ATHENA硅孔光学系统的Geant4质量模型及其对质子软散射的影响
The Geant4 mass model of the ATHENA Silicon Pore Optics and its effect on soft proton scattering
摘要:
鉴于前所未有的有效面积、新的ATHENA硅孔光学(SPO)聚焦技术、动态且可变的L2环境(迄今为止尚未执行X射线任务),需要专门的Geant 4模拟活动来评估低能量质子的影响ATHENA镜面上的散射以及X射线探测器上诱导的剩余背景水平。Geant 4质量模型是作为欧空局AREMBES项目活动的一部分使用BoGEMMS框架建立的。SPO镜像模块行是质量模型的原子单位,允许通过20个独立运行来模拟整个结构,每行一个。得益于BoGEMMS配置文件,单孔、镜模块或整个SPO行都可以使用相同的Geant 4几何结构构建。Remizovich,在其弹性近似,和库仑单散射Geant 4模型中使用的单能质子束与一个单一的SPO孔的相互作用。第一种模型的散射效率几乎是后者的两倍,但对于这两种情况下,我们得到类似的极角和方位角分布,约70-75%的散射产生的单或双反射。模拟的等离子体片区域的软质子通量被用作输入的软质子漏斗的全SPO质量模型的模拟。ATHENA反射镜产生了比XMM-Newton EPIC探测器观测到的弱得多的软质子晕。到达焦平面(定义为15 cm半径)的剩余软质子通量比相同能量下进入反射镜的输入L2软质子总数低10^4倍,其速率与XMM EPIC-pn最强烈的软质子耀斑中观察到的速率相当或更高。
英文摘要:
Given the unprecedented effective area, the new ATHENA Silicon Pore Optics (SPO) focusing technology, the dynamic and variable L2 environment, where no X-ray mission has flown up to date, a dedicated Geant4 simulation campaign is needed to evaluate the impact of low energy protons scattering on the ATHENA mirror surface and the induced residual background level on its X-ray detectors. The Geant4 mass model is built as part of the ESA AREMBES project activities using the BoGEMMS framework. An SPO mirror module row is the atomic unit of the mass model, allowing the simulation of the full structure by means of 20 independent runs, one for each row. Thanks to the BoGEMMS configuration files, both single pores, mirror modules or the entire SPO row can be built with the same Geant4 geometry. Both Remizovich, in its elastic approximation, and Coulomb single scattering Geant4 models are used in the interaction of mono-energetic proton beams with a single SPO pore. The scattering efficiency for the first model is almost twice the efficiency obtained with the latter but for both cases we obtain similar polar and azimuthal angular distributions, with about 70-75% of scatterings generated by single or double reflections. The soft proton flux modelled for the plasma sheet region is used as input for the simulation of soft proton funnelling by the full SPO mass model. A much weaker soft proton vignetting than the one observed by XMM-Newton EPIC detectors is generated by ATHENA mirrors. The residual soft proton flux reaching the focal plane, defined as a 15 cm radius, is 10^4 times lower than the input L2 soft proton population entering the mirror, at the same energy, with rates comparable or higher than the ones observed in XMM EPIC-pn most intense soft proton flares.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。