arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2009.14458eess.SYcs.SY
收藏

基于日前动态功率边界的DER信息无意识协调

DER Information Unaware Coordination via Day-ahead Dynamic Power Bounds

Thomas Navidi, Chloe Leblanc, Abbas El Gamal, Ram Rajagopal

摘要:

配电网中的可靠性和电压质量已经通过Transformer额定功率满足和电压管理资产控制的组合来实现。然而,为了在这种模式下保持可靠的运行,未来具有深度DER渗透的电网将需要昂贵的设备升级。这些升级可以通过明智地协调DER操作来减轻。早期的工作已经假设了分层控制架构,其中全局控制器(GC)使用详细的功率注入和DER数据以及DER所有者的目标的知识来确定本地控制器应该遵循的设定点,以便实现可靠且成本有效的电网操作。然而,拥有此类数据并假定了解对外关系报告所有者的目标往往是不可取或不可能的。在早期的工作中,一个2层DER协调架构,尽管不频繁的通信,以实现接近最佳性能的全球控制器。受这项工作的启发,本文提出了一个提前一天的协调计划,使用预测的功率分布范围,以产生提前一天的动态额定功率范围在每个Transformer。该方案的新特征包括:(i)GC仅知道过去的节点功率注入数据,并且不强加或知道DER所有者目标,(ii)我们使用确保可靠操作的边界来指导本地控制器,而不是设定点跟踪,以及(iii)除了存储之外,我们还考虑电动汽车(EV)充电。使用IEEE 123总线网络进行的仿真表明,在50%太阳能,50%电动汽车和10%存储渗透的情况下,不协调的方法几乎在所有86个Transformers上都发生了额定违规行为,并导致10倍的电压偏差,而我们的方法只发生了12次额定违规行为,并保持了与添加太阳能和电动汽车之前几乎相同的电压偏差。

英文摘要:

Reliability and voltage quality in distribution networks have been achieved via a combination of transformer power rating satisfaction and voltage management asset control. To maintain reliable operation under this paradigm, however, future grids with deep DER penetrations would require costly equipment upgrades. These upgrades can be mitigated via judicious coordination of DER operation. Earlier work has assumed a hierarchical control architecture in which a global controller (GC) uses detailed power injection and DER data and knowledge of DER owners' objectives to determine setpoints that local controllers should follow in order to achieve reliable and cost effective grid operation. Having such data and assuming knowledge of DER owners' objectives, however, are often not desirable or possible. In an earlier work, a 2-layer DER coordination architecture was shown to achieve close to optimal performance despite infrequent communication to a global controller. Motivated by this work, this paper proposes a day-ahead coordination scheme that uses forecasted power profile ranges to generate day-ahead dynamic power rating bounds at each transformer. Novel features of this scheme include: (i) the GC knows only past node power injection data and does not impose or know DER owner objectives, (ii) we use bounds that ensure reliable operation to guide the local controllers rather than setpoint tracking, and (iii) we consider electric vehicle (EV) charging in addition to storage. Simulations using the IEEE 123-bus network show that with 50% solar, 50% EVs and 10% storage penetrations, the uncoordinated approach incurs rating violations at nearly all 86 transformers and results in 10 times higher voltage deviation, while our approach incurs only 12 rating violations and maintains almost the same voltage deviations as before the addition of solar and EVs.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑