Fast X-ray detector system with simultaneous measurement of timing and energy for a single photon
T. Masuda, S. Okubo, H. Hara, T. Hiraki, S. Kitao, Y. Miyamoto, K. Okai, R. Ozaki, N. Sasao, M. Seto, S. Uetake, A. Yamaguchi, Y. Yoda, A. Yoshimi, K. Yoshimura
We developed a fast X-ray detector system for nuclear resonant scattering (NRS) experiments. Our system employs silicon avalanche photo-diode (Si-APD) as a fast X-ray sensor. The system is able to acquire both timing and energy of a single X-ray photon simultaneously in a high rate condition, $10^6$ counts per second for one Si-APD. The performance of the system was investigated in SPring-8, a synchrotron radiation facility in Japan. Good time resolution of \SI{120}{ps} (FWHM) was achieved with a slight tail distribution in the time spectrum by a level of $10^{-9}$ at 1 ns apart from the peak. Using this system, we successfully observed the NRS from the 26.27-keV level of mercury-201, which has a half-life of $630 \pm 50$ ps. We also demonstrated the reduction of background events caused by radioactive decays in a radioactive sample by discriminating photon energy.
We give a short compendium of the main ongoing detectors and concepts capable of performing accurate sub-100 ps timing at high particle fluxes and on large areas, through technologies based on gaseous media. We briefly discuss the state-of-the-art, technological limitations and prospects, and a new bizarre idea.
4H-Silicon Carbide, when considered as a material for the fabrication of Low Gain Avalanche Detectors for particle timing and position measurement, offers potential advantages over Silicon. We discuss an ongoing study of this material aimed at the fabrication and test of prototype fast timing sensors. This work is well aligned with technical directions identified in the recent Department of Energy study, Basic Research Needs for High Energy Physics Detector Research and Development.
In order to improve the time precision of detectors based on diamonds sensors we have built a detector with two scCVD layers connected in parallel to the same amplifier. This note describes the design and the first measurements of such a prototype performed on a particle beam at CERN. With this different configuration we have obtained an improvement on the timing precision of a factor of 1.6-1.7 with respect to a single layer scCVD diamond detector.
High precision timing, high rate calorimeters, and radiation resistance are becoming an important issue in particle physics especially in Energy and Intensity Frontiers. We discuss doped Zinc Oxide (ZnO:Ga or GZO; ZnO:X where X is Al, Cu or others) as a very fast scintillator and wavelength shifter (WLS), Total internal reflection films, and PMT capable of counting at 300 MHz with 10 ps timing precision, with superior radiation resistance.
This communication describes test beam results, focusing on detection efficiency and timing precision, of common float glass timing Resistive Plate Chambers (tRPCs) exposed to a $2.7$~GeV proton beam and operated at above ambient temperature in order to increase the count rate capability of the chambers, by exploiting the reduction in the resistivity of the glass electrodes. Results suggest that the count rate capability can be extended at least up to $1500~Hz/cm^2$ when the detector is operated at $40.6^{\circ}$C without noticeable loss of efficiency or timing precision degradation with value…
We analyze the origin of the intrinsic timing jitter in superconducting nanowire single photon detectors (SNSPDs) in terms of fluctuations in the latency of the detector response, which is determined by the microscopic physics of the photon detection process. We demonstrate that fluctuations in the physical parameters which determine the latency give rise to the intrinsic timing jitter. We develop a general description of latency by introducing the explicit time dependence of the internal detection efficiency. By considering the dynamic Fano fluctuations together with static spatial inhomogene…
The CMS-TOTEM Precision Proton Spectrometer (CT-PPS) is an approved project to add tracking and timing information at approximately $\pm$210~m from the interaction point around the CMS detector. It is designed to operate at high luminosity with up to 50 interactions per 25~ns bunch crossing to perform measurements of e.g. the quartic gauge couplings and search for rare exclusive processes. During 2016, CT-PPS took data in normal high-luminosity proton-proton LHC collisions. In the coming years, high radiation doses and large multiple-vertex interactions will represent difficult challenges that…
To meet high radiation challenge for detectors in future high-energy physics, a novel 3D 4H-SiC detector was investigated. SiC detectors could potentially operate in radiation harsh and room temperature environment because of its high thermal conductivity and high atomic displacement threshold energy. 3D structure, which decouples thickness and distance between electrodes, further improves timing performance and radiation hardness of the detector. We developed a simulation software - RASER (RAdiation SEmiconductoR) to simulate the time resolution of planar and 3D 4H-SiC detectors with differen…
A silicon 3D detector with a single cell of 50x50 um2 was produced and evaluated for timing applications. The measurements of time resolution were performed for 90Sr electrons with dedicated electronics used also for determining time resolution of Low Gain Avalanche Detectors (LGADs). The measurements were compared to those with LGADs and also simulations. The studies showed that the dominant contribution to the timing resolution comes from the time walk originating from different induced current shapes for hits over the cell area. This contribution decreases with higher bias voltages, lower t…
This work aims at the development of signal processing algorithms that can explore the potential of a PICOSEC-MicroMegas detector and offers the ability for online, precise timing. The PICOSEC-MicroMegas detector is a novel gaseous detector offering precise timing resolution in experimental measurements. The performance of the proposed signal processing algorithms is evaluated by a variety of tests using experimental data. The data used in the present research were accumulated during a Laser Beam Test at CEA/IRAMIS-SACLAY. We use two sets of experimental events: the SPE-set comprises single ph…
μRWELL-PICOSEC: Precision Timing with Resistive Micro-Well Detector
Thomas Jefferson National Accelerator Facility(托马斯·杰斐逊国家加速器设施);IRFU, CEA, Université Paris-Saclay(IRFU, 法国原子能和替代能源委员会, 巴黎萨克雷大学);Department of Physics, Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学物理系);Center for Interdisciplinary Research and Innovation (CIRI-AUTH)(跨学科研究与创新中心);Department for Medical Physics, Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学医学物理系);European Organization for Nuclear Research (CERN)(欧洲核子研究组织);Dipartimento di Fisica, Università di Pavia(帕维亚大学物理系);INFN Sezione di Pavia(意大利国家核物理研究所帕维亚分部);Department of Physics and Astronomy, Stony Brook University(石溪大学物理与天文学系);Institute of Nuclear and Particle Physics, NCSR Demokritos(国家科学研究中心德谟克利特研究所核与粒子物理研究所)
In recent years important progress in micropattern gaseous detectors has been achieved in the use of resistive material to build compact spark-protected devices. The novel idea presented here consists of the polarisation of WELL structures using only resistive coating. This allows a new device to be built with an architecture based on a stack of several coupled layers where drift and WELL multiplication stages alternate in the structure. The signals from each multiplication stage can be read out from any external readout boards through the capacitive couplings. Each layer provides a signal wit…
In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1 cm and 120 cm x 11 cm x 2.5 cm have been studied. An 8-channel SiPM anode readout ASIC (MUSIC R1) based on a novel low input impedance current conveyor has been used to read out and amplify SiPMs independently and sum the signals at the end. Prospects for applications in large-scale particle physics detectors with timing resolution below 100 ps are provided…
The experimental requirements in near future accelerators (e.g. High Luminosity-LHC) has stimulated intense interest in development of detectors with high precision timing capabilities. With this as a goal, a new detection concept called PICOSEC, which is based to a "two-stage" MicroMegas detector coupled to a Cherenkov radiator equipped with a photocathode has been developed. Results obtained with this new detector yield a time resolution of 24\,ps for 150\,GeV muons and 76\,ps for single photoelectrons. In this paper we will report on the performance of the PICOSEC in test beams, as well as …
Low Gain Avalanche Detector (LGAD) is the baseline sensing technology of the recently proposed Minimum Ionizing Particle (MIP) end-cap timing detectors (MTD) at the Atlas and CMS experiments. The current MTD sensor is designed as a multi-pad matrix detector delivering a poor position resolution, due to the relatively large pad area, around 1 $mm^2$; and a good timing resolution, around 20-30 ps. Besides, in his current technological incarnation, the timing resolution of the MTD LGAD sensors is severely degraded once the MIP particle hits the inter-pad region since the signal amplification is m…
I discuss the development of high precision timing detectors for high momentum protons at the LHC, and their application in studying exclusive Higgs boson production.
Central exclusive processes can be studied in CMS by combining the information of the central detector with the Precision Proton Spectrometer (PPS). PPS detectors, placed symmetrically at more than 200 m from the interaction point, can detect the scattered protons that survive the interaction. PPS has taken data at high luminosity while fully integrated in the CMS experiment. The total amount of collected data corresponds to more than 100 fb$^{-1}$ during the LHC Run 2. PPS consists of 3D silicon tracking stations as well as timing detectors that measure both the position and direction of prot…
The use of precise time-of-flight (ToF) detectors for measurements of diffractive and electromagnetic processes in proton-proton collisions is discussed. The performance of background rejection exploiting the ToF measurements of the forward protons is derived. The influence of additional timing measurements delivered by the central detectors is presented and the possible gain is studied.
Recently, the facilities of radioactive ion beam (RIB) combined with advanced detector systems provide us unique opportunity to probe the exotic properties of the nuclei with unusual neutron-to-proton ratio. In this article, a study of characterization of different types of ultra-fast timing detectors: a special type of gas detector (multi-strip multi-gap resistive plate chamber, MMRPC) ($σ$ $<$100 ps), scintillators array ( viz., $LaBr_3:Ce$) (timing resolution ($σ<$250 ps) are being presented. A brief discussion on usage of these different types of ultra-fast timing detector systems at radio…
The LHC timing signals are broadcast to various destinations in the subsequent experiments. And all of them could be delayed to time in the ATLAS sub-detectors by using the Corde board and the RF2TTC module. The ATLAS BPTX detectors and monitoring system could guarantee the demanded sychronization of the beam in the futher collision.
The upgrades of ATLAS and CMS for the High Luminosity LHC (HL-LHC) highlighted physics objects timing as a tool to resolve primary interactions within a bunch crossing. Since the expected pile-up is around 200, with an r.m.s. time spread of 180 ps, a time resolution of about 30 ps is needed. The timing detectors will experience a 1-MeV neutron equivalent fluence of about $Φ_{eq}=10^{14}$ and $10^{15}$ cm$^{-2}$ for the barrel and end-cap regions, respectively. In this contribution, deep diffused Avalanche Photo Diodes (APDs) produced by Radiation Monitoring Devices are examined as candidate ti…
In this talk I discuss the use of calorimeter timing both for detector commissioning and in searches for new physics. In particular I present real and simulated cosmic ray muons data results for the ATLAS Tile Calorimeter system. The analysis shows that several detector errors such as imperfect calibrations can be uncovered. I also demonstrate the use of ATLAS Tile Calorimeters excellent timing resolution in suppressing cosmic ray fake missing transverse energy in searches for supersymmetry.
We investigated the timing jitter of superconducting nanowire avalanche photodetectors (SNAPs, also referred to as cascade switching superconducting single photon detectors) based on 30-nm-wide nanowires. At bias currents (IB) near the switching current, SNAPs showed sub 35 ps FWHM Gaussian jitter similar to standard 100 nm wide superconducting nanowire single-photon detectors. At lower values of IB, the instrument response function (IRF) of the detectors became wider, more asymmetric, and shifted to longer time delays. We could reproduce the experimentally observed IRF time-shift in simulatio…
The DUNE neutrino experiment far detector has a fiducial mass of 40 kt. The O(1 M) readout channels are distributed over the 4 x 10kt modules and need to be synchronized to O( 10 ns ) with a reliable, simple, affordable system. For the majority of channels a simple DC-balanced protocol is used, with clock and synchronization information encoded on the same fibre. The remaining channels use "White Rabbit" (IEEE-1588). Small scale tests show a timing jitter of <100 ps. The DUNE timing system has been successfully prototyped at the ProtoDUNE-SP detector at CERN.
The physics potential of timing layers with a few tens of pico-second resolution in the calorimeters of future collider detectors is explored. These studies show how such layers can be used for particle identification and illustrate the potential for detecting new event signatures originating from physics beyond the standard model.
Precision timing has alway been a prominent topic in the instrumentation for high-energy physics experiments. In this document I discuss what the perspectives are for the use of silicon sensors for a time-of-flight detector in a next-generation heavy-ion experiment at the LHC. A brief overview of the experiment and a preliminary assessment of the expected particle-identification performance is also presented.
Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with $10 \times 10\ \mathrm{cm}^{2}$ active area
European Organization for Nuclear Research (CERN)(欧洲核子研究中心);Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Center for Interdisciplinary Research and Innovation (CIRI-AUTH)(跨学科研究与创新中心);Institut de Recherche sur les lois Fondamentales de l’Univers (IRFU, CEA)(基础定律宇宙研究所);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学)
The PICOSEC Micromegas detector can time the arrival of Minimum Ionizing Particles with a sub-25 ps precision. A very good timing resolution in detecting single photons is also demonstrated in laser beams. The PICOSEC timing resolution is determined mainly by the drift field. The arrival time of the signal and the timing resolution vary with the size of the pulse amplitude. Detailed simulations based on GARFIELD++ reproduce the experimental PICOSEC timing characteristics. This agreement is exploited to identify the microscopic physical variables, which determine the observed timing properties.…
We report experimental test-beam results on dielectric-loaded waveguide detectors that utilize microwave Cherenkov signals to time and characterize high energy particle showers. These results are used to validate models and produce high-fidelity simulations of timing plane systems which yield picosecond time tags and millimeter spatial coordinates for the shower centroid. These timing planes, based on the Askaryan effect in solid dielectrics, are most effective at the high center-of-momentum energies planned for the Future Circular Collider (FCC-hh), and are of particular interest in the forwa…
Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
CERN(欧洲核子研究组织);Aristotle University of Thessaloniki(塞萨洛尼基亚里士多德大学);Ludwig Maximilian University of Munich(慕尼黑路德维希-马克西米利安大学);Stony Brook University(石溪大学);NCSR Demokritos(德谟克利特国家科学研究中心);Laboratório de Instrumentação e Física Experimental de Partículas (LIP)(粒子物理与实验仪器实验室);University of Helsinki(赫尔辛基大学);Jefferson Lab(杰斐逊国家加速器装置);University of Zagreb(萨格勒布大学);University of Science and Technology of China(中国科学技术大学);University of Bonn(波恩大学);CEA-Saclay(法国原子能和替代能源委员会萨克雷中心);National Technical University of Athens(雅典国立技术大学);Ruđer Bošković Institute(鲁杰尔·博什科维奇研究所);University of Virginia(弗吉尼亚大学)
Differentiable Full Detector Simulation of a Projective Dual-Readout Crystal Electromagnetic Calorimeter with Longitudinal Segmentation and Precision Timing
This paper presents results that take a critical step toward proving 10 ps timing resolution's feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of 35 micro-m and 50 micro-m are evaluated with a 120 GeV proton beam. The performance of the gain and timing response is assessed, including the dependence on the reverse bias voltage and operating temperature. The best timing resolution of UFSDs in a test beam to date is achieved using three combined planes of 35 micro-m thick LGADs at -30 degree celsius with…
We describe the new fast timing readout chip SAMPIC developed in CEA Saclay and in LAL Orsay (France) as well as the results of differents tests performed using that chip.
The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in developing technologies for charged particle detection with accurate timing at high rates. The required accuracy follows directly from the nominal interaction distribution within a bunch crossing ($σ_z\sim5$ cm, $σ_t\sim170$ ps). A time resolution of the order of 20-30 ps would lead to significant reduction of these backgrounds. With this goal, we present a new detection concept called PICOSEC, which is based on a "two-stage" Micromegas detector coupled to a Cherenkov radiator and …
Development of a high-granularity, high-precision timing readout electronics system for large-area MRPC detectors
Institute of Nuclear and Particle Physics, School of Physics and Astronomy, Shanghai Jiao Tong University(上海交通大学物理与天文学院核粒子物理研究所);Key Laboratory for Particle Astrophysics and Cosmology (MoE), Shanghai Key Laboratory for Particle Physics and Cosmology(教育部粒子天体物理与宇宙学重点实验室,上海粒子物理与宇宙学重点实验室);Institut de Physique des 2 Infinis de Lyon, Lyon University(里昂大学里昂双无限物理研究所);Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所)
本研究针对含2400个2*2 cm pad通道的大面积MRPC探测器,研发了由FEBs、时钟模块、DAQ聚合器及PETIROC2B ASIC组成的高粒度高精度定时读出系统,其单通道时间分辨率达33 ps RMS,可应用于多种定时探测器场景。
We describe a start-timing detector for the PHENIX experiment at the relativistic heavy-ion collider RHIC. The role of the detector is to detect a nuclear collision, provide precise time information with an accuracy of 50ps, and determine the collision point along the beam direction with a resolution of a few cm. Technical challenges are that the detector must be operational in a wide particle-multiplicity range in a high radiation environment and a strong magnetic field. We present the performance of the prototype and discuss the final design of the detector.
Silicon tracking detectors provide excellent spatial resolution, and so can provide excellent momentum resolution for energetic charged particles, even in compact detectors. However, at lower momenta, multiple scattering in the silicon degrades the momentum resolution. We present an alternate method to measure momentum and alleviate this degradation, using silicon detectors that also incorporate timing measurements. By using timing information between two silicon layers, it is possible to solve for the the radius of curvature, and hence the particle momentum, independent of multiple scattering…
The Compact Muon Solenoid (CMS) detector at the CERN Large Hadron Collider (LHC) is undergoing an extensive Phase II upgrade program to prepare for the challenging conditions of the High-Luminosity LHC (HL-LHC). A new timing layer is designed to measure minimum ionizing particles (MIPs) with a time resolution of 30 ps and a hermetic coverage up to a pseudo-rapidity of $|η|$ = 3. This MIP Timing Detector(MTD) will consist of a central barrel region based on LYSO:Ce crystals read out with SiPMs and two end-caps instrumented with radiation-tolerant Low Gain Avalanche Diodes (LGADs). The precision…
Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particles multiplicities on the detection systems. The PICOSEC Micromegas detector has demonstrated the ability to time 150\,GeV muons with a sub-25\,ps precision. Driven by detailed simulation studies and a phenomenological model which describes stochastically the dynamics of the signal formation, new PICOSEC designs were developed that significantly improve the timing performance of the detector. PICOSEC prototypes with reduced drift gap size ($…
Future experiments of nuclear and particle physics are moving towards the high luminosity regime, in order to access suppressed processes like rare B decays or exotic charmonium resonances. In this scenario, high rate capability is a key requirement for electronics instrumentation, together with excellent timing resolution for precise event reconstruction. The development of dedicated FrontEnd Electronics (FEE) for detectors has become increasingly challenging. A current trend in R&D is towards multipurpose FEE which can be easily adapted to a great variety of detectors, without impairing the …
The recently approved India-based Neutrino Observatory will use the world's largest magnet to study atmospheric muon neutrinos. The 50 kiloton Iron Calorimeter consists of iron alternating with single-gap resistive plate chambers. A uniform magnetic field of $\sim$1.5 T is produced in the iron using toroidal-shaped copper coils. Muon neutrinos interact with the iron target to produce charged muons, which are detected by the resistive plate chambers, and tracked using orthogonal pick up strips. Timing information for each layer is used to discriminate between upward and downward traveling muons…
In recent years, SiPM photoelectric devices have drawn much attention in the domain of time-of-flight-based positron emission tomography (TOF-PET). Using them to construct PET detectors with excellent coincidence time resolution (CTR) is always one of research focus. In this paper, a SiPM readout pre-amplifier based on common-base current amplifier structure followed by a Pole-Zero (PZ) compensation network is constructed, and the main factors that affect the timing performance of the PET detector are investigated. By experimental measurement, we found that the CTR is heavily related to the ba…
A simulation model is developed to train Artificial Neural Networks (ANN), for precise timing of PICOSEC Micromegas detector signals. The aim is to develop fast, online timing algorithms as well as minimising the information to be saved during data acquisition. PICOSEC waveforms were collected and digitised by a fast oscilloscope during a femptosecond-laser test beam run. A data set comprising waveforms collected with attenuated laser beam intensity, eradicating the emission of more than one photoelectron per light pulse from the PICOSEC photocathode, was utilised by a simulation algorithm to …
The SAMpler for PICosecond time (SAMPIC) chip has been designed by a collaboration including CEA/IRFU/SEDI, Saclay and CNRS/LAL/SERDI, Orsay. It benefits from both the quick response of a time to digital converter and the versatility of a waveform digitizer to perform accurate timing measurements. Thanks to the sampled signals, smart algorithms making best use of the pulse shape can be used to improve time resolution. A software framework has been developed to analyse the SAMPIC output data and extract timing information by using either a constant fraction discriminator or a fast cross-correla…
Test beam measurements have been carried out with a 3D sensor on a Timepix3 ASIC and the time measurements are presented. The measurements are compared to those of a thin planar sensor on Timepix3. It is shown that for a perpendicularly incident beam the time resolution of both detectors is dominated by the Timepix3 front-end. The 3D detector is dominated by the time-to-digital conversion whereas the analog front-end jitter also gives a significant contribution for the thin planar detector. The 3D detector reaches an overall time resolution of 567(6)ps compared to 683(8)ps for the thin planar …
High-Resolution Timing for Vertex-Reconstructed Muon-Spin Spectroscopy Using Plastic Scintillators and MuTRiG
Kirchhoff Institute for Physics, Heidelberg University(海德堡大学基尔霍夫物理研究所);Institute for Nuclear Physics, Johannes Gutenberg-Universität Mainz(约翰内斯·古腾堡美因茨大学核物理研究所);PSI Center for Neutron and Muon Sciences(瑞士保罗谢勒研究所中子与μ子科学中心);Institute for Particle Physics and Astrophysics, ETH Zürich(苏黎世联邦理工学院粒子物理与天体物理研究所);Physics Institute, Heidelberg University(海德堡大学物理研究所)
We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at $-30^{\circ}$.