短回波时间弛豫增强MR光谱揭示了宽的低场共振

Short echo time relaxation-enhanced MR spectroscopy reveals broad downfield resonances

Sónia I. Gonçalves, Clémence Ligneul, Noam Shemesh

摘要:

目的:大多数磁共振波谱(MRS)脉冲序列依赖于含水饱和的宽带激发,通常集中在高场信号上。相比之下,包含许多潜在有用的共振的低场光谱通常不是目标,因为传统的水抑制技术通过交换间接饱和不稳定的质子。弛豫增强MRS(RE-MRS)使用频率选择性激发,同时主动避免大量水扰动,从而实现高质量的低场光谱。然而,由于其定位模块,RE-MRS通常需要非常长(通常>40 ms)的回波时间(TE),这不可避免地降低了灵敏度并过滤了较短的T2分量。在这里,我们通过结合RE-MRS和图像选择体内光谱(ISIS)定位(简称iRE-MRS)克服了这一限制,这反过来又允许非常短的TE(使用我们的硬件为5 ms)。方法:采用体外实验和9.4T大鼠脑内实验进行验证。结果:新的iRE-MRS方法在体模中得到验证,表现良好。当在体内大鼠大脑中短TE处研究低场光谱时,iRE-MRS提供了非常高的灵敏度;随后的低场光谱包括许多宽峰以及宽基线。所有的低场光谱峰高度衰减,增加TE以及通过应用水饱和度,虽然在不同程度上。TE之间的信号比率也不同,这表明交换率在低场信号之间是不同的。结论:短TE iRE 1H低场MRS为研究体内低场代谢物及其对健康和疾病过程的作用开辟了新的方向。

英文摘要:

Purpose: Most MR spectroscopy (MRS) pulse sequences rely on broadband excitation with water saturation and typically focus on upfield signals. By contrast, the downfield spectrum, which contains many potentially useful resonances, is typically not targeted because conventional water-suppressed techniques indirectly saturate the labile protons through exchange. Relaxation-enhanced MRS (RE-MRS) uses frequency-selective excitation while actively avoiding bulk water perturbation, thereby enabling high-quality downfield spectroscopy. However, RE-MRS typically requires very long (typically >40 ms) echo times (TEs) due to its localization module, which inevitably decreases sensitivity and filters shorter T2 components. Here, we overcome this limitation by combining RE-MRS and image selected in vivo spectroscopy (ISIS) localization, abbreviated iRE-MRS, which in turn allows very short TEs (5 ms using our hardware). Methods: Experiments were performed in vitro for validation as well as and in in vivo rat brains at 9.4T. Results: The new iRE-MRS methodology was validated in phantoms where good performance was noted. When the downfield spectrum was investigated at short TEs in in vivo rat brains, iRE-MRS provided very high sensitivity; the ensuing downfield spectra encompassed numerous broad peaks, as well as a broad baseline. All downfield spectral peaks were highly attenuated by increasing TEs as well as by applying water saturation, although to different extent. The signal ratios also varied between TEs, suggesting that exchange rates are different among the downfield signals. Conclusions: Short-TE iRE 1H downfield MRS opens new directions in the investigation of in vivo downfield metabolites and their role on healthy and disease processes.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑