Dual-comb microscopy (DCM), an interesting imaging modality based on the optical-frequency-comb (OFC) mode and image pixel one-to-one correspondence, benefits from scan-less full-field imaging and simultaneous confocal amplitude and phase imaging. However, the two fully frequency-stabilized OFC sources requirement hampers DCM practicality due to the complexity and costs. Here, a bidirectional single-cavity dual-comb fiber laser (SCDCFL) is adopted as a DCM low-complexity OFC source. Computational image correction reduces the image blur caused by the SCDCFL residual timing jitter. Nanometer-order step surface profilometry with a 14.0 nm uncertainty highlights the image-corrected DCM effectiveness. The proposed method enhances the DCM versality and practicality.
We explore the possibility of applying physical phase plates (PPs) in combination with aberration-corrected transmission electron microscopy. Phase-contrast transfer characteristics are calculated and compared for a thin-film based Zernike PP, a hole-free (HF) or Volta PP and an electrostatic Zach PP, considering their phase-shifting properties in combination with partial spatial coherence. The effect of slightly converging illumination conditions, often used in high-resolution applications, on imaging with PPs is discussed. Experiments with an unheated Zernike PP applied to various nanomateri…
We report on the usage of ultrashort laser pulses in form of aberration-corrected Bessel-like beams for laser cutting of glass with bevels. Our approach foresees to incline the material's entrance surface with respect to the processing optics. The detailed analysis of phase distortions caused by the beam transition through the tilted glass surface allows to pre-compensate occurring aberrations using digital holography. We verify theoretical considerations by means of pump-probe microscopy and present high-quality edges in non-strengthened silicate glass.
A four-wave-mixing, frequency-comb-based, hyperspectral imaging technique that is spectrally precise, potentially rapid, and can in principle be applied to any material, is demonstrated in a near-diffraction-limited microscopy application.
Optical coherence tomography (OCT) has seen widespread success as an in vivo clinical diagnostic 3D imaging modality, impacting areas including ophthalmology, cardiology, and gastroenterology. Despite its many advantages, such as high sensitivity, speed, and depth penetration, OCT suffers from several shortcomings that ultimately limit its utility as a 3D microscopy tool, such as its pervasive coherent speckle noise and poor lateral resolution required to maintain millimeter-scale imaging depths. Here, we present 3D optical coherence refraction tomography (OCRT), a computational extension of O…
Scan-less full-field fluorescence-lifetime dual-comb microscopy using two-dimensional spectral mapping and frequency multiplexing of dual-optical-comb beats
Confocal and multiphoton microscopy are effective techniques to obtain high-contrast images of 2-D sections within bulk tissue. However, scattering limits their application to depths only up to ~1 millimeter. Multimode fibers make excellent ultrathin endoscopes that can penetrate deep inside the tissue with minimal damage. Here, we present Multiview Scattering Scanning Imaging Confocal (MUSSIC) Microscopy that enables high signal-to-noise ratio (SNR) imaging through a multimode fiber, hence combining the optical sectioning and resolution gain of confocal microscopy with the minimally invasive …
In this paper we describe the technical implementation of pump-probe cathodoluminescence microscopy (PP-CL), a novel technique for studying ultrafast dynamics in materials using combined excitation of electron and laser pulses. The PP-CL setup is based on a commercial scanning electron microscope combined with a femtosecond laser. Here we discuss the design, technical details, and characterization of the PP-CL setup. The luminescence emitted by the sample (either photoluminescence, cathodoluminescence or a combination of both) can be analyzed in terms of spectrum, temporal statistics, and freq…
Center of Advanced European Studies and Research (caesar)(欧洲高级研究中心 (caesar))
Aberrations limit scanning fluorescence microscopy when imaging in scattering materials such as biological tissue. Model-based approaches for adaptive optics take advantage of a computational model of the optical setup. Such models can be combined with the optimization techniques of machine learning frameworks to find aberration corrections, as was demonstrated for focusing a laser beam through aberrations onto a camera [arXiv:2007.13400]. Here, we extend this approach to two-photon scanning microscopy. The developed sensorless technique finds corrections for aberrations in scattering samples …