arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1608.06122cond-mat.mes-hall
收藏

用于低温测量的优化金属共面谐振器

Metallic coplanar resonators optimized for low-temperature measurements

Mojtaba Javaheri Rahim, Thomas Lehleiter, Daniel Bothner, Cornelius Krellner, Dieter Koelle, Reinhold Kleiner, Martin Dressel, Marc Scheffler

摘要:

金属共面微波谐振器在室温下得到了广泛的应用,但其低温性能却很少受到关注。我们的特点是紧凑的铜共面谐振器与多个模式从2.5到20 GHz的温度低至5 K。我们研究了中心导体宽度(20至100 μm)和耦合间隙尺寸(10至50 μm)的影响,我们观察到较宽的中心导体的品质因数(Q)大幅增加,最高可达470。谐振器的磁场依赖性很弱,对于7 T的外加场,Q的最大变化为3.5%。这使得这些金属谐振器非常适合磁共振研究,因为我们在多个共振频率下用电子自旋共振(ESR)测量记录。

英文摘要:

Metallic coplanar microwave resonators are widely employed at room temperature, but their low-temperature performance has received little attention so far. We characterize compact copper coplanar resonators with multiple modes from 2.5 to 20 GHz at temperatures as low as 5 K. We investigate the influence of center conductor width (20 to 100 μm) and coupling gap size (10 to 50 μm), and we observe a strong increase of quality factor (Q) for wider center conductors, reaching values up to 470. The magnetic-field dependence of the resonators is weak, with a maximum change in Q of 3.5% for an applied field of 7 T. This makes these metallic resonators well suitable for magnetic resonance studies, as we document with electron spin resonance (ESR) measurements at multiple resonance frequencies.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑