MINOS近、远探测器读出系统在测试束上的比较

Comparisons of the MINOS Near and Far Detector Readout Systems at a Test Beam

A. Cabrera, P. Adamson, M. Barker, A. Belias, S. Boyd, G. Crone, G. Drake, E. Falk, P. G. Harris, J. Hartnell, L. Jenner, M. Kordosky, K. Lang, R. P. Litchfield… 展开作者

A. Cabrera, P. Adamson, M. Barker, A. Belias, S. Boyd, G. Crone, G. Drake, E. Falk, P. G. Harris, J. Hartnell, L. Jenner, M. Kordosky, K. Lang, R. P. Litchfield, D. Michael, P. S. Miyagawa, R. Morse, S. Murgia, R. Nichol, T. Nicholls, G. F. Pearce, D. Petyt, D. Reyna, R. Saakyan, P. Shanahan, C. Smith, P. Symes, N. Tagg, J. Thomas, P. Vahle, A. Weber

摘要:

MINOS是一个长基线中微子振荡实验,使用两个相距734公里的探测器。用于两个探测器的读出系统是不同的,必须独立校准。为了验证并直接比较两个读出系统的校准响应,使用较小的校准检测器获取测试光束数据。该探测器同时装有两个读出系统,并暴露于CERN PS T7测试束。两个系统的校准响应的差异所示的响应非线性,光电倍增管串扰,和阈值效应的差异在百分之几的水平。这些差异再现的Monte Carlo(MC)模拟优于1%,并提出了一种方案,通过校准MC匹配的数据,分别在每个检测器,以纠正这些差异。两个读出系统之间的量热响应的整体差异被证明是一致的,零到1.3%的精度的数据和0.3%的MC没有显着的能量依赖性。

英文摘要:

MINOS is a long baseline neutrino oscillation experiment that uses two detectors separated by 734 km. The readout systems used for the two detectors are different and have to be independently calibrated. To verify and make a direct comparison of the calibrated response of the two readout systems, test beam data were acquired using a smaller calibration detector. This detector was simultaneously instrumented with both readout systems and exposed to the CERN PS T7 test beam. Differences in the calibrated response of the two systems are shown to arise from differences in response non-linearity, photomultiplier crosstalk, and threshold effects at the few percent level. These differences are reproduced by the Monte Carlo (MC) simulation to better than 1% and a scheme that corrects for these differences by calibrating the MC to match the data in each detector separately is presented. The overall difference in calorimetric response between the two readout systems is shown to be consistent with zero to a precision of 1.3% in data and 0.3% in MC with no significant energy dependence.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑