俄歇电子发射放射性核素的吸收剂量评价:输入衰变谱对剂量点核和S值的影响
Absorbed dose evaluation of Auger electron-emitting radionuclides: impact of input decay spectra on dose point kernels and S-values
摘要:
本研究的目的是研究新开发的随机原子弛豫模型BrIccEmis提供的衰变数据对剂量点核的影响(DPKs -单位点源周围的径向剂量分布)和S值14种俄歇电子放射性核素,即67 Ga、80 mBr、89 Zr、90 Nb、99 mTc、111 In、117 mSn,119 Sb、123 I、124 I、125 I、135 La、195 mPt和201 Tl。辐射光谱基于医学内辐射剂量(MIRD)RADTABS程序和BrIccEmis代码的核衰变数据,假设采用孤立原子和凝聚相方法。DPK的模拟与PENMENTPE蒙特卡罗(MC)代码使用事件的电子和光子传输。使用适当的几何缩减因子,从这些DPKS中推导出各种大小的同心球形细胞的S值。MIRD-RADTABS的俄歇和Coster-Kronig(CK)电子数和每次核衰变释放的X射线光子数(产率)始终高于使用BrIccEmis计算的值。BrIccEmis电子光谱的DPKs与MIRD-RADTABS有很大的不同,在距离点源的前几百纳米处,大多数俄歇电子都被阻止了。然而,S值没有受到显著影响,因为亚微米尺寸的DPKS差异在较大尺寸中迅速减小。MIRD-RADTABS的总AE能量输出的高估导致较高的预测能量沉积的AE发射放射性核素,特别是在附近的衰变的放射性核素。当MIRD-RADTABS数据用于模拟纳米尺度的生物损伤时,应考虑到这一点。
英文摘要:
The aim of this study was to investigate the impact of decay data provided by the newly developed stochastic atomic relaxation model BrIccEmis on dose point kernels (DPKs - radial dose distribution around a unit point source) and S-values (absorbed dose per unit cumulated activity) of 14 Auger electron (AE) emitting radionuclides, namely 67Ga, 80mBr, 89Zr, 90Nb, 99mTc, 111In, 117mSn, 119Sb, 123I, 124I, 125I, 135La, 195mPt and 201Tl. Radiation spectra were based on the nuclear decay data from the medical internal radiation dose (MIRD) RADTABS program and the BrIccEmis code, assuming both an isolated-atom and condensed-phase approach. DPKs were simulated with the PENELOPE Monte Carlo (MC) code using event-by-event electron and photon transport. S-values for concentric spherical cells of various sizes were derived from these DPKS using appropriate geometric reduction factors. The number of Auger and Coster-Kronig (CK) electrons and x-ray photons released per nuclear decay (yield) from MIRD-RADTABS were consistently higher than those calculated using BrIccEmis. DPKs for the electron spectra from BrIccEmis were considerably different from MIRD-RADTABS in the first few hundred nanometres from a point source where most of the Auger electrons are stopped. S-values were, however, not significantly impacted as the differences in DPKS in the sub-micrometre dimension were quickly diminished in larger dimensions. Overestimation in the total AE energy output by MIRD-RADTABS leads to higher predicted energy deposition by AE emitting radionuclides, especially in the immediate vicinity of the decaying radionuclides. This should be taken into account when MIRD-RADTABS data are used to simulate biological damage at nanoscale dimensions.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。