arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2101.02493physics.optics
收藏

1550 nm线性和有源光纤腔中相移腔衰荡光谱传感应用

Phase shift-cavity ring down spectroscopy in linear and active fiber cavities for sensing applications at 1550 nm

Ubaid Ullah, M. Imran Cheema

摘要:

由于广泛可用的现成组件,在1550 nm处的液相传感应用是非常期望的。通常,1550 nm处的液体会引起高吸收损失,这限制了整个传感器的灵敏度和检测限。一种解决方案是结合腔衰荡光谱使用有源光纤环来克服这些吸收损耗。然而,光纤环路内的放大器受到固有增益波动的影响,这限制了传感系统的整体性能。在这里,我们提供了一种新的传感器,使用波长扫描相移腔衰荡光谱(PS-CRDS)结合线性有源光纤腔,可能提供比传统的光纤环传感器更灵敏的解决方案。我们使用一个锥形光纤作为传感头内的主动腔由光纤布拉格光栅。我们推导出我们的系统的理论相移表达式,并使用有限元方法进行模拟,以确定最佳锥形光纤直径的葡萄糖传感在去离子水中。与未放大的系统相比,我们发现我们的放大系统可以通过放大器增益调谐将灵敏度提高14倍。我们还使用0-15.5~mM葡萄糖溶液进行实验测量,发现它们与我们的理论预测非常吻合。实验表明,该传感器的灵敏度为0.768~ $^o$ /mM(1164~ $^o$ /RIU),检测限为0.75~mM(4.5~ $\times$ ~10 $^{-4}$ ~RIU),无需任何温度稳定。我们预计,目前的工作将发现广泛的传感应用在光纤腔,环形谐振器,和其他微腔结构。

英文摘要:

Liquid phase sensing applications at 1550~nm are highly desirable due to widely available off-the-shelf components. Generally, liquids at 1550~nm induce a high absorption loss that limits the overall sensor's sensitivity and detection limit. One solution is to use an active fiber loop in conjunction with cavity ring down spectroscopy to overcome these absorption losses. However, the amplifier inside the fiber loop suffers from inherent gain fluctuations that limit the sensing system's overall performance. Here, we provide a novel sensor using the wavelength-scanned phase shift-cavity ring down spectroscopy (PS-CRDS) in conjunction with a linear active fiber cavity that potentially offers a more sensitive solution than traditional fiber loop sensors. We use a tapered fiber as a sensing head inside the active cavity built from fiber Bragg gratings. We derive a theoretical phase shift expression for our system and simulate it using the finite element method to determine optimum tapered fiber diameter for glucose sensing in DI water. Compared to a non-amplified system, we find that our amplified system can increase the sensitivity by fourteen times via the amplifier gain tuning. We also conduct experimental measurements using 0-15.5~mM glucose solutions and find them in excellent agreement with our theoretical predictions. Experimentally we obtain the sensor's sensitivity of 0.768~$^o$/mM (1164~$^o$/RIU) and detection limit of 0.75~mM ( 4.5~$\times$~10$^{-4}$~RIU) without any temperature stabilization in the system. We anticipate that the present work will find a wide range of sensing applications in fiber cavities, ring resonators, and other microcavity structures.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑