用于研究Aditya-U托卡马克中约束逃逸电子的薄靶硬X射线轫致辐射探测系统开发

Development of a thin-target hard X-ray bremsstrahlung detection system to study confined runaway electrons in Aditya-U Tokamak

Institute for Plasma Research(等离子体研究所);Homi Bhabha National Institute (HBNI)(霍米·巴巴国立学院);EPFL(洛桑联邦理工学院);Indian Space Research Organisation(印度空间研究组织);Saha Institute for Nuclear Physics(萨哈核物理研究所)
Suman Dolui, Santosh Pandya, J. Kumar, Bharat Hegde, Kaushlender Singh, J. Ghosh, Komal Yadav, Mitul Abhangi, Shishir Purohit, Minsha Shah, Laxmikanta Pradhan, … 展开作者

Suman Dolui, Santosh Pandya, J. Kumar, Bharat Hegde, Kaushlender Singh, J. Ghosh, Komal Yadav, Mitul Abhangi, Shishir Purohit, Minsha Shah, Laxmikanta Pradhan, Harshita Raj, R. L. Tanna, Ashok K. Kumawat, Injamul Hoque, Soumitra Banerjee, Ruchi Varshney, S. Aich, Rohit Kumar, K. A. Jadeja, K. M. Patel, M. K. Gupta, P. K. Chattopadhyay, A. Sen, Y. C. Saxena, R. Pal

AI总结:

开发了带铅准直器的CdTe探测器硬X射线监测系统,测量芯部等离子体区域的薄靶轫致辐射,通过正向建模验证,用于研究锯齿活动期间快电子动力学。

摘要:

开发并安装在Aditya-U托卡马克上的一个特殊屏蔽的CdTe探测器基硬X射线(HXR)监测系统,配备铅准直器,用于研究锯齿活动期间产生的快电子(~20-200 keV)动力学。Aditya-U中已有的HXR监测器暴露于来自等离子体体积、外围限制器和其他结构部件的整个HXR轫致辐射,这限制了其单独研究损失和约束逃逸电子(REs)动力学的能力。相比之下,新开发的诊断成功测量了涵盖芯部等离子体区域(特别是在锯齿反转半径内及其周围)的弦平均薄靶HXR轫致辐射发射。通过结合等离子体参数、约束RE特性和诊断系统几何配置的正向建模代码验证了测量的HXR谱。结果证实了所开发的HXR监测器探测内部等离子体不稳定性期间快电子动力学的能力。

英文摘要:

A specially shielded CdTe detector based hard X-ray (HXR) monitoring system equipped with a lead collimator has been developed and installed on the Aditya-U tokamak to investigate the dynamics of fast electrons (~20-200 keV) generated during sawtooth activity. The pre-existing HXR monitor in Aditya-U is exposed to the entire HXR bremsstrahlung emission from the plasma volume, peripheral limiters, and other structural components, which limits its ability to separately study the dynamics of lost and confined runaway electrons (REs). In contrast, the newly developed diagnostic has successfully measured the chord-averaged thin-target HXR bremsstrahlung emission encompassing the core plasma region, particularly within and around the sawtooth inversion radius. The measured HXR spectra are validated through forward modelling code that incorporates plasma parameters, confined RE characteristics, and the geometric configuration of the diagnostic system. The results confirm the capability of the developed HXR monitor to probe the fast-electron dynamics during internal plasma instabilities.