7 T下人类白质多指数T2衰减的体内研究:UHF髓鞘水成像的意义
In vivo investigation of the multi-exponential T2 decay in human white matter at 7T: Implications for myelin water imaging at UHF
摘要:
使用梯度和自旋回波(GraSE)采集的多分量T2标测已成为3 T髓鞘水成像的标准。更高的磁场强度保证SNR益处,但面临比吸收率限制和缩短的T2时间。本研究调查了体内房室T2时间,并讨论了7 T下多分量T2标测的优势和挑战。我们在7 T下采集了7名健康成人的3D多回波GraSE数据,其中3名受试者也在3 T下扫描。由B+1不均匀性引起的刺激回波由扩展相位图(EPG)算法解释。我们使用计算的T2分布来确定识别不同水池的T2时间,并评估信号估计的信噪比和拟合噪声特性。我们比较了短T2馏分和T2性质的中间水池在3 T和7 T。翻转角标测证实EPG在7 T下准确确定了较大的不均匀性。多分量T2分析表明,与3 T相比,7 T下的T2时间缩短。在7 T下,拟合噪声和信噪比得到改善,但取决于B1均匀性。将最短T2降低至8 ms并将分离不同水室的T2阈值调整至20 ms,在7 T下产生符合3 T数据的短T2分数。在富含髓鞘的白质区域中,短T2分数在7 T时低于3 T,而在富含铁的结构中较高。由于在7 T下T2弛豫时间较短,因此需要调整T2室边界。较短的回波间隔将更好地采样快速衰减的信号,但将增加外周神经刺激。我们使用多回波3D-GraSE序列来表征在7 T下的多指数T2衰减。我们调整了T2参数,用于评估短T2分数。获得的7 T多分量T2图与3 T数据符合良好。
英文摘要:
Multicomponent T2-mapping using a gradient and spin-echo (GraSE) acquisition has become standard for myelin water imaging at 3T. Higher magnetic field strengths promise SNR benefits but face specific absorption rate limits and shortened T2 times. This study investigates compartmental T2 times in vivo and addresses advantages and challenges of multi-component T2-mapping at 7T. We acquired 3D multi-echo GraSE data in seven healthy adults at 7T, with three subjects scanned also at 3T. Stimulated echoes arising from B+1 inhomogeneities were accounted for by the extended phase graph (EPG) algorithm. We used the computed T2 distributions to determine T2 times that identify different water pools and assessed signal-to-noise and fit-to-noise characteristics of the signal estimation. We compared short T2 fractions and T2 properties of the intermediate water pool at 3T and 7T. Flip angle mapping confirmed that EPG accurately determined the larger inhomogeneity at 7T. Multi-component T2 analysis demonstrated shortened T2 times at 7T compared to 3T. Fit-to-noise and signal-to-noise ratios were improved at 7T but depended on B1 homogeneity. Lowering the shortest T2 to 8 ms and adjusting the T2 threshold that separates different water compartments to 20 ms, yielded short T2 fractions at 7T that conformed to 3T data. Short T2 fractions in myelin-rich white matter regions were lower at 7T than at 3T, and higher in iron-rich structures. Adjusting the T2 compartment boundaries was required due to the shorter T2 relaxation times at 7T. Shorter echo spacing would better sample the fast decaying signal but would increase peripheral nerve stimulation. We used a multi-echo 3D-GraSE sequence to characterize the multi-exponential T2 decay at 7T. We adapted T2 parameters for evaluation of the short T2 fraction. Obtained 7T multicomponent T2-maps were in good agreement with 3T data.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。