arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 1801.03088physics.ins-detnucl-ex
收藏

GlueX实验用桶式电磁量热计的结构和性能

Construction and Performance of the Barrel Electromagnetic Calorimeter for the GlueX Experiment

Tegan Beattie, Ahmed Foda, Colleen Henschel, S Katsaganis, Shaun Krueger, George Lolos, Zisis Papandreou, E. L. Plummer, Irina Semenova, Andrei Semenov, Fernand… 展开作者

Tegan Beattie, Ahmed Foda, Colleen Henschel, S Katsaganis, Shaun Krueger, George Lolos, Zisis Papandreou, E. L. Plummer, Irina Semenova, Andrei Semenov, Fernando Barbosa, Eugene Chudakov, Mark Dalton, David Lawrence, Yi Qiang, Nicholas Sandoval, Elton Smith, Christopher Stanislav, Justin Stevens, Simon Taylor, Timothy Whitlatch, Benedikt Zihlmann, William Levine, William McGinley, Curtis Meyer, Michael Staib, Efstratios Anassontzis, Christina Kourkoumelis, Georgios Vasileiadis, George Voulgaris, William Brooks, Hayk Hakobyan, Sergey Kuleshov, R. Rojas, Christian Romero Vieyra, Orlando Soto Sandoval, Alam Toro Salas, Juan Vega Vergara, Matthew Shepherd

摘要:

桶式量热计是安装在杰斐逊实验室D厅的新光谱仪的一部分,用于GSTX实验。该热量计于2013年安装,2014年投入使用,自2015年初以来一直正常运行。本文描述了探测器配置、相关的蒙特卡罗模拟、校准和操作性能。量热计记录由多GeV光子束产生的带电和中性粒子沉积的时间和能量。它被构造为一个铅和放大纤维量热计和读出与3840大面积硅光电倍增器阵列。粒子在很宽的角度范围内撞击探测器,从90度到11.5度的垂直入射,这定义了一种在量热计中相当独特的几何形状。的量热计的响应已被测量在一个运行的实验,并执行预期低于2.5 GeV的电磁簇射。在1,GeV能量下,对$π^0$和$η$产生的典型角分布积分的能量分辨率为$σ_E/E$ = 5. 2%/ $\sqrt{E(\rm{GeV})} \oplus$ 3. 6%,时间分辨率为$σ$ = 1,150,ps.

英文摘要:

The barrel calorimeter is part of the new spectrometer installed in Hall D at Jefferson Lab for the GlueX experiment. The calorimeter was installed in 2013, commissioned in 2014 and has been operating routinely since early 2015. The detector configuration, associated Monte Carlo simulations, calibration and operational performance are described herein. The calorimeter records the time and energy deposited by charged and neutral particles created by a multi-GeV photon beam. It is constructed as a lead and scintillating-fiber calorimeter and read out with 3840 large-area silicon photomultiplier arrays. Particles impinge on the detector over a wide range of angles, from normal incidence at 90 degrees down to 11.5 degrees, which defines a geometry that is fairly unique among calorimeters. The response of the calorimeter has been measured during a running experiment and performs as expected for electromagnetic showers below 2.5 GeV. We characterize the performance of the BCAL using the energy resolution integrated over typical angular distributions for $π^0$ and $η$ production of $σ_E/E$=5.2\%/$\sqrt{E(\rm{GeV})} \oplus$ 3.6\% and a timing resolution of $σ$\,=\,150\,ps at 1\,GeV.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑