引力波探测器网络的自标定
Self-calibration of Networks of Gravitational Wave Detectors
摘要:
随着LIGO和Virgo的升级,改进校准系统以跟上预期的信噪比增强将是一项挑战。我们在这里探索一种校准方法,使用天文信号,即从致密天体双星inspiral信号,我们表明,它可以在原则上使校准在未来的引力波科学所需的子1\%的精度水平。我们展示了如何合奏这些瞬态事件可以用来测量校准误差的网络中的三个或更多的灵敏度仪器的单个探测器。与望远镜一样,使用探测到的事件对引力波探测器进行相对校准比绝对校准更容易实现,原则上,绝对校准仍然需要使用硬件方法对至少一个频率的探测器进行校准。我们提出的方法使用所谓的空流,即存在于具有三个或更多不同方向检测器的任何网络中的检测器输出的无信号线性组合。如果检测器输出中的信号幅度忠实于真实信号的幅度,则信号不会出现在零流中。频率相关的校准误差以及检测器之间的相对校准和定时误差在零流中留下残差。来自每个探测器的残留量取决于源方向。我们采用匹配滤波的方法来解决从残差中提取每个探测器的校准误差的问题。这需要线性组合足够数量的检测信号的滤波器输出,并且原则上它可以在足够长的观察运行中实现任何期望的精度。我们预计A+探测器网络,预计在5年内,可以采用这种方法来检查预期的硬件校准精度。
英文摘要:
As LIGO and Virgo are upgraded, improving calibration systems to keep pace with the anticipated signal-to-noise enhancements will be challenging. We explore here a calibration method that uses astronomical signals, namely inspiral signals from compact-object binaries, and we show that it can in principle enable calibration at the sub-1\% accuracy levels needed for future gravitational wave science. We show how ensembles of these transient events can be used to measure the calibration errors of individual detectors in a network of three or more comparably sensitive instruments. As with telescopes, relative calibration of gravitational-wave detectors using detected events is easier to achieve than absolute calibration, which in principle would still need to be done with a hardware method for at least one detector at one frequency. Our proposed method uses the so-called null streams, the signal-free linear combinations of the outputs of the detectors that exist in any network with three or more differently oriented detectors. Signals do not appear in the null stream if the signal amplitude in the detector output is faithful to that of the real signal. Frequency-dependent calibration errors and relative calibration and timing errors between detectors leave a residual in the null stream. The amount of residual from each detector depends on the source direction. We adapt the method of matched filtering to the problem of extracting the calibration error of each detector from this residual. This requires combining linearly the filter outputs of a sufficient number of detected signals, and in principle it can achieve any desired accuracy in a long enough observation run. We anticipate that A+ detector networks, expected in 5 years, could employ this method to check anticipated hardware calibration accuracies.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。