锗探测器未耗尽体积的康普顿成像
Three-dimensional Compton imaging of undepleted volumes of germanium detectors
AI总结:
本研究通过康普顿成像技术首次获得锗探测器未耗尽体积的三维图像,并用于推导杂质密度分布。
摘要:
通过测量空间分辨的康普顿散射效率,对p型高纯广能锗探测器未耗尽体积的形状进行了成像,该形状取决于偏压电压。偏压电压分阶段从-50 V升至完全耗尽电压。在完全耗尽时确定了几何接受度。在完全耗尽以下,对于2×2×2 mm³的体素,观察到的相对接受度用于为每个偏压电压创建未耗尽体积的图像。这些图像用于通过拟合开源软件包SolidStateDetectors.jl的预测来提取探测器的杂质密度分布。结果进行了展示并与通过电容测量推导出的杂质密度分布进行了比较。这是首次获得锗探测器未耗尽体积的三维图像,并利用这些图像推导出杂质密度分布。
英文摘要:
The shape of the undepleted volume of a p-type Broad Energy Germanium detector has been imaged at various bias voltages by measuring spatially-resolved three-dimensional Compton-scattering efficiency. The bias voltage was raised stepwise from $-50\,\text{mm}$ to the full-depletion voltage.The geometric acceptance was determined at full depletion. Below full depletion, the relative acceptance observed for $2\times2\times2\,\text{mm}^3$ voxels was used to create the image of the undepleted volume for each bias voltage. The images were fitted with predictions from the open-source software package SolidStateDetectors$.$jl to extract the radial impurity density profile of the detector. The strong radial decrease in the impurity density obtained in the outermost centimeter was validated using independent capacitance measurements. This novel method to determine the impurity density via three-dimensional Compton-scattering efficiency maps provides a powerful tool for advanced detector bulk characterization.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。