Upgrade of the CMS Resistive Plate Chambers for the High Luminosity LHC
A. Samalan, M. Tytgat, G. A. Alves, F. Marujo, F. Torres Da Silva De Araujo, E. M. DaCosta, D. De Jesus Damiao, H. Nogima, A. Santoro, S. Fonseca De Souza, A. A… 展开作者
A. Samalan, M. Tytgat, G. A. Alves, F. Marujo, F. Torres Da Silva De Araujo, E. M. DaCosta, D. De Jesus Damiao, H. Nogima, A. Santoro, S. Fonseca De Souza, A. Aleksandrov, R. Hadjiiska, P. Iaydjiev, M. Rodozov, M. Shopova, G. Soultanov, M. Bonchev, A. Dimitrov, L. Litov, B. Pavlov, P. Petkov, A. Petrov, S. J. Qian, C. Bernal, A. Cabrera, J. Fraga, A. Sarkar, S. Elsayed, Y. Assran, M. El Sawy, M. A. Mahmoud, Y. Mohammed, C. Combaret, M. Gouzevitch, G. Grenier, I. Laktineh, L. Mirabito, K. Shchablo, I. Bagaturia, D. Lomidze, I. Lomidze, V. Bhatnagar, R. Gupta, P. Kumari, J. Singh, V. Amoozegar, B. Boghrati, M. Ebraimi, R. Ghasemi, M. Mohammadi Najafabadi, E. Zareian, M. Abbrescia, R. Aly, W. Elmetenawee, N. DeFilippis, A. Gelmi, G. Iaselli, S. Leszki, F. Loddo, I. Margjeka, G. Pugliese, D. Ramos, M. Caponero, L. Benussi, S. Bianco, S. Colafranceschi, A. Russo, L. Passamonti, D. Piccolo, D. Pierluigi, G. Saviano, S. Buontempo, A. Di Crescenzo, F. Fienga, G. DeLellis, L. Lista, S. Meola, P. Paolucci, A. Braghieri, P. Salvini, P. Montagna, C. Riccardi, P. Vitulo, B. Francois, T. J. Kim, J. Park, S. Y. Choi, B. Hong, K. S. Lee, J. Goh, H. Lee, J. Eysermans, C. Uribe Estrada, I. Pedraza, H. Castilla-Valdez, A. Sanchez-Hernandez, C. A. Mondragon Herrera, D. A. Perez Navarro, G. A. AyalaSanchez, S. Carrillo, E. Vazquez, N. Zaganidis, A. Radi, A. Ahmad, I. Asghar, H. Hoorani, S. Muhammad, M. A. Shah, B. Mandelli, R. Guida, I. Crotty
During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates, event pileup, and the probable aging of the current detectors present a challenge for all the existing experiments at the LHC, including the Compact Muon Solenoid (CMS) experiment. To ensure a highly performing muon system for this period, several upgrades of the Resistive Plate Chamber (RPC) system of the CMS are currently being implemented. These include the replacement of the readout system for the present system, and the installation of two new RPC stations with improved chamber and front-end electronics designs. The current overall status of this CMS RPC upgrade project is presented.
The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013-2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with…
The Resistive Plate Chambers detector system at the CMS experiment at the LHC provides robustness and redundancy to the muon trigger. A total of 1056 double-gap chambers cover the pseudo-rapidity region < 1.6. The main detector parameters and environmental conditions are constantly and closely monitored to achieve operational stability and high quality data in the harsh conditions of the second run period of the LHC with center-of-mass energy of 13 TeV. First results of overall detector stability with 2015 data and comparisons with data from the LHC RUN-1 period at 8 TeV are presented.
The limitation of the detection rate of standard bakelite resistive plate chambers (RPC) used as muon detectors in the LHC experiments has prevented the use of such detectors in the high rate regions in both CMS and ATLAS detectors. One alternative to these detectors are RPCs made with low resistivity glass plates ($10^{10} {\rm Ω.cm}$), a beam test at DESY has shown that such detectors can operate at few thousand Hz/cm$^2$ with high efficiency(> 90%)
The CMS inner pixel detector system is planned to be replaced during the first phase of the LHC luminosity upgrade. The plans foresee an ultra low mass system with four barrel layers and three disks on either end. With the expected increase in particle rates, the electronic readout chain will be changed for fast digital signals. An overview of the envisaged design options for the upgraded CMS pixel detector is given, as well as estimates of the tracking and vertexing performance.
The high flux of charged particles interacting with the CMS Forward Hadron Calorimeter PMT windows introduced a significant background for the trigger and offline data analysis. During Long Shutdown 1, all of the original PMTs were replaced with multi-anode, thin window photomultiplier tubes. At the same time, the back-end electronic readout system was upgraded to μTCA readout. The experience with commissioning and calibration of the Forward Hadron Calorimeter is described as well as the μTCA system. The upgrade was successful and provided quality data for Run 2 data-analysis at 13 TeV.
A new pixel detector for the CMS experiment is being built, owing to the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking while featuring a significantly reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and comprises a low-threshold comparator. These improvements allow the new pixel detector to sustain and improve the efficiency of the current pixel tracker at the increased requirements imposed by high luminosities and p…
The next upgrade of the Large Hadron Collider (LHC) is planned from 2026 when the collider will move to its High Luminosity phase (HL-LHC). The CMS detector needs to be substantially upgraded during this period to exploit the fourfold increase in luminosity provided by the HL-LHC. This upgrade is referred to as the CMS Phase-2 Upgrade. A program of laboratory and beam test measurements, and performance studies based on the detailed simulation of the detector was carried out to support the decision of the technology of the sensors to be adopted in the different regions of the detector for the P…
The operations of Resistive Plate Chambers in LHC experiments require Fluorine based (F-based) gases for optimal performance. Recent European regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In view of the CMS experiment upgrade, several tests are ongoing to measure the performance of the detector with these new ecological gas mixtures, in terms of efficiency, streamer probability, induced charge and time resolution. Prototype chambers with readout pads and with the standard CMS electronic setup are under test. In this paper preliminary results on…
In the upcoming years, with the upgrade of the LHC to higher luminosities, CMS will be subject to an increasing flux of particles, especially in its most forward region, at | η| > 1.6. To consolidate the muon spectrometer of CMS and increase redundancy, the CMS GEM collaboration proposes to instrument the 1.6 < | η| < 2.1 region, originally foreseen to be equipped with RPC, with Triple-GEM detectors. This technology has proven to remain efficient under high fluxes and meets the requirements of CMS. This work, using simulations, studies three track reconstruction algorithms intended to be insta…
Triple-GEM detectors for the GE2/1 and ME0 stations of the endcap muon system for the Phase-2 upgrade of the CMS Experiment have been operated in a test beam to measure their efficiency and spatial resolution, together with a high spatial resolution triple- GEM tracker. A production module of GE2/1 detectors and a prototype ME0 detector show excellent local efficiency. A prototype detector with GEM foils employing random hole sectorization showed significant reduction of dead areas. The spatial resolution of the tracker has been measured and found close to the expected value of 75 μm.
As part of the Phase II upgrade program, the Compact Muon Solenoid (CMS) detector will incorporate a new timing layer designed to measure minimum ionizing particles (MIPs) with a time resolution of $\sim$30 ps. Precision timing will mitigate the impact of the challenging levels of pileup expected at the High Luminosity LHC. The time information assigned to each track will enable the use of 4D-vertexing which will render a 5-fold pile-up reduction, thus recovering the current conditions. Precision timing will also enable new time-based isolations and improved $b$-tagging algorithms. All of this…
The LHC machine is planning an upgrade program, which will smoothly bring the instantaneous luminosity to about $5-7.5\times10^{34}~\mathrm{cm}^{-2}\mathrm{s}^{-1}$ in 2028, to possibly reach an integrated luminosity of 3000-4500 fb$^{-1}$ by the end of 2039. This High-Luminosity LHC scenario, HL-LHC, will require a preparation program of the LHC detectors known as Phase-2 upgrade. The current CMS Outer Tracker, already running beyond design specifications, and the recently installed CMS Phase-1 Pixel Detector will not be able to survive the HL-LHC radiation conditions. Thus, CMS will need com…
The CMS Resistive Plate Chamber (RPC) system has been certified for 10 years of LHC operation. In the next years, during the High luminosity LHC (HL-LHC) phase, the LHC instantaneous luminosity will increase to a factor five more than the existing LHC luminosity. This will subject the present CMS RPC system to background rates and operating conditions much higher with respect to those for which the detectors have been designed. Those conditions could affect the detector properties and introduce nonrecoverable aging effects. A dedicated longevity test is set up in the CERN Gamma Irradiation Fac…
The LHC machine at CERN finished its first year of pp collisions at a center of mass energy of 7 TeV. While the commissioning to exploit its full potential is still ongoing, there are plans to upgrade its components to reach instantaneous luminosities beyond the initial design value after 2016. A corresponding upgrade of the innermost part of the CMS detector, the pixel detector, is needed. A full replacement of the pixel detector is planned in 2016. It will not only address limitations of the present system at higher data rates, but will aggressively lower the amount of material inside the fi…
CMS experiment will use Resistive Plate Chambers (RPCs) as dedicated muon trigger detectors. The first 24 RPCs for the barrel muon system of the CMS experiment have been assembled and tested. A brief description of the cosmic muon telescope used for the tests is given. The preliminary results for the chamber performance are presented.
In October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was successfully operated in the full barrel. More than 98% of the channels were operational during the exercise with typical detection efficiency of 90%. In this paper, the performance of the detector during these dedicated runs is reported.
High-Luminosity running at the LHC, which is planned for 2022 and beyond, will imply an order of magnitude increase in radiation levels and particle fluences with respect to the present LHC running conditions. The performance evolution of the CMS electromagnetic calorimeter (ECAL), comprising 75,848 scintillating lead tungstate crystals, indicates that an upgrade of its endcaps will be needed for HL-LHC running, to ensure an adequate performance. Results from LHC collision periods, beam tests and laboratory measurements of proton-irradiated crystals are combined to predict the performance of t…
A wealth of physics results have already been obtained from the LHC, due to the excellent performance of the collider and its experiments. Even more results are expected to be achievable in the phase of the high-luminosity LHC (HL-LHC). It is foreseen to deliver a ten times higher LHC design luminosity resulting in about 4000 fb-1 within ten years of operation. The upgrade of the LHC is driven by the prospect to observe and measure rare processes. High particle production rates and radiation doses result in a challenging environment for the collider experiments. The ATLAS and CMS experiments a…
The phase 1 upgrade of the CMS pixel detector has been designed to maintain the tracking performance at instantaneous luminosities of $2 \times 10^{34} \mathrm{~cm}^{-2} \mathrm{~s}^{-1}$. Both barrel and endcap disk systems now feature one extra layer (4 barrel layers and 3 endcap disks), and a digital readout that provides a large enough bandwidth to read out its 124M pixel channels (87.7 percent more pixels compared to the previous system). The backend control and readout systems have been upgraded accordingly from VME-based to micro-TCA-based ones. The detector is now also equipped with a …
The second LHC long shutdown period (LS2) is an important opportunity for the CMS Resistive Plate Chambers (RPC) to complete their consolidation and upgrade projects. The consolidation includes detector maintenance for gas tightness, HV (high voltage), LV (low voltage) and slow control operation. All services for the RPC Phase-2 upgrade, namely RE3/1 and RE4/1, were anticipated for installation to LS2. This paper summarises the RPC system maintenance and upgrade activities.
The High-Luminosity LHC (HL-LHC) will usher in a new era in high-energy physics. The HL-LHC experimental conditions entail an instantaneous luminosity of up to $7.5 \times 10^{34}$ cm$^{-2}$ s$^{-1}$ and up to 200 simultaneous collisions per bunch crossing (pileup). To cope with those conditions, the CMS detector will undergo a series of improvements, in what is known as the Phase-2 upgrade. In particular, the upgrade of the Data Acquisition and of the High-Level Trigger (DAQ-HLT) will have to address a much higher event rate and more complex events. In this paper, we will discuss the aspects …
At the High Luminosity LHC (HL-LHC), the CMS experiment will face a harsh environment with a high instantaneous luminosity up to 7x10$^{34}$/cm$^2$/s corresponding to an average of 140-200 multiple proton-proton collisions per bunch crossing. The main goal of the CMS Level 1 (L1) trigger upgrade for the HL-LHC is to maintain trigger thresholds that are as low as possible and comparable to those currently in use at the LHC, and to possibly include new triggers that were not feasible at the LHC. This will be achieved by upgrading the detector readout electronics, to allow a much larger L1 trigge…
The CMS collaboration is building a new inner tracking pixel detector for the High-Luminosity LHC. Each pixel readout chip will be controlled with a single serial input stream at 160 Mbps and will send out data via four current mode logic (CML) 1.28 Gbps outputs. The readout chips will be grouped in modules and connected with up to 1.6 meters long low-mass electrical links to Low-Power Gigabit Transceivers (lpGBT) and Versatile Link PLUS Transceiver (VTRx+) modules that send the data optically to off-detector electronics at 10 Gbps. The characterization of these components and system tests of …
Analysis of the CMS data and the simulation prediction based on these results indicate that the performance of the current scintillators in the CMS Hadron Endcap Calorimeter (HE) tiles will degrade dramatically in the High Luminosity LHC (HL-LHC) era. In order to continue the physics program in this region, the HE tiles will need to be replaced. The new tiles should have comparable/improved performance, be radiation hard, reliable and robust.
The current CMS silicon pixel detector as the innermost component of the CMS experiment is performing well at LHC design luminosity, but would be subject to severe inefficiencies at LHC peak luminosities of 2x10e34 cm^-2 s^-1. Therefore, an upgrade of the CMS pixel detector is planned, including a new readout chip. The chip design comprises additional on-chip buffer cells as well as high-speed data links and low-threshold comparators in the pixel cells. With these changes the upgraded pixel detector will be able to maintain or even improve the efficiency of the current detector at the increase…
As part of the Compact Muon Solenoid experiment Phase-II upgrade program, new Resistive Plate Chambers will be installed in the forward region. High background conditions are expected in this region during the high-luminosity phase of the Large Hadron Collider, therefore an improved RPC design has been proposed with a new front-end electronics to sustain a higher rate capability and better time resolution. A new technology is used in the front-end electronics resulting in very low achievable thresholds of the order of several fC. Crucial in the design of the improved RPC is the capability of a…
Between 2025 and 2027, some essential components of the CMS (Compact Muon Solenoid) detector - most notably the tracker and the calorimeter endcap - will be upgraded to prepare for HL-LHC (High Luminosity Large Hadron Collider) conditions. The upgraded CMS Outer Tracker and parts of the new CMS High Granularity Calorimeter (HGCAL) will encompass over $50{,}000$ new silicon sensors covering a total area of about $800\,\text{m}^{2}$. The sensor series production requires a dedicated strategy to monitor the quality and stability of the production process. The strategy is based on a test structure…
Hybrid silicon pixel detectors are currently used in the innermost tracking system of the Compact Muon Solenoid (CMS) experiment. Radiation tolerance up to fluences expected for a few years of running of the Large Hadron Collider (LHC) has already been proved, although some degradation of the part of the silicon detector closer to the interaction point is expected. During the LHC upgrade phases, the level of dose foreseen for the silicon pixel detector will be much higher. To face this aspect, dedicated irradiation tests with fluences above $\mathcal{O}(10^{15})$ n$_{\textrm{eq}}$/cm$^2$ have …
The electromagnetic ealorimeter (ECAL) of the CMS detector has played an important role in the physics program of the experiment, delivering outstanding performance throughout data taking. The High-Luminosity LHC will pose new challenges. The four to five-fold increase of the number of interactions per bunch crossing will require superior time resolution and noise rejection capabilities. For these reasons the electronics readout has been completely redesigned. A dual gain trans-impedance amplifier and an ASIC providing two 160 MHz ADC channels, gain selection, and data compression will be used…
The CMS detector at the LHC requires a major upgrade to cope with the higher instantaneous luminosity and the elevated radiation levels. The active media of the forward backing hadron calorimeters is projected to be radiation-hard, high light yield scintillation materials or similar alternatives. In this context, we have studied various radiation-hard scintillating materials such as Polyethylene Terephthalate (PET), Polyethylene Naphthalate (PEN), High Efficiency Mirror (HEM) and quartz plates with various coatings. The quartz plates are pure Cerenkov radiators and their radiation hardness has…
In preparation for the High Luminosity LHC, the entire tracker detector of the CMS experiment will be exchanged as part of the Phase-2 Upgrade. The new Outer Tracker will comprise approximately 13,000 silicon sensor modules, of which 7608 are "2S modules" consisting of two parallel mounted silicon strip sensors, and 5592 are "PS modules" consisting of one pixel and one strip sensor in a single module. These modules provide tracking information to the Level 1 trigger by correlating the hit information of both sensor layers, allowing discrimination of particle tracks by their transverse momentum…
The present Compact Muon Solenoid silicon pixel tracking system has been designed for a peak luminosity of 1034cm-2s-1 and total dose corresponding to two years of the Large Hadron Collider (LHC) operation. With the steady increase of the luminosity expected at the LHC, a new pixel detector with four barrel layers and three endcap disks is being designed. We will present the key points of the design: the new geometry, which minimizes the material budget and increases the tracking points, and the development of a fast digital readout architecture, which ensures readout efficiency even at high r…
This White Paper outlines a proposal for an upgraded forward region to extend CMS lepton (e, mu) and photon physics reach out to 2.2<eta<5 for LHC and SLHC, which also provides better performance for the existing or new forward hadron calorimetry for jet energy and (eta, phi) measurements, especially under pileup/overlaps at high lumi, as LHC luminosity, energy and radiation damage increases.
The PhaseII Upgrades of CMS are being planned for the High Luminosity LHC (HL-LHC) era when the mean number of interactions per beam crossing ("in-time pileup") is expected to reach ~140-200. The potential backgrounds arising from mis-associated jets and photon showers, for example, during event reconstruction could be reduced if physics objects are tagged with an "event time". This tag is fully complementary to the "event vertex" which is already commonly used to reduce mis-reconstruction. Since the tracking vertex resolution is typically ~10^{-3} (50 micron/4.8cm) of the rms vertex distribut…
The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. A report is given on the performance o…
During the high-luminosity phase of the LHC (HL-LHC), planned to start around 2027, the accelerator is expected to deliver an instantaneous peak luminosity of up to $7.5\times10^{34}$ cm$^{-2}$s$^{-1}$. A total integrated luminosity of $3000$ or even $4000$~fb$^{-1}$ is foreseen to be delivered to the general purpose detectors ATLAS and CMS over a decade, thereby increasing the discovery potential of the LHC experiments significantly. The CMS detector will undergo a major upgrade for the HL-LHC, with entirely new tracking detectors consisting of an Outer Tracker and Inner Tracker. However, the…
CMS experiment constructed the fourth Resistive Plate Chamber (RPC) trigger station composed of 144 RPCs to enhance the high momentum muon trigger efficiency at both endcap regions. All new CMS endcap RPC gaps are produced in accordance with QA and QC at the Korea Detector Laboratory (KODEL) in Korea. All qualified gaps have been delivered to three assembly sites: CERN in Switzerland, BARC in India, and Ghent University in Belgium for the RPC detector assembly. In this paper, we present the detailed procedures used in the production of RPC gaps adopted for the CMS upgrade.
The second phase of the T2K experiment is expected to start data taking in autumn 2022. An upgrade of the Near Detector (ND280) is under development and includes the construction of two new Time Projection Chambers called High-Angle TPC (HA-TPC). The two endplates of these TPCs will be paved with eight Micromegas type charge readout modules. The Micromegas detector charge amplification structure uses a resistive anode to spread the charges over several pads to improve the space point resolution. This innovative technique is combined with the bulk-Micromegas technology to compose the "Encapsula…
The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for future colliders. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimeters. It features unprecedented transverse and longitudinal segmentation for both electromagnetic (ECAL) and hadronic (HCAL) compartments. This will facilitate particle-flow calorimetry, where the fine …
Over the next ten years, the physics reach of the Large Hadron Collider (LHC) at the European Organization for Nuclear Research (CERN) will be greatly extended through increases in the instantaneous luminosity of the accelerator and large increases in the amount of collected data. Due to changes in the way Moore's Law computing performance gains have been realized in the past decade, an aggressive program of R&D is needed to ensure that the computing capability of CMS will be up to the task of collecting and analyzing this data.
The Resistive Plate Chamber (RPC) muon subsystem contributes significantly to the formation of the trigger decision and reconstruction of the muon trajectory parameters. Simulation of the RPC response is a crucial part of the entire CMS Monte Carlo software and directly influences the final physical results. An algorithm based on the parametrization of RPC efficiency, noise, cluster size and timing for every strip has been developed. Experimental data obtained from cosmic and proton-proton collisions at $\sqrt{s}=7$ TeV have been used for determination of the parameters. A dedicated validation…
During the third long shutdown of the CERN Large Hadron Collider, the CMS Detector will undergo a major upgrade to prepare for Phase-2 of the CMS physics program, starting around 2026. The upgraded CMS detector will be read out at an unprecedented data rate of up to 50 Tb/s with an event rate of 750 kHz, selected by the level-1 hardware trigger, and an average event size of 7.4 MB. Complete events will be analyzed by the High-Level Trigger (HLT) using software algorithms running on standard processing nodes, potentially augmented with hardware accelerators. Selected events will be stored perma…
The CMS Level-1 calorimeter trigger is being upgraded in two stages to maintain performance as the LHC increases pile-up and instantaneous luminosity in its second run. In the first stage, improved algorithms including event-by-event pile-up corrections are used. New algorithms for heavy ion running have also been developed. In the second stage, higher granularity inputs and a time-multiplexed approach allow for improved position and energy resolution. Data processing in both stages of the upgrade is performed with new, Xilinx Virtex-7 based AMC cards.
The CMS pixel detector has been designed for a peak luminosity of 10^34cm-2s-1 and a total dose corresponding to 2 years of LHC operation at a radius of 4 cm from the interaction region. Parts of the pixel detector will have to be replaced until 2015. The detector performance will be degraded for two reasons: radiation damage of the innermost layers and the planned increase of the LHC peak luminosity by a factor of 2-3. Based on the experience in planning, constructing and commissioning of the present pixel detector, we intend to upgrade the whole pixel detector in 2015. The main focus is on l…
CMS-HF Calorimeters have been undergoing a major upgrade for the last couple of years to alleviate the problems encountered during Run I, especially in the PMT and the readout systems. In this poster, the problems caused by the old PMTs installed in the detectors and their solutions will be explained. Initially, regular PMTs with thicker windows, causing large Cherenkov radiation, were used. Instead of the light coming through the fibers from the detector, stray muons passing through the PMT itself produce Cherenkov radiation in the PMT window, resulting in erroneously large signals. Usually, …
We present an FPGA-based readout chip emulator board for the CMS Endcap Timing Layer (ETL) detector upgrade. The emulator board uses an Intel Cyclone 10 GX FPGA to emulate the digital functions of four Endcap Layer Readout Chips (ETROCs). Based on the actual ETROC design, the firmware is implemented and verified. The emulator board is being used for the ETROC digital design verification and system development.
An efficient and precise reconstruction of charged-particle tracks is crucial for the overall performance of the CMS experiment. During Run 2 of LHC, significant upgrades were made to the track reconstruction algorithms in order to accommodate for the high pileup environment and the installation of an upgraded pixel detector in 2017. This paper provides an overview of the iterative track reconstruction algorithm used in CMS during Run 2 and of the performance measured both with simulated and collision data. Developments are ongoing to further improve track reconstruction in Run 3, especially f…
The CMS experiment will include a pixel detector for pattern recognition and vertexing. It will consist of three barrel layers and two endcaps on each side, providing three space-points up to a pseudoraditity of 2.1. Taking into account the expected limitations of its performance in the LHC environment an 8-9 layer pixel detector for an upgraded LHC is discussed.
T2K is a long baseline neutrino experiment that has been operating since 2009 providing some of the world-wide leading measurements for neutrino oscillation parameters. An upgrade for the Near Detector, ND280, of T2K has been proposed. It includes the installation of two new Time Projection Chambers (TPC) based on a new read-out technology: the resistive anode MicroMegas (RMM). This technology is expected to reduce the number of electronic channels while maintaining or improving the current ND280 TPCs' bulk MicroMegas perfomance. A series of tests have been performed and further studies are on…
The high-luminosity phase of the Large Hadron Collider (HL-LHC) will result in ten times higher particle background than measured during the first phase of LHC operation. In order to fully exploit the highly-demanding operating conditions during HL-LHC, the Compact Muon Solenoid (CMS) Collaboration will use Gas Electron Multiplier (GEM) detector technology. The technology will be integrated into the innermost region of the forward muon spectrometer of CMS as an additional muon station called GE11. The primary purpose of this auxiliary station is to help in muon reconstruction and to control le…
The Muon Upgrade Phase II of the Compact Muon Solenoid (CMS) aims to guarantee the optimal conditions of the present system and extend the $η$ coverage to ensure a reliable system for the High Luminosity Large Hadron Collider (HL-LHC) period. The Resistive Plate Chambers (RPCs) system will upgrade the off-detector electronics (called link system) of the chambers currently installed chambers and place improved RPCs (iRPCs) to cover the high pseudo$-$rapidity region, a challenging region for muon reconstruction in terms of background and momentum resolution. In order to find the best option for …
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| η|<2.4$ endcap region. With a sufficiently fine segmentation GEMs can provide precision tracking as well as fast trigger information. The main objective is to contribute to the improvement of the CMS muon trigger. The construction of large-area GEM detectors is challenging both from the technological and production aspects. In view of the CMS upgrade we have designed and built the largest full-size Triple-GEM muon detec…