Performance of the diamond-based beam-loss monitor system of Belle II
S. Bacher, G. Bassi, L. Bosisio, G. Cautero, P. Cristaudo, M. Dorigo, A. Gabrielli, D. Giuressi, K. Hara, Y. Jin, C. La Licata, L. Lanceri, R. Manfredi, H. Naka… 展开作者
S. Bacher, G. Bassi, L. Bosisio, G. Cautero, P. Cristaudo, M. Dorigo, A. Gabrielli, D. Giuressi, K. Hara, Y. Jin, C. La Licata, L. Lanceri, R. Manfredi, H. Nakayama, K. R. Nakamura, A. Natochii, A. Paladino, G. Rizzo, L. Vitale, H. Yin
We designed, constructed and have been operating a system based on single-crystal synthetic diamond sensors, to monitor the beam losses at the interaction region of the SuperKEKB asymmetric-energy electron-positron collider. The system records the radiation dose-rates in positions close to the inner detectors of the Belle II experiment, and protects both the detector and accelerator components against destructive beam losses, by participating in the beam-abort system. It also provides complementary information for the dedicated studies of beam-related backgrounds. We describe the performance of the system during the commissioning of the accelerator and during the first physics data taking.
The Belle II detector is currently under construction at the SuperKEKB electron-positron high-luminosity collider, that will provide an instantaneous luminosity 40 times higher than that of KEKB. There- fore the Belle-II VerteX Detector (VXD) will operate in a very harsh environment. A radiation monitoring and beam abort system is needed to safely operate the VXD detector in these conditions. This system is based on 20 single crystal CVD diamond sensors placed in 20 key positions in the vicinity of the VXD and interaction region. In this contribution we describe the system design and we presen…
The Belle II experiment will be at the forefront of indirect searches for non-Standard-Model physics using billions of heavy quarks and $τ$ leptons produced in high-intensity 10 GeV electron-positron collisions from the SuperKEKB collider. The intense beams needed to achieve the required precisions are associated with high beam-background radiation that may damage the inner detectors. A dedicated radiation-monitoring and beam-abort system, based on artificial diamond sensors, ensures protection and safe data taking conditions. I briefly outline the system and illustrate the operational experie…
The Belle II experiment has just started, searching for physics beyond the Standard Model in $B$, charm and $τ$ decays using data with the integrated luminosity goal of $50 ~\mathrm{ab}^{-1}$. Before the physics run with full detector system being installed, Belle II Phase 2 run is on-going at the time of the conference, until July 2018. In this presentation, we describe the environmental monitoring system with an emphasis on the software tools to help the experts and the non-expert shifters who operate the experiment. The monitoring tools are prepared on the control room especially for the sh…
Artificially-grown diamond crystals have unique properties that make them suitable as solid-state particle detectors and dosimeters in high-radiation environments. We have been using sensors based on single-crystal diamond grown by chemical vapour deposition for dosimetry and beam-loss monitoring at the SuperKEKB collider. Here we describe the assembly and the suite of test and calibration procedures adopted to characterise the diamond-based detectors of this monitoring system. We report the results obtained on 28 detectors and assess the stability and uniformity of response of these devices.
To prevent excessive radiation damage to its Silicon Vertex Tracker, the BaBar experiment at SLAC uses a radiation monitoring and protection system that triggers a beam abort whenever radiation levels are anomalously high. The existing system, which employs large area Si PIN diodes as radiation sensors, has become increasingly difficult to operate due to radiation damage. We have studied CVD diamond sensors as a potential alternative for these silicon sensors. Two diamond sensors have been routinely used since their installation in the Vertex Tracker in August 2002. The experience with these s…
The Belle-II VerteX Detector (VXD) is a 6 layers silicon tracker device that will cope with an unprecedented luminosity of 8 x 10^35 cm-2 s-1 achievable by the new SuperKEKB e+e- collider, now under commissioning at the KEK laboratory (Tsukuba, Japan). A radiation monitoring and beam abort system has been developed based on single-crystal s-CVD diamond sensors. The sensors will be placed in 20 key positions in the vicinity of the interaction region. The severe space limitations require a remote readout of the sensors. In this contribution we present the system design, along with the sensor cha…
Optimization of blade type X-ray Beam Position Monitors (XBPM) was performed for NSLS-II undulator IVU20. Blade material, configuration and operation principle was analyzed to improve XBPM performance. Optimization is based on calculation of the XBPM signal spatial distribution. Along with standard photoemission blades, Diamond Detector Blade (DDB) was analyzed as XBPM signal source. Analyses revealed, that Diamond Detector Blade XBPM would allow overcoming drawbacks of the photoemission type XBPMs.
Diamonds offer radiation hard sensors, which can be used directly in primary beams. Here we report on the use of a polycrystalline CVD diamond strip sensor as beam monitor of heavy ion beams with up to 2.10^9 lead ions per bunch. The strips allow for a determination of the transverse beam profile to a fraction of the pitch of the strips, while the timing information yields the longitudinal bunch length with a resolution of the order of a few mm.
We present the design and initial prototype results of a pixellized proton beam profile monitor for the COMET experiment at J-PARC. The goal of COMET is to look for charged lepton flavor violation by direct muon to electron conversion at a sensitivity of $0^{-19}$. An 8 GeV proton beam pulsed at 100 ns with $10^{10}$ protons/s will be used to create muons through pion production and decay. In the final experiment, the proton flux will be raised to $10^{14}$ protons/sec to increase the sensitivity. These requirements of harsh radiation tolerance and fast readout make diamond a good choice for c…
With the commissioning of the LHC expected in 2009, and the LHC upgrades expected in 2012, ATLAS and CMS are planning for detector upgrades for their innermost layers requiring radiation hard technologies. Chemical Vapor Deposition (CVD) diamond has been used extensively in beam conditions monitors as the innermost detectors in the highest radiation areas of BaBar, Belle and CDF and is now planned for all LHC experiments. This material is now being considered as an alternate sensor for use very close to the interaction region of the super LHC where the most extreme radiation conditions will ex…
The Belle II experiment is designed to collect 50 times more data than its predecessor. For a smooth collection of high-quality data, a robust and automated data transport and processing pipeline has been established. We describe the basic software components employed by the high level trigger. It performs a reconstruction of all events using the same algorithms as offline, classifies the events according to physics criteria, and provides monitoring information. The improved system described in this paper has been deployed successfully since 2019.
The Belle II experiment at the SuperKEKB $e^{+}e^{-}$ collider in KEK, Japan, started physics data-taking with a complete detector from early 2019 with the primary physics goal of probing new physics in heavy quark and lepton decays. An online trigger system is indispensable for the Belle II experiment to reduce the beam background events associated with high electron and positron beam currents without sacrificing the target physics-oriented events. During the Belle II operation upon beam collision, the trigger system must be consistently controlled and its status must be carefully monitored i…
The beam condition monitoring leakage (BCML) system is a beam monitoring device in the compact muon solenoid (CMS) experiment at the large hadron collider (LHC). As detectors 32 poly-crystalline (pCVD) diamond sensors are positioned in rings around the beam pipe. Here, high particle rates occur from the colliding beams scattering particles outside the beam pipe. These particles cause defects, which act as traps for the ionization, thus reducing the charge collection efficiency (CCE). However, the loss in CCE was much more severe than expected from low rate laboratory measurements and simulatio…
pCVD diamond sensors are regularly used as beam loss monitors in accelerators by measuring the ionization of the lost particles. In the past these beam loss monitors showed sudden increases in the dark leakage current without beam losses and these erratic leakage currents were found to decrease, if magnetic fields were present. Here we report on a systematic study of leakage currents inside a magnetic field. The decrease of erratic currents in a magnetic field was confirmed. On the contrary, diamonds without erratic currents showed an increase of the leakage current in a magnetic field perpend…
Diamond has been developed as a material for the detection of charged particles by ionization. Its radiation hardness makes it an attractive material for detectors operated in a harsh radiation environment e.g. close to a particle beam as is the case for beam monitoring and for pixel vertex detectors. Poly-crystalline chemical vapor deposition (CVD) diamond has been studied as strip and pixel detectors so far. We report on a first-time characterization of a single-crystal diamond pixel detector in a 100 GeV particle beam at CERN. The detectors are made from irregularly shaped single crystal se…
Diamond sensors (DS) are widely used as solid-state particle detectors, beam loss monitors, and dosimeters in high-radiation environments, e.g., particle colliders. We have calibrated our DS with steady $β$- and X-radiation, spanning a dose rate in the range 0.1-100 mGy/s. Here, we report the first systematic characterization of transient responses of DS to collimated, sub-picosecond, 1 GeV electron bunches. These bunches, possessing a charge ranging from tens to hundreds of pC and a size from tens of microns to millimeters, are suitably provided by the FERMI electron linac in Trieste, Italy. …
In the context of online ion range verification in particle therapy, the CLaRyS collaboration is developing Prompt-Gamma (PG) detection systems. The originality in the CLaRyS approach is to use a beam-tagging hodoscope in coincidence with the gamma detectors to provide both temporal and spatial information of the incoming ions. The ion range sensitivity of such PG detection systems could be improved by detecting single ions with a 100 ps ($σ$) time resolution, through a quality assurance procedure at low beam intensity at the beginning of the treatment session. This work presents the investiga…
The BCML system is a beam monitoring device in the CMS experiment at the LHC. As detectors poly-crystalline diamond sensors are used. Here high particle rates occur from the colliding beams scattering particles outside the beam pipe. These particles cause defects, which act as traps for the ionization, thus reducing the CCE. However, the loss in CCE was much more severe than expected. The reason why in real experiments the CCE is so much worse than in laboratory experiments is related to the rate of incident particles. At high particle rates the trapping rate of the ionization is so high compa…
This article introduces a design of a Low Noise Amplifier (LNA), for the field of diamond particle detectors. This amplifier is described from simulation to measurements, which include pulses from α particles detection. In hadron therapy, with high-frequency pulsed particle beams, the diamond detector is a promising candidate for beam monitoring and time-stamping, with prerequisite of fast electronics. The LNA is designed with surface mounted components and RF layout techniques to control costs and to allow timing performance suitable for sub-nanosecond edges of pulses. Also this amplifier off…
The CMS Beam Conditions and Radiation Monitoring System, BRM, will support beam tuning, protect the CMS detector from adverse beam conditions, and measure the accumulated dose close to or inside all sub-detectors. It is composed of different sub-systems measuring either the particle flux near the beam pipe with time resolution between nano- and microseconds or the integrated dose over longer time intervals. This paper presents the Fast Beam Conditions Monitor, BCM1F, which is designed for fast flux monitoring measuring both beam halo and collision products. BCM1F is located inside the CMS pixe…
The LHCb experiment at the European Organization for Nuclear Research (CERN) is dedicated to precision measurements of CP violation and rare decays of B hadrons. Its most sensitive components are protected by means of a Beam Conditions Monitor (BCM), based on polycrystalline CVD diamond sensors. Its configuration, operation and decision logics to issue or remove the beam permit signal for the Large Hadron Collider (LHC) are described in this paper.
The Beam Conditions and Radiation Monitoring System, BRM, is implemented in CMS to protect the detector and provide an interface to the LHC. Seven sub-systems monitor beam conditions and the radiation level inside the detector on different time scales. They detect adverse beam conditions, facilitate beam tuning close to CMS, and measure the doses accumulated in different detector components. Data are taken and analysed independently of the CMS data acquisition, displayed in the control room, and provide inputs to the trigger system and the LHC operators. In case of beam conditions dangerous to…
Beam commissioning of the SuperKEKB collider began in 2016. The Beam Exorcism for A STable experiment II (BEAST II) project is particularly designed to measure the beam backgrounds around the interaction point of the SuperKEKB collider for the Belle II experiment. We develop a system using bismuth germanium oxide (BGO) crystals with optical fibers connecting to a multianode photomultiplier tube (MAPMT) and a field-programmable gate array (FPGA) embedded readout board for monitoring the real-time beam backgrounds in BEAST II. The overall radiation sensitivity of this system is estimated to be $…
This article reports the first operation of a double-sided CMOS pixelated ladder in a collider experiment, namely in the inner tracker volume of the Belle II experiment during the Phase 2 run of the SuperKEKB collider. Design and integration of the detector system in the experiment interaction region is first described. The two modules operated almost continuously during slightly more than four months, recording data for the monitoring of the hit rate close to beams. Details of the off-line data analysis are provided and a method to estimate particle momentum from the 2 hits measured per cross…
The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. A report is given on the performance o…
The widespread diffusion of precision radiotherapy techniques, geared toward the release of larger dose gradients in shorter time frames, is leading to new challenges in dosimetry. Accurate dose measurements are essential to check for beam anomalies and inaccuracies to ensure treatment efficacy and patient safety during radiotherapy. This work describes the main features of a diamond dosimeter coupled to an extremely compact front-end electronics. The detection system was tested under the X-ray pulses generated by a medical LINAC for both the 6 MV and the 18 MV accelerating voltages. Located i…
In view of the implementation of beam-monitoring sensors for CERN's Large Hadron Collider (LHC), and also in order to validate Thermoluminescence Detectors as a versatile tool to measure ionizing radiation doses in mixed fields at hadron colliders such as the LHC, chemical vapor deposition diamond sensors have been evaluated and calibrated at CERN's Proton Synchrotron accelerator. Special attention was paid to understanding whether lithiumfluoride thermoluminescence detectors are suitable as measuring devices in these radiation fields.
We describe operation of the CESR-TA vertical beam size monitor (xBSM) with $e^\pm$ beams with $E_{\rm b}$=4 GeV. The xBSM measures vertical beam size by imaging synchrotron radiation x-rays through an optical element onto a detector array of 32 InGaAs photodiodes with 50 $μ$m pitch. The device has previously been successfully used to measure vertical beam sizes of 10-100 $μ$m on a bunch-by-bunch, turn-by-turn basis at $e^\pm$ beam energies of $\sim$2 GeV and source magnetic fields below 2.8 kG, for which the detector required calibration for incident x-rays of 1-5 keV. At $E_{\rm b}=4.0$ GeV …
Extremely radiation hard sensors are needed in particle physics experiments to instrument the region near the beam pipe. Examples are beam halo and beam loss monitors at the Large Hadron Collider, FLASH or XFEL. Currently artificial diamond sensors are widely used. In this paper single crystal sapphire sensors are considered as a promising alternative. Industrially grown sapphire wafers are available in large sizes, are of low cost and, like diamond sensors, can be operated without cooling. Here we present results of an irradiation study done with sapphire sensors in a high intensity low energ…
In ion cancer therapy, high-intensity ion beams are used to treat tumors by taking advantage of the Bragg-Peak. Typical ion therapy centers use particle rates up to $10^{10}$ ions/second for treatment. On the other hand, such intensities are often too high when using these beamlines for particle physics experiments or as a test-beam environment in general. The project presented here aims to develop a beam position and intensity monitor, to cover a wide intensity range from a few Hz up to GHz rates, as used in clinical settings. Silicon carbide (SiC) is an attractive detector material for this …
CBM T0 Detector Performance Study with Light Ions (4He, 12C) and the DOGMA Readout System
Technische Universität Darmstadt(达姆施塔特工业大学);Austrian Academy of Sciences, Marietta-Blau-Institut for Particle Physics(奥地利科学院玛丽埃塔·布劳粒子物理研究所);GSI Helmholtzzentrum für Schwerionenforschung GmbH(德国重离子研究中心);Helmholtz Forschungsakademie Hessen für FAIR(黑森FAIR亥姆霍兹研究学院);TU Wien, Atominstitut(维也纳工业大学原子能研究所)