)being able to deal with degradation of tracking and calorimetry up to the radiation doses to be expected with an integrated luminosity of 3000 $fb^{-1}$ and 2)maintaining physics performance at a pileup level of ~140. Here I report on work started within the context of the CMS Forward Calorimetry Task Force and continuing in an expanded CERN RD52 R$&$D program integrating timing (i.e. measuring the time-of-arrival of physics objects) as a potential tool for pileup mitigation and ideas for Forward Calorimetry. Fo…
Picosecond-level timing will be an important component of the next generation of particle physics detectors. The ability to add a 4$^{th}$ dimension to our measurements will help address the increasing complexity of events at hadron colliders and provide new tools for precise tracking and calorimetry for all experiments. Detectors are described in detail on other whitepapers. In this note, we address challenges in electronics design for the new generations of fast timing detectors
This paper describes a new radio frequency timer of keV energy electrons. It is based on a helical deflector, which performs circular or elliptical sweeps of keV electrons, by means of 500 MHz radio frequency field. By converting a time distribution of incident electrons to a hit position distribution on a circle or ellipse, this device achieves extremely precise timing. Streak Cameras, based on similar principles, routinely operate in the ps and sub-ps time domain, but have substantial dead time associated with the readout system. Here, we report a new type of RF timing technique, where the p…
The PICOSEC detection concept consists in a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. A proof of concept has already been tested: a single-photoelectron response of 76 ps has been measured with a femtosecond UV laser at CEA/IRAMIS, while a time resolution of 24 ps with a mean yield of 10.4 photoelectrons has been measured for 150 GeV muons at the CERN SPS H4 secondary line. This work will present the main results of this prototype and the performance of the different detector configurations tested in 2016-18 beam campaigns: readouts (bulk…
The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in technology for charged particle timing at high rates\cite{challenge}. In this paper I report on a framework for fast timing sensor and related electronics development used primarily within the context of PICOSEC. Our collaboration accumulated a large ($\sim$fewTbyte) set of waveforms from timing sensors based on MicroChannel Plates(MCP), MicroPattern Gas Detectors(MPGD) and capacitive readout Avalanche Diodes (aka HFS) with typically 20-40 GSa/s waveform sampling. We have reported …
The design and performance of a multi-G-sample/s fully-synchronous analog transient waveform recorder I.C. ("SST") with fast and flexible trigger capabilities is presented. Containing 4 channels of 256 samples per channel and fabricated in a 0.25 μm CMOS process, it has a 1.9V input range on a 2.5V supply, achieves 12 bits of dynamic range, and uses ~160 mW while operating at 2 G-samples/s and full trigger speeds. With a standard 50 Ohm input source, the SST's analog input bandwidth is ~1.3 GHz within about +/-0.5 dB and reaches a -3 dB bandwidth of 1.5 GHz. The SST's internal sample clocks ar…
The PhaseII Upgrades of CMS are being planned for the High Luminosity LHC (HL-LHC) era when the mean number of interactions per beam crossing ("in-time pileup") is expected to reach ~140-200. The potential backgrounds arising from mis-associated jets and photon showers, for example, during event reconstruction could be reduced if physics objects are tagged with an "event time". This tag is fully complementary to the "event vertex" which is already commonly used to reduce mis-reconstruction. Since the tracking vertex resolution is typically ~10^{-3} (50 micron/4.8cm) of the rms vertex distribut…
The SAMpler for PICosecond time (SAMPIC) chip has been designed by a collaboration including CEA/IRFU/SEDI, Saclay and CNRS/LAL/SERDI, Orsay. It benefits from both the quick response of a time to digital converter and the versatility of a waveform digitizer to perform accurate timing measurements. Thanks to the sampled signals, smart algorithms making best use of the pulse shape can be used to improve time resolution. A software framework has been developed to analyse the SAMPIC output data and extract timing information by using either a constant fraction discriminator or a fast cross-correla…
For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must maintain the performance of the sensor, while keeping low power consumption. This paper presents the results on the first prototype of a front-end ASIC, named ALTIROC0, which contains the analog stages (preamplifier an…
Group III-V semiconductor materials are being considered as a Si replacement for advanced logic devices for quite some time. Advances in III-V processing technologies, such as interface and surface passivation, large area deep submicron lithography with high-aspect ratio etching primarily driven by the MOSFET development can also be used for other applications. In this paper we will focus on photodetectors with the drift field parallel to the surface. We compare the proposed concept to the state-of-the-art Si-based technology and discuss requirements which need to be satisfied for such detecto…
We propose and demonstrate a method to characterize a gated InGaAs single-photon detector (SPD). Ultrashort weak coherent pulses, from a mode-locked sub-picosecond pulsed laser, were used to measure photon counts, at varying arrival times relative to the start of the SPD gate voltage. The uneven detection probabilities within the gate window were used to estimate the afterpulse probability with respect to various detector parameters: excess bias, width of gate window and hold-off time. We estimated a lifetime of 2.1 microseconds for the half-life of trapped carriers, using a power-law fit to t…
We describe the main components of the ATLAS Forward Physics project, namely the movable beam pipe, the tracking and timing detectors which allow to detect intact protons in the final state at the LHC. The position detector is composed on 6 layers of 3D silicon detectors readout by FE-I4 chips developped for ATLAS. The fast timing detector is built from a quartz-based Cerenkov detector coupled to a microchannel plate photomultiplier tube, followed by the electronic elements that amplify, measure, and record the time of the event along with a stabilized reference clock signal, ensuring a time r…
UV lasers for the calibration of gaseous detectors have seen newfound employment with current-generation micro-pattern gaseous detectors (MPGDs), especially those devices not suitable for tests with traditional sources (e.g. cosmic rays or X-ray beams) by design constraints. An apparatus made of a UV laser designed for the characterization of the fast timing MPGD (FTM) is here described, together with the measurements of gain curve and electron drift velocity performed on a prototype of Time Projection GEM (TPG) to validate the setup.
The planned luminosity increase at the Large Hadron Collider in the coming years has triggered interest in the use of the particles' time of arrival as additional information in specialized detectors to mitigate the impact of pile-up. The required time resolution is of the order of tens of picoseconds, with a spatial granularity of the order of 1 mm. A time measurement at this precision level will also be of interest beyond the LHC and beyond high energy particle physics. We present in this paper the first developments towards a radiation hard Depleted Monolithic Active Pixel Sensor (DMAPS), w…
In this paper we present a complete characterization of the first batch of Resistive AC-Coupled Silicon Detectors, called RSD1, designed at INFN Torino and manufactured by Fondazione Bruno Kessler (FBK) in Trento. With their 100% fill-factor, RSD represent the new enabling technology for high-precision 4D-tracking. Indeed, being based on the well-known charge multiplication mechanism of Low-Gain Avalanche Detectors (LGAD), they benefit from the very good timing performances of such technology together with an unprecedented resolution of the spatial tracking, which allows to reach the micron-le…
We study the impact of picosecond precision timing detection systems on the LHC experiments' long-lived particle search program during the HL-LHC era. We develop algorithms that allow us to reconstruct the mass of such charged particles and perform particle identification using the time-of-flight measurement. We investigate the reach for benchmark scenarios as a function of the timing resolution, and find sensitivity improvement of up to a factor of ten, depending on the new heavy particle mass.
Temperature Dependence of Gain and Time Resolution in LGAD Detectors
Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);University of Chinese Academy of Sciences(中国科学院大学);Spallation Neutron Source Science Center(散裂中子源科学中心)
We report on performance results achieved for recently produced LAPPDs - largest comercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to $10^{7}$, low dark noise rates ($\sim$100 Hz/cm$^{2}$ at a gain of $6\cdot10^6$), single photoelectron (PE) timing resolution of $\sim$50 picoseconds RMS (electronics limited), and single photoelectron spatial resolution along and across strips of 3.2mm (electronics limited) and 0.8 mm RMS respectively and high (about 25\% or higher in some units) QE uniform bi-alkali photocathodes. LAPP…
Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET
Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学);CERN(欧洲核子研究组织);Stony Brook University(石溪大学);NCSR Demokritos(德墨忒勒斯国家科学研究中心);University of Bonn(波恩大学);LIP(粒子物理与实验仪器实验室);University of Helsinki(赫尔辛基大学);Jefferson Lab(杰斐逊实验室);University of Zagreb(萨格勒布大学);University of Science and Technology of China(中国科学技术大学);CEA-Saclay(法国原子能和替代能源委员会萨克雷中心);National Technical University of Athens(雅典国立技术大学);Ruđer Bošković Institute(鲁德·博什科维奇研究所);University of Virginia(弗吉尼亚大学)
Recent interest in pile-up mitigation through fast timing at the HL-LHC has focused attention on technologies that now achieve minimum ionising particle (MIP) time resolution of 30 picoseconds or less. The constraints of technical maturity and radiation tolerance narrowed the options in this rapidly developing field for the ATLAS and CMS upgrades to low gain avalanche detectors and silicon photomultipliers. In a variety of applications where occupancies and doses are lower, devices with pixel elements of order 1 cm$^2$, nevertheless achieving 30 ps, would be attractive. In this paper, deep dif…
The development of Low-Gain Avalanche Detectors has opened up the possibility of manufacturing silicon detectors with signal larger than that of traditional sensors. In this paper we explore the timing performance of Low-Gain Avalanche Detectors, and in particular we demonstrate the possibility of obtaining ultra-fast silicon detector with time resolution of less than 20 picosecond.
Since long time, the compelling scientific goals of future high energy physics experiments were a driving factor in the development of advanced detector technologies. A true innovation in detector instrumentation concepts came in 1968, with the development of a fully parallel readout for a large array of sensing elements - the Multiwire Proportional Chamber (MWPC), which earned Georges Charpak a Nobel prize in physics in 1992. Since that time radiation detection and imaging with fast gaseous detectors, capable of economically covering large detection volume with low mass budget, have been play…
We analyze the origin of the intrinsic timing jitter in superconducting nanowire single photon detectors (SNSPDs) in terms of fluctuations in the latency of the detector response, which is determined by the microscopic physics of the photon detection process. We demonstrate that fluctuations in the physical parameters which determine the latency give rise to the intrinsic timing jitter. We develop a general description of latency by introducing the explicit time dependence of the internal detection efficiency. By considering the dynamic Fano fluctuations together with static spatial inhomogene…
μRWELL-PICOSEC: Precision Timing with Resistive Micro-Well Detector
Thomas Jefferson National Accelerator Facility(托马斯·杰斐逊国家加速器设施);IRFU, CEA, Université Paris-Saclay(IRFU, 法国原子能和替代能源委员会, 巴黎萨克雷大学);Department of Physics, Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学物理系);Center for Interdisciplinary Research and Innovation (CIRI-AUTH)(跨学科研究与创新中心);Department for Medical Physics, Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学医学物理系);European Organization for Nuclear Research (CERN)(欧洲核子研究组织);Dipartimento di Fisica, Università di Pavia(帕维亚大学物理系);INFN Sezione di Pavia(意大利国家核物理研究所帕维亚分部);Department of Physics and Astronomy, Stony Brook University(石溪大学物理与天文学系);Institute of Nuclear and Particle Physics, NCSR Demokritos(国家科学研究中心德谟克利特研究所核与粒子物理研究所)
Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with $10 \times 10\ \mathrm{cm}^{2}$ active area
European Organization for Nuclear Research (CERN)(欧洲核子研究中心);Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Center for Interdisciplinary Research and Innovation (CIRI-AUTH)(跨学科研究与创新中心);Institut de Recherche sur les lois Fondamentales de l’Univers (IRFU, CEA)(基础定律宇宙研究所);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学)
Microchannel plate photodetectors provide both picosecond time resolution and sub-millimeter position resolution, making them attractive photosensors for particle identification detectors of a future U.S. Electron Ion Collider. We have tested the rate capability and magnetic field tolerance of 6$\times$6 cm$^{2}$ microchannel plate photodetectors fabricated at Argonne National Laboratory. The microchannel plate photodetector is designed as a low-cost all-glass vacuum package with a chevron pair stack of next-generation microchannel plates functionalized by atomic layer deposition. The rate cap…
The potential of photon detectors to achieve precise timing information is of increasing importance in many domains, PET and CT scanners in medical imaging and particle physics detectors, amongst others. The goal to increase by an order of magnitude the sensitivity of PET scanners and to deliver, via time-of-flight (TOF), true space points for each event, as well as the constraints set by future particle accelerators require a further leap in time resolution of scintillator-based ionizing radiation detectors, reaching eventually a few picoseconds resolution for sub MeV energy deposits. In spit…
Many of the yet unanswered questions in neutrino physics, such as CP violation in the lepton sector or neutrino mass hierarchy, could be answered with higher sensitivity neutrino experiments. New photodetectors based on micro-channel plates are being developed by the Large-Area Picosecond Photo Detector (LAPPD) Collaboration. These photosensors have been shown to have excellent spatial and timing resolution. Using these devices in massive water Cherenkov detectors, we could significantly improve the vertex resolution for neutrinos enhancing background rejection for neutrino oscillation experim…
This work aims at the development of signal processing algorithms that can explore the potential of a PICOSEC-MicroMegas detector and offers the ability for online, precise timing. The PICOSEC-MicroMegas detector is a novel gaseous detector offering precise timing resolution in experimental measurements. The performance of the proposed signal processing algorithms is evaluated by a variety of tests using experimental data. The data used in the present research were accumulated during a Laser Beam Test at CEA/IRAMIS-SACLAY. We use two sets of experimental events: the SPE-set comprises single ph…