arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1303.3504physics.med-ph
收藏

截断剂量沉积系数矩阵优化IMRT的定点迭代法

The fixed-point iteration method for IMRT optimization with truncated dose deposition coefficient matrix

Zhen Tian, Masoud Zarepisheh, Xun Jia, Steve B. Jiang

摘要:

在调强放射治疗(IMRT)的治疗计划优化中,剂量沉积系数(DDC)矩阵通常被预先计算,以参数化单位强度的每个子束对感兴趣体积中每个体素的剂量贡献。然而,由于计算机内存的限制和对计算效率的要求,在实践中,小值的矩阵元素通常被截断,这不可避免地损害了所得计划的质量。一个固定点迭代计划已被应用在调强放射治疗优化来解决这个问题,已被报道是有效的和高效的数值实验的观察的基础上。在本文中,我们的目的是指出这一计划背后的数学和回答以下三个问题:1)是否不动点迭代算法收敛或不?2)当收敛时,不动点解是否与用完全DDC矩阵得到的原解相同?3)如果不相同,不动点解是否比不经不动点迭代得到的截断问题的朴素解更精确?为了回答这些问题,我们首先使用简化的注量图优化(FMO)模型进行数学分析和推导。然后,我们进行了数值实验的头颈部病人的情况下,使用简化和原始的FMO模型。我们的数学分析和数值实验表明,适当的DDC矩阵截断,不动点迭代收敛。即使收敛的解决方案是不是一个,我们得到的完整的DDC矩阵,固定点迭代方案可以显着提高计划的精度相比,截断问题的解决方案,没有固定点迭代。

英文摘要:

In the treatment plan optimization for intensity modulated radiation therapy (IMRT), dose-deposition coefficient (DDC) matrix is often pre-computed to parameterize the dose contribution to each voxel in the volume of interest from each beamlet of unit intensity. However, due to the limitation of computer memory and the requirement on computational efficiency, in practice matrix elements of small values are usually truncated, which inevitably compromises the quality of the resulting plan. A fixed-point iteration scheme has been applied in IMRT optimization to solve this problem, which has been reported to be effective and efficient based on the observations of the numerical experiments. In this paper, we aim to point out the mathematics behind this scheme and to answer the following three questions: 1) whether the fixed-point iteration algorithm converges or not? 2) when it converges, whether the fixed point solution is same as the original solution obtained with the complete DDC matrix? 3) if not the same, whether the fixed point solution is more accurate than the naive solution of the truncated problem obtained without the fixed-point iteration? To answer these questions, we first performed mathematical analysis and deductions using a simplified fluence map optimization (FMO) model. Then we conducted numerical experiments on a head-and-neck patient case using both the simplified and the original FMO model. Both our mathematical analysis and numerical experiments demonstrate that with proper DDC matrix truncation, the fixed-point iteration can converge. Even though the converged solution is not the one that we obtain with the complete DDC matrix, the fixed-point iteration scheme could significantly improve the plan accuracy compared with the solution to the truncated problem obtained without the fixed-point iteration.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑