arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1001.0780astro-ph.COastro-ph.GA
收藏

LoCuSS:XMM-牛顿和斯巴鲁星系团质量测量的比较--流体静力平衡和非热压力支持的偏差检验

LoCuSS: A Comparison of Cluster Mass Measurements from XMM-Newton and Subaru - Testing Deviation from Hydrostatic Equilibrium and Non-Thermal Pressure Support

Yu-Ying Zhang, Nobuhiro Okabe, Alexis Finoguenov, Graham P. Smith, Rocco Piffaretti, Riccardo Valdarnini, Arif Babul, August E. Evrard, Pasquale Mazzotta, Alast… 展开作者

Yu-Ying Zhang, Nobuhiro Okabe, Alexis Finoguenov, Graham P. Smith, Rocco Piffaretti, Riccardo Valdarnini, Arif Babul, August E. Evrard, Pasquale Mazzotta, Alastair J. R. Sanderson, Daniel P. Marrone

摘要:

We compare X-ray hydrostatic and weak-lensing mass estimates for a sample of 12 clusters that have been observed with both XMM-Newton and Subaru. At an over-density of Δ=500, we obtain 1-M^{X}/M^{WL}=0.01+/-0.07 for the whole sample. We also divided the sample into undisturbed and disturbed sub-samples based on quantitative X-ray morphologies using asymmetry and fluctuation parameters, obtaining 1-M^{X}/M^{WL}=0.09+/-0.06 and -0.06+/-0.12 for the undisturbed and disturbed clusters, respectively. In addition to non-thermal pressure support, there may be a competing effect associated with adiabatic compression and/or shock heating which leads to overestimate of X-ray hydrostatic masses for disturbed clusters, for example, in the famous merging cluster A1914. Despite the modest statistical significance of the mass discrepancy, on average, in the undisturbed clusters, we detect a clear trend of improving agreement between M^{X} and M^{WL} as a function of increasing over-density, M^{X}/M^{WL}=(0.908+/-0.004)+(0.187+/-0.010) \log_{10} (Δ/500). We also examine the gas mass fractions, f_{gas} =M^{gas}/M^{WL}, finding that they are an increasing function of cluster radius, with no dependence on dynamical state, in agreement with predictions from numerical simulations. Overall, our results demonstrate that XMM-Newton and Subaru are a powerful combination for calibrating systematic uncertainties in cluster mass measurements.

英文摘要:

We compare X-ray hydrostatic and weak-lensing mass estimates for a sample of 12 clusters that have been observed with both XMM-Newton and Subaru. At an over-density of Δ=500, we obtain 1-M^{X}/M^{WL}=0.01+/-0.07 for the whole sample. We also divided the sample into undisturbed and disturbed sub-samples based on quantitative X-ray morphologies using asymmetry and fluctuation parameters, obtaining 1-M^{X}/M^{WL}=0.09+/-0.06 and -0.06+/-0.12 for the undisturbed and disturbed clusters, respectively. In addition to non-thermal pressure support, there may be a competing effect associated with adiabatic compression and/or shock heating which leads to overestimate of X-ray hydrostatic masses for disturbed clusters, for example, in the famous merging cluster A1914. Despite the modest statistical significance of the mass discrepancy, on average, in the undisturbed clusters, we detect a clear trend of improving agreement between M^{X} and M^{WL} as a function of increasing over-density, M^{X}/M^{WL}=(0.908+/-0.004)+(0.187+/-0.010) \log_{10}(Δ/500). We also examine the gas mass fractions, f_{gas}=M^{gas}/M^{WL}, finding that they are an increasing function of cluster radius, with no dependence on dynamical state, in agreement with predictions from numerical simulations. Overall, our results demonstrate that XMM-Newton and Subaru are a powerful combination for calibrating systematic uncertainties in cluster mass measurements.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑