We report progress on the ongoing development of microcalorimeter detector technology for the Hot Universe Baryon Surveyor (HUBS) mission. We show the results from testing and characterizing selected pixels in a 10$\times$10 microcalorimeter array. The microcalorimeter is based on a Mo/Cu transition-edge sensor (TES) coupled to an Au absorber. To better understand the properties of the devices, we have first measured the energy resolution of a selected pixel in a TES array of the same design with a pulsed laser system that produces 3 eV photons, and found that individual photon peaks are easily resolved with the TES, indicating good performance. We have then exposed the microcalorimeter array to radiation from a $^{55}$Fe source, and found that the pixels tested show energy resolutions as good as 3.7$\pm$0.1 eV at 5.9 keV. The energy resolution is found to vary monotonically with the bias point for all the devices, showing little evidence for the presence of the so-called excess noise. This is consistent with the results from modeling the measured noise spectrum. The effects of thermal crosstalk are evident, leading to the degradation of energy resolution.
Resolve is a payload hosting an X-ray microcalorimeter detector operated at 50 mK in the X-Ray Imaging and Spectroscopy Mission (XRISM). It is currently under development as part of an international collaboration and is planned to be launched in 2023. A primary technical concern is the micro-vibration interference in the sensitive microcalorimeter detector caused by the spacecraft bus components. We conducted a series of verification tests in 2021-2022 on the ground, the results of which are reported here. We defined the micro-vibration interface between the spacecraft and the Resolve instrume…
Low-temperature detectors often use mechanical coolers as part of the cooling chain in order to reach sub-Kelvin operating temperatures. The microphonics noise caused by the mechanical coolers is a general and inherent issue for these detectors. We have observed this effect in the ground test data obtained with the Resolve instrument to be flown on the XRISM satellite. Resolve is a cryogenic X-ray microcalorimeter spectrometer with a required energy resolution of 7 eV at 6 keV. Five mechanical coolers are used to cool from ambient temperature to about 4 K: four two-stage Stirling coolers (STC)…
Optimising the multiplex factor of the frequency domain multiplexed readout of the TES-based microcalorimeter imaging array for the X-IFU instrument on the Athena Xray observatory
In the frequency-domain multiplexing (FDM) scheme, transition-edge sensors (TES) are individually coupled to superconducting LC filters and AC biased at MHz frequencies through a common readout line. To make efficient use of the available readout bandwidth and to minimize the effect of non-linearities, the LC resonators are usually designed to be on a regular grid. The lithographic processes however pose a limit on the accuracy of the effective filter resonance frequencies. Off-resonance bias carriers could be used to suppress the impact of intermodulation distortions, which nonetheless would …
Optimization and analysis of code-division multiplexed TES microcalorimeters
我们正在开发用于过渡边缘传感器阵列的码分复用(CDM)系统,目标是达到数百个复用因子。我们报告的X射线测量与四通道原型CDM系统,采用通量求和架构,强调数据分析问题。我们描述了一种经验方法来确定解调矩阵,最大限度地减少串扰。该CDM系统在5.9 keV下实现了2.3 eV和3.0 eV FWHM之间的能量分辨率。
The flight of the Micro-X sounding rocket on July 22, 2018 marked the first operation of Transition-Edge Sensors and their SQUID readouts in space. The instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia~A Supernova Remnant. While a rocket pointing malfunction led to no time on-target, data from the flight was used to evaluate the performance of the instrument and demonstrate the flight viability of the payload. The instrument successfully achieved a stable cryogenic enviro…
Uniform large transition-edge sensor (TES) arrays are fundamental for the next generation of X-ray space observatories. These arrays are required to achieve an energy resolution $ΔE$ < 3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently developing X-ray microcalorimeter arrays for use in future laboratory and space-based X-ray astrophysics experiments and ground-based spectrometers. In this contribution we report on the development and the characterization of a uniform 32$\times$32 pixel array with 140$\times$30 $μ$m$^2$ Ti/Au TESs with Au X-ray absorber. We re…
The Transition-Edge Sensor (TES) is an extremely sensitive device which is used to measure the energy of individual X-ray photons. For astronomical spectrometry applications, SRON develops a Frequency Domain Multiplexing (FDM) read-out system for kilopixel arrays of such TESs. Each TES is voltage biased at a specific frequency in the range 1 to 5 MHz. Isolation between the individual pixels is obtained through very narrow-band (high-Q) lithographic LC resonators. To prevent energy resolution degradation due to intermodulation line noise, the bias frequencies are distributed on a regular grid. …
Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer
Université de Toulouse(图卢兹大学);CNRS(法国国家科学研究中心);IRAP(天体物理研究所);Université de Genève(日内瓦大学);Università degli Studi di Palermo(巴勒莫大学);INAF/Osservatorio Astronomico di Palermo G.S.Vaiana(意大利国家天体物理研究所巴勒莫天文台);CNES(法国国家空间研究中心);Istituto di Astrofisica e Planetologia Spaziali(天体物理学与行星物理学研究所);SRON, Netherlands Institute for Space Research(荷兰空间研究所);Lawrence Livermore National Laboratory(劳伦斯利弗莫尔国家实验室);NASA/Goddard Space Flight Center(美国宇航局戈达德太空飞行中心)
The X-IFU (X-ray Integral Field Unit) onboard the large ESA mission Athena (Advanced Telescope for High ENergy Astrophysics), planned to be launched in the mid 2030s, will be a cryogenic X-ray imaging spectrometer operating at 55 mK. It will provide unprecedented spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) in the 0.2-12 keV energy range thanks to its array of TES (Transition Edge Sensors) microcalorimeters of more than 2k pixel. The detection chain of the instrument is developed by an international collaboration: the detector array by NASA/GSFC, the cold electroni…
We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalorimeters. In our FDM scheme, TESs are AC-biased at different resonant frequencies in the low MHz range through an array of high-$Q$ LC resonators. The current signals of all TESs are summed at superconducting quantum interference devices (SQUIDs). We have demonstrated multiplexing for a readout of 31 pixels using room temperature electronics, high-$Q$ LC filters and TES arrays developed at SRON, and SQUID arrays from …
Opening the low-background and high-spectral-resolution domain with the ATHENA large X-ray observatory: Development of the Cryogenic AntiCoincidence Detector for the X-ray Integral Field Unit
Microcalorimeters have demonstrated success in delivering high spectral resolution, and have paved the path to revolutionary new science possibilities in the coming decade of X-ray astronomy. There are several research areas in compact object science that can only be addressed with energy resolution Delta(E)<~5 eV at photon energies of a few keV, corresponding to velocity resolution of <~a few hundred km/s, to be ushered in by microcalorimeters. Here, we review some of these outstanding questions, focusing on how the research landscape is set to be transformed (i) at the interface between accr…
The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which works in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonstration Models, performed in a FDM setup. We show that it is possible to operate properly both detectors, and we provide a preliminary demonstration of the anti-coincidence capability of the system ach…
Micro-X is an X-ray sounding rocket payload that had its first flight on July 22, 2018. The goals of the first flight were to operate a transition edge sensor (TES) X-ray microcalorimeter array in space and take a high-resolution spectrum of the Cassiopeia A supernova remnant. The first flight was considered a partial success. The array and its time-division multiplexing readout system were successfully operated in space, but due to a failure in the attitude control system, no time on-target was acquired. A re-flight has been scheduled for summer 2022. Since the first flight, modifications hav…
Large format arrays of transition edge sensor (TES) are crucial for the next generation of X-ray space observatories. Such arrays are required to achieve an energy resolution of $\mathrmΔE<$3 eV full-width-half-maximum (FWHM) in the soft X-ray energy range. We are currently developing X-ray microcalorimeter arrays as a backup option for the X-IFU instrument on board of ATHENA space telescope, led by ESA and foreseen to be launched in 2031. In this contribution, we report on the development and the characterization of a uniform 32$\times$32 pixel array with (length$\times $width) 140$\times$30 …