A novel Compton Scanner setup has been built, commissioned and operated at the Max-Planck-Institute for Physics in Munich to collect pulses from bulk events in high-purity germanium detectors for pulse shape studies. In this fully automated setup, the detector under test is irradiated from the top with 661.660 keV gammas, some of which Compton scatter inside the detector. The interaction points in the detector can be reconstructed when the scattered gammas are detected with a pixelated camera placed at the side of the detector. The wide range of accepted Compton angles results in shorter measurement times in comparison to similar setups where only perpendicularly scattered gammas are selected by slit collimators. In this paper, the construction of the Compton Scanner, its alignment and the procedure to reconstruct interaction points in the germanium detector are described in detail. The creation of a first pulse shape library for an n-type segmented point-contact germanium detector is described. The spatial reconstruction along the beam axis is validated by a comparison to measured surface pulses. A first comparison of Compton Scanner pulses to simulated pulses is presented to demonstrate the power of the Compton Scanner to test simulation inputs and models.
Three-dimensional Compton imaging of undepleted volumes of germanium detectors
Max-Planck-Institut für Physik(马克斯·普朗克物理研究所);Space Sciences Laboratory, University of California, Berkeley(加州大学伯克利分校空间科学实验室);University of North Carolina(北卡罗来纳大学);Triangle Universities Nuclear Laboratory(三角大学核实验室);Technical University of Munich(慕尼黑工业大学);Max-Planck-Institut für Kernphysik(马克斯·普朗克核物理研究所)
Pulse shape discrimination studies with a Broad-Energy Germanium detector for signal identification and background suppression in the GERDA double beta decay experiment
Comparison of the x-ray tube spectrum measurement using BGO, NaI, LYSO, and HPGe detectors in a preclinical mini-CT scanner: Monte Carlo simulation and practical experiment
Towards polarization-enhanced PET: Study of random background in polarization-correlated Compton events
University of Zagreb, Faculty of Science(萨格勒布大学理学院);Institute for Medical Research and Occupational Health(医学研究与职业健康研究所);University Hospital Centre Zagreb(萨格勒布大学医院中心);Kuopio University Hospital, University of Eastern Finland(库奥皮奥大学医院,东芬兰大学);Juraj Dobrila University(尤拉伊·多布里拉大学);Medi-lab d.o.o.(Medi-lab有限责任公司)
Nonproportional Response of a GAGG Scintillator to Beta and Gamma Radiation over a Wide Energy Range in PIKACHU
University of Tsukuba(筑波大学);Mirion Technologies (Canberra) KK(美林科技(堪培拉)有限公司);Tohoku University(东北大学);C&A Corporation(C&A公司);Tokushima University(德岛大学);Obihiro University of Agriculture and Veterinary Medicine(带广畜产大学);The University of Osaka(大阪大学)