arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2606.14766cs.CVcs.AIcs.MA
收藏

XMedFusion:面向自主医疗系统的知识引导多模态感知与推理框架

XMedFusion: A Knowledge-Guided Multimodal Perception and Reasoning Framework for Autonomous Medical Systems

National University of Sciences and Technology (NUST)(巴基斯坦国立科技大学);University of Oxford(牛津大学)

Hamza Riaz, Arham Haroon, Maha Baig, Muhammad Dawood Rizwan, Muhammad Naseer Bajwa, Muhammad Moazam Fraz

AI总结:

提出XMedFusion模块化AI框架,通过视觉感知、知识图谱构建和检索引导生成等智能体协同,增强放射学报告生成的视觉基础与临床发现捕捉能力,在公共数据集上显著优于基线模型。

摘要:

自主医疗和机器人系统日益依赖智能感知与推理能力来解释视觉数据并支持临床决策。放射学报告生成是此类自动化诊断工作流的关键组成部分,然而现有的端到端多模态模型常因视觉基础薄弱而导致不可靠的解释和细微临床发现的遗漏。本文提出XMedFusion,一个模块化AI框架,设计为自主医疗系统的智能感知与推理模块。该框架将视觉信息分解为协调的功能组件,模拟专家驱动的分析,包括提取图像基础证据的视觉感知智能体、构建临床相关发现结构的知识图谱构建智能体,以及确保报告结构一致的检索引导起草过程。合成智能体通过推理驱动的验证迭代整合视觉和结构化证据,生成可靠且可解释的诊断输出。在公共胸部X光片数据集上的实验评估表明,与基线视觉-语言模型相比,在BLEU-1上提升0.0493至0.3359,ROUGE-L上提升0.0863至0.2440,METEOR上提升0.0829至0.1708,同时在语义评估指标如一致性(2.38至7.80)和准确性(2.34至6.93)上也有显著提升。结果突出了结构化多智能体感知与推理在增强智能医学成像系统的鲁棒性、透明度和自动化方面的有效性,使其能够集成到自主医疗和机器人诊断工作流中。

英文摘要:

Autonomous medical and robotic systems increasingly rely on intelligent perception and reasoning capabilities to interpret visual data and support clinical decision making. Radiology report generation represents a critical component of such automated diagnostic workflows, yet existing end-to-end multimodal models often suffer from weak visual grounding, resulting in unreliable interpretations and omission of subtle clinical findings. This paper presents XMedFusion, a modular AI framework designed as an intelligent perception and reasoning module for autonomous medical systems. The proposed framework decomposes visual information into coordinated functional components that emulate expert-driven analysis, including a visual perception agent that extracts image-grounded evidence, a knowledge graph construction agent that structures clinically relevant findings, and a retrieval-guided drafting process that ensures a consistent reporting structure. A synthesis agent iteratively integrates visual and structured evidence through reasoning-driven verification to produce reliable and interpretable diagnostic outputs. Experimental evaluation on a public chest radiograph dataset demonstrates significant improvements over baseline vision-language models, achieving gains from 0.0493 to 0.3359 in BLEU-1, 0.0863 to 0.2440 in ROUGE-L, and 0.0829 to 0.1708 in METEOR, along with substantial improvements in semantic evaluation metrics such as Consistency (2.38 to 7.80) and Accuracy (2.34 to 6.93). The results highlight the effectiveness of structured multi-agent perception and reasoning for enhancing robustness, transparency, and automation in intelligent medical imaging systems, enabling integration into autonomous healthcare and robotic diagnostic workflows.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑