arXiv 1002.0560nucl-ex
收藏

具有CaWO4闪烁体和低至6 K的低温光电倍增管的低温闪烁模块的首次试验

First test of a cryogenic scintillation module with a CaWO4 scintillator and a low-temperature photomultiplier down to 6 K

H. Kraus, V. B. Mikhailik

摘要:

未来寻找罕见事件的低温实验需要可靠,高效和强大的技术,用于在远低于低温光电倍增管(PMT)的温度下检测光子。受此启发,我们研究的可行性,低温光电倍增管的闪烁检测晶体闪烁器在T = 6 K。闪烁模块由CaWO 4闪烁体和来自ET Enterprises的低温PMT D 745 B组成。PMT的响应度进行了研究,在T=290,77和6 K使用的γ-量子从241 Am(60 keV)和57 Co(122和136 keV)源。我们已经表明,低温PMT保持其单光子计数能力,即使在低温。在T = 6 K时,当在光子计数和脉冲高度模式下评估时,PMT的响应分别降低到51 ± 13%和27 ± 6%。由于CaWO 4闪烁晶体的光产额增加,当冷却至T = 6 K时,闪烁模块CaWO 4 +PMT的总响应度为94 ± 15%(光子计数)和48 ± 8%(脉冲高度)。暗计数率为20 s-1。该模块的能量分辨率保持类似于在室温下使用任一检测模式测量的能量分辨率。它的结论是,市售的低温光电倍增管是非常适合在低温下的闪烁光的检测。

英文摘要:

Future cryogenic experiments searching for rare events require reliable, efficient and robust techniques for the detection of photons at temperatures well below that to which low-temperature photomultipliers (PMT) were characterised. Motivated by this we investigated the feasibility of a low-temperature PMT for the detection of scintillation from crystalline scintillators at T = 6 K. The scintillation module was composed of a CaWO4 scintillator and a low-temperature PMT D745B from ET Enterprises. The PMT responsivity was studied at T=290, 77 and 6 K using gamma-quanta from 241Am (60 keV) and 57Co (122 and 136 keV) sources. We have shown that the low-temperature PMT retains its single photon counting ability even at cryogenic temperatures. At T = 6 K, the response of the PMT decreases to 51 +- 13 % and 27 +- 6 % when assessed in photon counting and pulse height mode, respectively. Due to the light yield increase of the CaWO4 scintillating crystal the overall responsivity of the scintillation modules CaWO4+PMT is 94 +- 15 % (photon counting) and 48 +- 8 % (pulse height) when cooling to T = 6 K. The dark count rate was found to be 20 s-1. The energy resolution of the module remains similar to that measured at room temperature using either detection mode. It is concluded that commercially available low-temperature PMT are well suited for detection of scintillation light at cryogenic temperatures.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑