arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2607.04524cs.NI
收藏

无线气体泄漏检测与定位

Wireless Gas Leak Detection and Localization

Berkeley Sensor and Actuator Center, University of California, Berkeley(加州大学伯克利分校传感器与执行器中心)

Fabien Chraim, Yusuf Bugra Erol, Kris Pister

AI总结:

针对工业气体泄漏问题,提出无线检测与定位解决方案,通过监测网络收集数据,应用算法评估,取得91%检测率、三天七次误报、平均108秒检测延迟及5米定位精度等成果,并给出气体传感器设计建议。

摘要:

每年发生数千起工业气体泄漏事件,造成诸多危害。虽有诸多尝试但成效有限。本文提出无线气体泄漏检测与定位解决方案。利用覆盖200平方米的20个无线设备监测网络进行60次丙烷释放实验,将算法应用于收集的浓度数据并评估方法。实现了91%的检测率,三天记录到七次误报,平均检测延迟108秒,定位精度为5米。随后给出了未来爆炸性气体传感器设计的建议。

英文摘要:

Thousands of industrial gas leaks occur every year, with many leading to injuries, deaths, equipment damage, and a disastrous environmental effect. There have been many attempts at solving this problem, but with limited success. This paper proposes a wireless gas leak detection and localization solution. With a monitoring network of 20 wireless devices covering 200m^2, 60 propane releases are performed. The detection and localization algorithms proposed here are applied to the collected concentration data, and the methodology is evaluated. A detection rate of 91% is achieved, with seven false alarms recorded over three days, and an average detection delay of 108 seconds. The localization results show an accuracy of 5 meters. Recommendations for future explosive gas sensor design are then presented.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑