The use of one or more gold nanoballs as reference objects for Fourier Transform holography (FTH) is analysed using experimental soft X-ray diffraction from objects consisting of separated clusters of these balls. The holograms are deconvoluted against ball reference objects to invert to images, in combination with a Wiener filter to control noise. A resolution of ~30nm, smaller than one ball, is obtained even if a large cluster of balls is used as the reference, giving the best resolution yet obtained by X-ray FTH. Methods of dealing with missing data due to a beamstop are discussed. Practical prepared objects which satisfy the FTH condition are suggested, and methods of forming them described.
Strict requirements were imposed on the sizes of testing sample in the previously suggested scheme of hard X-ray Fourier-transform holography based on a two-block Fresnel zone plate interferometer with common optical axis. The failure of these requirements leads to appearance of noise in the reconstructed image. In this work, the mechanism of noise formation, as well as possibility of its suppression are considered.
We report a demonstration of laser Doppler holography at a sustained acquisition rate of 250 Hz on a 1 Megapixel complementary metal-oxide-semiconductor (CMOS) sensor array and image display at 10 Hz frame rate. The holograms are optically acquired in off-axis configuration, with a frequency-shifted reference beam. Wide-field imaging of optical fluctuations in a 250 Hz frequency band is achieved by turning time-domain samplings to the dual domain via short-time temporal Fourier transformation. The measurement band can be positioned freely within the low radio-frequency spectrum by tuning the f…
The Differential Fourier Holography (DFH) gives an exact mathematical solution of the inverse problem of diffraction in the Fraunhofer regime. After the first publication [1] the Differential Fourier Holography was successfully applied in many experiments to obtain amplitude and phase information about two-dimensional (2D) images. In this article we demonstrate numerically the possibility to apply the DFH also for investigation of unknown 3D Objects. The first simulation is made for a double-spiral structure plus a line as a reference object.
We demonstrate single and multi-shot Fourier transform holography with the use of a tabletop extreme ultraviolet laser. The reference wave was produced by a Fresnel zone plate with a central opening that allowed the incident beam to illuminate the sample directly. The high reference wave intensity allows for larger objects to be imaged compared to mask-based lensless Fourier transform holography techniques. We obtain a spatial resolution of 169 nm from a single laser pulse and a resolution of 128 nm from an accumulation of 20 laser pulses for an object ~11x11μm 2 in size. This experiment utili…
Ultrafast X-ray imaging provides high resolution information on individual fragile specimens such as aerosols, metastable particles, superfluid quantum systems and live biospecimen, which is inaccessible with conventional imaging techniques. Coherent X-ray diffractive imaging, however, suffers from intrinsic loss of phase, and therefore structure recovery is often complicated and not always uniquely-defined. Here, we introduce the method of in-flight holography, where we use nanoclusters as reference X-ray scatterers in order to encode relative phase information into diffraction patterns of a …
Digital in-line holography in thick optical systems: application to visualization in pipes
在本文中,我们应用数字同轴全息术,通过一个厚的平凹管道成像不透明的物体。考虑不透明纤维和不透明颗粒。利用广义菲涅耳变换,推导出CCD传感器面内光强分布的解析表达式。\textbf{The proposed model has the ability to deal with various pipe shape and thickness and compensates for the lack of versatility of classical DIH models. Holograms obtained with a 12 mm thick plano-concave pipe are then reconstructed using fractional Fourier transform (FRFT).}这种方法可以让我们摆脱散光。数值和实验结果。
We performed non-invasive video imaging of retinal blood flow in a pigmented rat by holographic interferometry of near-infrared laser light backscattered by retinal tissue, beating against an off-axis reference beam sampled at a frame rate of 39 kHz with a high throughput camera. Local Doppler contrasts emerged from the envelopes of short-time Fourier transforms and the phase of autocorrelation functions of holograms rendered by Fresnel transformation. This approach permitted imaging of blood flow in large retinal vessels (30 microns diameter) over 400 by 400 pixels with a spatial resolution o…
In recent years nanoscale coherent imaging has emerged as an indispensable imaging modality allowing to surpass the resolution limit given by classical imaging optics. At the same time, attosecond science has experienced enormous progress and has revealed the ultrafast dynamics in atoms, molecules, and complex materials. Combining attosecond temporal resolution of pump-probe experiments with nanometer spatial resolution would allow studying ultrafast dynamics on the smallest spatio-temporal scales but has not been demonstrated yet. Unfortunately, the large bandwidth of attosecond pulses usuall…
In numerous applications, Fourier-domain optical coherence tomography (FD-OCT) suffers from a limited imaging depth due to signal roll-off, a limited focal range, and autocorrelation noise. Here, we propose a parallel full-field FD-OCT imaging method that uses a swept laser source and an area camera in combination with an off-axis reference, which is incident on the camera at a small angle. As in digital off-axis holography, this angle separates autocorrelation signals and the complex conjugated mirror image from the actual signal in Fourier space. We demonstrate that by reconstructing the sig…